Flow Meter

Leading Wholesale Trader of avfm 6.1 area velocity flow meter, portable doppler flow meter 6.1, slt 5.0 level & flow monitor, ttfm 6.1 transit time ultrasonic flow meter, flowcert and mdot thermal mass flowmeter from Indore.

AVFM 6.1 Area Velocity Flow Meter

Request Callback

₹ 516000 / Piece Get Latest Price

Product Brochure
BrandPulsar / Greyline
Application MediaWater
Power Supply10 W maximum
AccuracyLevel: +-0.25% of reading or +-0.08", whichever is greater. Repeatability & Linearity 0.1%.
Electronics EnclosureNEMA4X (IP 66) polycarbonate with clear, shatterproof cover
Frequency50/60 Hz
Voltage100-240 V
Channel TypesRound pipe, rectangular, trapezoid, egg or custom shapes
DisplayWhite, back-lit matrix - displays flow rate, totalizer, relay states, operating mode and calibration
ProgrammingBuilt-in 5-key calibrator with English, French or Spanish language selection
Power Input100-240V AC 50-60Hz, 10VA maximum. Optional: 9-32V DC, 10 W maximum
Outputs3 Isolated 4-20mA, 1000 ohm, (Flow, Level and Velocity) or 0-5VDC by menu selection
Control Relays2 Relays, form 'C' dry contacts rated 5 amp SPDT; programmable for flow proportional pulse
Data LoggingProgrammable 26 million point data capacity, time and date stamped plus formatted flow reports
Operating Temp.-20 DegreeC to 60 DegreeC (-5 DegreeF to 140 DegreeF)
Approximate Shipping Weight10 Lbs. (4.5 Kg)
ApprovalsCE, CSA/UL/EN 61010-1
The Area Velocity Flow Measurement method is the most common method of all flow measurements. The AVFM 6.1 Area Velocity Flow Meter uses a submersible ultrasonic sensor measuring both the level and velocity of flowing liquid to calculate flow measurement in an open channel or pipe. The sensors are mounted either inside a pipe or at the bottom of a channel, and the sensor is built to resist fouling, corrosion, and abrasion. The AVFM 6.1 Area Velocity Flow Meter can be configured with the standard submerged velocity-level sensor or with submerged velocity in combination with a separate non-contacting ultrasonic level sensor, which is suitable for highly aerated fluids or those with a high concentration of suspended solids.                                FEATURES                                                  
  •  No flume or weir required – submersible ultrasonic sensor measures velocity and level simultaneously to calculate flow. No moving parts to wear, foul, or clog.
  •  The built-in 5-button keypad, intuitive menu, and large backlit LCD display make the AVFM 6.1 the most operator-friendly area-velocity flow meter on the market.
  •  Fast, simple, installation and set-up.
  •  Improved performance in a wider range of operating conditions.
  •  At a glance, view flow rate, velocity, level, totalizer, relay status, and important diagnostic information on the LCD display.
  •  Three isolated 4-20 mA outputs for flow rate, velocity, and level, and two relay outputs for pulse output or alarm.
  • 6.5 million point data logger for greater flexibility of data monitoring, control, and reporting.
  •  Min, Max, and Total Flow data from the last 365 days is available on the LCD display, or download directly to a USB for easy reporting.
  •  Monitors flow rate, volume total, run hours, and diagnostic information through only two wires with the optional Modbus RTU serial communication output.

Portable Doppler Flow Meter 6.1

Request Callback

₹ 672500 / Piece Get Latest Price

Product Brochure
Flow Rate Range ±0.03 m/s to 12.2 m/s (±0.1 ft/s to 40 ft/s) in most applications
Flow Rate Range Ultrasonic Sensor mounts on any pipe from 12.7 mm to 4.6 m ID (0.5 in to 15 ft)
Display Color TFT LCD Display, IPS type, 2.8" screen size, 320 x 240 resolution, 500 NITS brightness, super wide view
Power Input

Built-in rechargeable lithium polymer battery for up to 15 hours continuous operation

External mains to USB-C charger with 100-240V AC 50-60 Hz, 0.6A input; and 5.0V DC, 3A, 15W output

Outputs Log files, daily log files, parameter settings files, and waveform capture files via USB-C flash drive (included)
Data Logger 12 million point capacity, configurable for velocity or flow rate, date and time stamped, configurable format for Greyline Logger Software (LG2) or CSV, available intervals of 10 s, 30 s, 1 min, 2 min, 5 min, 10 min, 15 min, 30 min, and 1 hr
PC Software Free Greyline Logger Software for Windows. For display, manipulation, analysis, and exporting of data.
Operating Temperature (Electronics) -20 °C to +60 °C (-5 °F to +140 °F)
Electronics Enclosure IP67 when transducer cables connected. IP65 when transducer cables not connected. Aluminum enclosure with silicone protective end covers.
Carry Case IP67 with protective molded foam with room for transducer and installation hardware
Accuracy ±2% of reading or 0.03 m/s (0.1 ft/s), whichever is greater. Requires solids or bubbles minimum size of 100 microns, minimum concentration 75 ppm. Repeatability: ±0.1%, Linearity ±0.5%
Calibration Built-in 5-button keypad interface. Optional user-configured password protection.
Language Selection English, French, Spanish

SLT 5.0 Level & Flow Monitor

Request Callback

Get Latest Price

Product Brochure
MaterialPlastic Body
Application MediaWater
Usage/ApplicationAutomotive
Power Supply100-240VAC
ColorBlue
Accuracy+-0.25% of Range or 2 mm (0.08") whichever is greater, Repeatability and Linearity: +-0.1%
Electronics EnclosureWatertight and dust tight NEMA4X (IP 66) polycarbonate with clear, shatterproof cover
Flow RangeLevel, Range or Open Channel Flow
Frequency50-60 Hz
Voltage440 V
Operating Temp.-5 Degree to 140 DegreeF (-20 Degree to 60 DegreeC)
Weight10 lbs. (4.5 kg)
  • Non-contact measurement of level or open channel flow
  • ±0.25% of Range or 2mm (0.08in) accuracy
  • Repeatability and Linearity: ±0.1%
  • Simple 5-key calibration
  • Isolated 4-20mA output
  • Programmable control relays
  • NEMA4X (IP66) polycarbonate enclosure
    • Watertight & dust tight with shatterproof cover
  • False echo rejection
  • 2 programmable control relays (upgradeable to 6)
  • Electrical surge protection
  • Intrinsically safe sensor option
  • Plug and play relay and data logger options

TTFM 6.1 Transit Time Ultrasonic Flow Meter

Request Callback

₹ 455000 / Piece Get Latest Price

Product Brochure
BrandPulsar / Greyline
Flow Media TypeWater
Usage/ApplicationAutomotive
DisplayDigital
Model Name/NumberTTFM 6.1
Power Supply10 W maximum
Accuracy+-1% of reading from 0.46 m/s to 12.2 m/s (1.5 ft/s to 40 ft/s); +-0.0046 m/s (+-0.015 ft/s)
Electronics EnclosureNEMA4X (IP 66) polycarbonate with clear, shatterproof cover
Frequency50/60 Hz
Voltage100-240 V
Operating ParametersFor clean liquids in full pipes with less than 2% solids or gas bubbles
ProgrammingBuilt-in 5-button keypad with English, French and Spanish menu language selection
TTFM DisplayWhite, backlit matrix - displays 5-digit flow rate with floating decimal,14-digit totalizer
Analog OutputIsolated 4-20mA / 0-5V, 1000 ohm load maximum
Control Relays2 Relays, form 'C' dry contacts rated 5 amp SPDT; programmable flow alarm and/or flow proportional
Data LoggerBuilt-in 128MB data logger with USB output and Windows(TM) software. Capacity for approx. 26 million
Operating Temp.-20 DegreeC to 60 DegreeC (-5 DegreeF to 140 DegreeF)
Approximate Shipping Weight12 lbs. (5.5 kg)
ApprovalsCE, CSA/UL/EN 61010-1
Flow Velocity Range+-0.02 m/s to 12.2 m/s (+-0.07 ft/s to 40 ft/s)
Power Input100-240 V AC 50/60 Hz, 10 VA maximum Optional: 9-32 V DC, 10 W maximum
 Description                                                The TTFM 6.1 Transit-Time Flow Meter is ideal for treated clean water, raw water, cooling water, chemicals, hydraulic oil, low-conductivity water, water/glycol solutions, and diesel and fuel oils. The unit works by measuring the time-of-flight difference for ultrasonic sound pulses transmitted from one transducer to another. The time between transmitted and received signals is measured by the flow meter. Mount the TTFM 6.1 Transit-Time Flow Meter ultrasonic transducers on the outside of a pipe and use the built-in 5-button keypad to enter the pipe material, outer diameter, wall thickness, and fluid type. The TTFM 6.1 will display the correct transducer separation distance and mounting method.                                        Features                                                     
  • Three easy-to-select transducer options covering 15 mm to 1,200 mm nominal pipe diameters.
  • Transducers work on all common pipe materials.
  • Standard mounting hardware makes novice installers look like experts.
  • Transducers simply strap to the outside of the pipe, meaning no wear and tear, and no shutdown to install.
  • Easy-to-contact and knowledgeable staff is here to help you before, during, and after installation.
  • Analog, pulse, and serial communication options to meet your specific application needs.
  • Standard 26 million point data logger and free Logging Software make data management and reporting fast and easy.
  • All transducers are approved for use in hazardous locations.
             

FlowCERT

Request Callback

₹ 244000 / Piece Get Latest Price

Product Brochure
Supply115 V AC +5% / - 10%, 230 V AC +5% / - 10% 50/60 Hz, 22-28 V DC, 10 W maximum power (typically 6 W)
Weight1 kg (2.2 lbs)
Cable Entry Detail10 cable entry knock outs, 1 x M16, 5 x M20 underside, 4 x 18 mm dia (PG11) at rear
IP RatingIP65/NEMA 4X

Minimum order quantity: 1 Piece

Controller Body Dimensions:235 mm x 184 mm x 120 mm (9.25 in x 7.24 in x 4.72 in)Weight: 1 kg (2.2 lbs) Cable Entry Detail: 10 cable entry knock outs, 1 x M16, 5 x M20 underside, 4 x 18 mm dia (PG11) at rearMaximum Separation: Up to 1,000 m (3,280 ft)IP Rating: IP65/NEMA 4XMax. and Min Tempeterature (Electronics):-20 °C to +50 °C (-4 °F to +120 °F)Power Supply: 115 V AC +5% / - 10%, 230 V AC +5% / - 10% 50/60 Hz, 22-28 V DC, 10 W maximum power (typically 6 W)On Board Programming: Via Integral Keypad Programming Security: Via passcode (user selectable and adjustable)

MDot Thermal Mass Flowmeter

Request Callback

₹ 265000 / Piece Get Latest Price

Product Brochure

Minimum order quantity: 1 Piece

Probe Diameter:

3/4 inch

Sensor Material:

316 stainless steel

Enclosure:

NEMA 4X (IP67), aluminum, dual 3/4 inch FNPT conduit entries

Performance Specifications


Flow Accuracy:

Air: ±1% of reading ±0.2% of full scale

Other gases: ±1.5% of reading ±0.5% of full scale

Accuracy specification applies to customer's selected flow range

Unobstructed Pipe Requirement:

Insertion: 15 diameters upstream, 5 diameters downstream
Inline: 8 diameters upstream, 4 diameters downstream
Flow Repeatability:

±0.2% of full scale

Flow Response Time:

0.8 seconds (one time constant)

Temperature Accuracy:

±0.6° C (±1° F)

Calibration:

Factory calibration to NIST-traceable standards

MDot Max Cal:

In-situ, operator initiated calibration validation

X

Contact Us

S.P. Singh (Director)
Jeskon Systems Private Limited
P-9, Sukhliya, Near Community Hall
Indore - 452001, Madhya Pradesh, India

Get Directions
Send Email
Share: