Call 08048600851 53% Response Rate

our range

Ultrasonic FlowMeters Level Industrial Instruments

We are a leading Wholesale Trader of portable doppler flow meter 5.1 pdfm, ultrasonic level and flow monitor, ptfm 6.1 portable transit time flow meter, transit time flow meter, portable transit time flow meter and portaflow pt400 portable transit time flow meter from Indore, India.
  • Portable Doppler Flow Meter 5.1 PDFM
  • Portable Doppler Flow Meter 5.1 PDFM
  • Portable Doppler Flow Meter 5.1 PDFM
  • Portable Doppler Flow Meter 5.1 PDFM
  • Portable Doppler Flow Meter 5.1 PDFM
  • Portable Doppler Flow Meter 5.1 PDFM
  • Portable Doppler Flow Meter 5.1 PDFM
  • Portable Doppler Flow Meter 5.1 PDFM
  • Portable Doppler Flow Meter 5.1 PDFM
Portable Doppler Flow Meter 5.1 PDFM

Portable Doppler Flow Meter 5.1 PDFM

Rs 3.25 Lakh  / PieceGet Best Price

Product Brochure

BrandPulsar / Greyline
Model Name/NumberPDFM 5.1
Flow Media TypeWater
Flow Range+-0.46 m/s to 12.2 m/s (+-0.125 ft/s to 40 ft/s) in most applications
DisplayWhite, backlit matrix - displays flow rate, totalizer, operating mode and calibration menu
Accuracy+-2% of reading or 0.1 ft/sec (0.03 m/sec). Requires solids or bubbles minimum size of 100 microns
Frequency50/60 Hz
Voltage100-240 V
Carry CaseRated IP67 with protective molded foam insert
Approvals:Charger is CE and UL approved. The PDFM 5.1 is not certified for use in hazardous rated locations
Language SelectionEnglish,French,Spanish
Electronics EnclosurePortable,ABS enclosure
Electronics Operating Temperature-10 Degree to 140 DegreeF (-23 Degree to 60 DegreeC)
SensitivityAdjustable cut-off,Damping adjustable
Outputs4-20mA (500 ohm) when AC powered USB for Data Log transfer by direct PC connection
Pipe SizeUltrasonic Sensor mounts on any pipe from 1/2'' to 180'' ID (12.5 mm to 4.5 m)
Power InputBuilt-in NiMH battery for up to 18 hours continuous operation External charger with 100-240VAC

The Greyline Instruments, by Pulsar Measurement, PDFM 5.1 doppler flow meter is fast and easy to operate making it ideal for flow troubleshooting, balancing and checking performance of permanent flow meters. The non-contact sensor quickly attaches to the outside of a pipe while the built-in keypad and calibration menu let you set up the instrument in minutes. Use the PDFM 5.1 for projects where a permanent flowmeter is not required or to temporarily replace installed flow transmitters.

The PDFM 5.1 non-intrusive Doppler ultrasonic sensor works with pipes from 1/2" to 180" in diameter. An acoustic pulse is reflected back to the sensor from particles or gases in the flowing liquid. The flow rate of any fluid can be measured as long as it contains air bubbles or solids. It is ideal for wastewater, slurries, sludge, and most chemicals, acids, caustics, and lubrication fluids. The system works with most metal and plastic pipes including PVC, ductile iron, carbon steel and stainless steel.

The PDFM 5.1 is AC/DC powered with built-in NiMH batteries and external charger. With its 4-20mA output you can use the PDFM 5.1 as a spare transmitter in critical applications. For flow studies and troubleshooting, use the built-in 300,000 point data logger. Data logs can be retrieved with the data logging software. Simply connect the USB output directly to your PC or Laptop to download data logger files.



Additional Information:

  • Item Code: PDFM-5.1

View Complete details

get quote request a call back
  • Ultrasonic Level and Flow Monitor
  • Ultrasonic Level and Flow Monitor
  • Ultrasonic Level and Flow Monitor
  • Ultrasonic Level and Flow Monitor
Ultrasonic Level and Flow Monitor

Ultrasonic Level and Flow Monitor

Rs 3.25 Lakh  / PieceGet Best Price

Product Brochure

DisplayWhite,backlit matrix displays flow rate,totalizer,relay status,operating mode and calibration menu
Operating Temperature-5 deg to 140 deg F (-20 deg to 60 deg C)
Accuracy+/-0.25% of Range or 2 mm (0.08'') whichever is greater, Repeatability and Linearity +/-0.1%
OutputIsolated 4-20mA, 1000 ohm load maximum, programmable offset
Electronics EnclosureWatertight and dust tight NEMA4X (IP 66) polycarbonate with clear, shatterproof cover
Electrical Surge ProtectionSensor, 4-20mA and AC power input
ProgrammingBuilt-in 5-key calibrator with English, French or Spanish language selection
Operating ModesLevel, Range or Open Channel Flow
Approximate Shipping Weight10 lbs. (4.5 kg)
Power Input100-240VAC 50-60Hz (see Options), 2.4-5.6 Watts depending on options
Description:
  • Use this versatile instrument to continuously measure, display, transmit and control liquid level in storage tanks and pumping stations, or to monitor and totalize Open Channel Flow through any flume or weir. Mount the non-contacting ultrasonic sensor above the liquid being measured and install the watertight electronics enclosure nearby. Features a user-friendly keypad calibration system, backlit LCD display, an isolated 4-20mA output and 2 programmable control relays.
  • Calibration is easy with the built-in 5 button keypad. The SLT 5.0 offers simple menu selection of measurement units (gallons, liters etc.), calculates volume in horizontal round tanks, or flow rate (and total) through any flume or weir.
  • For hazardous locations, the ultrasonic sensor is rated Intrinsically Safe with an optional safety barrier. The standard PVC and Teflon Sensor is rated for measurement ranges up to 32 ft/10 m, or select optional sensors for flange-mount or applications requiring longer measurement range. Options include 4 additional control relays (6 total) and a built-in 2-million point Data Logger with USB output to Flash memory sticks.

Features:
  • Measure Level or Open Channel Flow
  • User-Friendly Calibration System
  • Isolated 4-20mA (1000 ohm)
  • False Echo Rejection
  • 2 Programmable Control Relays
  • Electrical Surge Protection
  • Intrinsically Safe Sensor Option
  • Plug and Play Relay and Data Logger Options

Other Details:
  • Use it for Level: Specify SLT 5.0 for inventory monitoring and level control of chemicals, wastewater, viscous or corrosive liquids. Built-in control relays are programmable for pump control, pump alternation and level alarms. 
  • Use it for Flow: Displays, transmits and totalizes wastewater flow through any flume or weir. Features a simple, password protected calibration system, automatic totalizer and flow proportionate control relays. 
  • No maintenance Sensor: Each SLT 5.0 includes a non-contacting ultrasonic sensor which mounts above the material being measured. There is no contact and no moving parts. The sensor is sealed to withstand accidental submersion and rated for hazardous locations with optional intrinsic safety barrier.



Additional Information:

  • Item Code: SLT-5.0

View Complete details

get quote request a call back
  • PTFM 6.1 Portable Transit Time Flow Meter
  • PTFM 6.1 Portable Transit Time Flow Meter
  • PTFM 6.1 Portable Transit Time Flow Meter
  • PTFM 6.1 Portable Transit Time Flow Meter
  • PTFM 6.1 Portable Transit Time Flow Meter
  • PTFM 6.1 Portable Transit Time Flow Meter
  • PTFM 6.1 Portable Transit Time Flow Meter
PTFM 6.1 Portable Transit Time Flow Meter

PTFM 6.1 Portable Transit Time Flow Meter

Price on Request

Product Brochure

BrandPulsar / Greyline
Model Name/NumberPTFM 6.1
Flow Media TypeWater
Flow Range+-0.03 m/s to 12.2 m/s (+-0.1 to 40 ft/s)
DisplayDigital
Power Supply15W
Accuracy- +-1% of reading or +-0.0046 m/s (+/- 0.015 ft/s), whichever is greater - Repeatability & Linearity:
Electronics EnclosureIP67 when transducer cables connected. IP65 when transducers cables not connected. Aluminum enclosur
Frequency50-60Hz
Voltage100-240V
PTFM DisplayColor TFT LCD display, IPS type, 2.8" screen size, 320 x 240 resolution, 500 NITS brightness, super
Power Input- Built-in rechargeable lithium polymer battery for up to 15 hours continuous operation - External m
Carry CaseIP67, with protective molded foam, with room for all transducer sizes and installation hardware
Data Logger12 million point capacity, configurable for velocity or flow rate, date and time stamped, configurab
Language SelectionEnglish, French, Spanish
Operating ParametersFor clean fluids in full pipes, with typically less than 2% by-volume concentration of solids or bub
Approximate Shipping Weight5.5 kg (12 lb)
PC SoftwareFree Greyline Logger Software for Windows. For display, manipulation, analysis, and exporting of dat
Operating Temp-20 DegreeC to +60 DegreeC (-5 DegreeF to +140 DegreeF)
ConfigurationBuilt-in 5-button keypad interface with English, French, and Spanish menu language selection
ApprovalsCE
OutputsLog files, daily log files, parameter settings files, and waveform capture files via USB-C flash dri
Whether you need flow measurement when you didn’t have it before, or you need to prove that your existing system is performing properly, the PTFM 6.1 Portable Transit Time Flow Meter is here to help by providing accurate, non-invasive flow measurement in the most challenging industrial environments and applications, with minimal installation complexity and cost.With new and more powerful signal processing hardware, rugged IP67 design, and three interchangeable, non-invasive transducer sizes optimized for a wide range of pipe sizes and materials, the PTFM 6.1 is the right choice for your on-the-go or long-term flow measurement applications.

View Complete details

get quote request a call back
  • Transit Time Flow Meter
  • Transit Time Flow Meter
  • Transit Time Flow Meter
  • Transit Time Flow Meter
  • Transit Time Flow Meter
  • Transit Time Flow Meter
  • Transit Time Flow Meter
  • Transit Time Flow Meter
  • Transit Time Flow Meter
Transit Time Flow Meter

Transit Time Flow Meter

Rs 3.25 Lakh  / PieceGet Best Price

Product Brochure

Operating Temperature-5 deg to 140 degF (-20 deg to 60 degC)
Accuracy+/-1% of reading from 1.5 to 40 ft/sec (0.5 to 12.0 m/sec) and +/-0.015 ft/sec (+/-0.0046 m/sec) for
Analog outputIsolated 4-20mA / 0-5V, 1000 ohm load maximum, programmable offset
Operating ParametersFor clean liquids in full pipes with less than 2% solids or gas bubbles
ApprovalCE, CSA/UL/EN 61010-1
Electronics EnclosureWatertight and dust tight NEMA4X (IP 66) polycarbonate with clear, shatterproof cover
Approximate Shipping Weight12 lbs. (5.5 kg)
ProgrammingBuilt-in 5-button keypad with English, French and Spanish menu language selection
Power Input100-240 V AC 50-60 Hz, 10 VA maximum,Optional 9-32VDC, 10 Watts maximum
Description:
  • Accurately measure the flow rate of relatively clean, non-aerated liquids like potable water, raw water, cooling water, de-ionized or reverse-osmosis water, oils and chemicals in full pipes. Ultrasonic transducers mount on the outside of a pipe without shutting down flow. Flow rate is displayed on the large, backlit display, along with total volume, signal strength, relay status, and other diagnostic values. Use the built-in control relays as flow alarms or volume totalization. Connect the isolated 4-20mA output to PLC's or controllers. A 128MB data logger is standard, capable of capturing up to 26 million data points. Optional MODBUS RTU via RS-485 available for connection to automation systems.
  • The TTFM 6.1 works on a wide range of pipe sizes and materials including carbon steel, stainless steel, ductile iron, concrete lined ductile iron, cast iron, PVC, PVDF, fiberglass, copper, brass, aluminum and pipes with bonded liners including epoxy, rubber and Teflon.
  • The TTFM 6.1 Transit Time Flow Meter operates by measuring the “transit time” or “time of flight” for ultrasonic sound pulses transmitted from one transducer to another. Depending on the mounting configuration, the signal may cross the pipe once, twice or four times. To measure flow the transit time is compared between ultrasonic signals travelling upstream and downstream.

TTFM 6.1 Standard Features Include:
  • Enhanced Performance
  • Wide Range of Applications
  • Easy to Install and Configure
  • Non-Contacting Clamp-on Ultrasonic Transducers
  • Works on a Large Variety of Pipe Materials and Sizes
  • Large Backlit Flow Rate Display and Totalizer
  • Isolated 4-20mA Output
  • 2 Programmable Control Relays
  • Optional MODBUS® RTU or HART Output
  • Application Optimization Available
  • 128MB Data Logger
  • Plug-and-play options including MODBUS RTU output and extra control relays
  • Programming built-in 5-button keypad

Specifications:Scope: 
  • This specification covers a Clamp-On Transit-Time Ultrasonic Flow Meter as manufactured by Greyline Instruments, Largo, Florida / Long Sault, Ontario. The meter shall provide for non-intrusive flow measurement, direction indication, volume totalizing, and transmitting of the flow rate in a full pipe.

Performance Specifications:
  • The ultrasonic flow meter shall have an accuracy of ±1% of reading or ±0.015 ft/sec (±0.0046 m/sec), whichever is greater. Have repeatability and linearity of ±0.25%.
  • Shall operate on relatively clean liquids in full pipes with less than 2% solids or gas bubbles at flow velocities from ±0.07 to 40 ft/sec (±0.02 to 12 m/sec).
  • Operate on any metal, or plastic, sonic conducting material including carbon steel, stainless steel, ductile iron, concrete lined ductile iron, cast iron, PVC, PVDF, fiberglass, galvanized steel, copper, brass and pipes with bonded liners including epoxy, rubber and Teflon.
  • The ultrasonic flow meter shall be optimized and pre-programmed for the application when information like pipe material, pipe size, wall thickness, fluid type, fluid temperature, and max flow rate are provided at time of order.

Transducers (Flow Sensors):
  • The flow meter shall have a dual transmitting/receiving, clamp-on transducers.
  • The transducers shall operate continuously at temperatures from -40°F to 300°F (-40°C to 150°C).
  • The standard transducer pair shall be designed to install on pipes with inside diameter ranging from 2" to 48" (50 mm to 1200 mm).
  • Have 25 ft (7.6 m) length triaxial cables from the electronics with BNC connectors to transducers.


      Additional Information:

      • Item Code: TTFM6.1

      View Complete details

      get quote request a call back
      • Portable Transit Time Flow Meter
      • Portable Transit Time Flow Meter
      • Portable Transit Time Flow Meter
      Portable Transit Time Flow Meter

      Portable Transit Time Flow Meter

      Rs 3.25 Lakh  / PieceGet Best Price

      Product Brochure

      Operating Temperature-5 deg to 140 deg F (-20 deg to 60 deg C)
      ApprovalsAC Charger is CE and UL approved
      Accuracy+/- 1% of reading or 0.1 ft/sec (0.03 m/sec), whichever is greater
      Approximate Shipping Weight12 lbs. (5.5 kg)
      Electronics EnclosurePortable, ABS
      Power InputBuilt-in NiMH battery for up to 18 hours continuous operation External charger with 100-240VAC
      Operating ParametersFor clean liquids in full pipes with less than 2% solids or gas bubbles
      Outputs4-20mA (500 ohm) when powered by AC adapter
      Repeatability and Linearity+/- 0.25%
      Description:
      • Recommended for fluids like water, glycol, oils and chemicals. Use it for calibrations, troubleshooting, flow surveys and as a temporary transmitter to replace inline flowmeters.
      • The PTFM 1.0 ultrasonic transducers clamp-on the outside of pipes from 2" to 48" (50 to 1200 mm) diameter. The ultrasonic signal works through common pipe materials including carbon steel, stainless steel, ductile iron, cast iron, PVC, PVDF, fiberglass, copper, brass, aluminum and pipes with bonded liners including epoxy, rubber and Teflon. Transducers can be mounted without shutting down flow and there is no obstruction or pressure drop. It measures and totalizes forward and reverse flow.
      • The PTFM 1.0 Portable Transit Time Flow Meter operates by measuring the “transit time” or “time of flight” for ultrasonic sound pulses transmitted from one transducer to another. Depending on the mounting configuration the signal may cross the pipe once, twice or four times. To measure flow the transit time is compared between ultrasonic signals travelling upstream and downstream.

      Features:
      • Non-Contacting Clamp-on Ultrasonic Transducers Works on Metal and Plastic Pipes
      • Large Backlit Flow Rate Display and Totalizer
      • Isolated 4-20mA Output
      • Built-in 5-Key Calibrator
      • 300,000 point data logger

      User-Friendly Operating System:
      • Calibration is easy with the onscreen menu system. Just enter the pipe diameter, wall thickness and pipe material. The PTFM 1.0 is powered by an internal, rechargeable NiMH battery or can be operated continuously with AC power adapter. Each PTFM 1.0 includes a watertight carry case, transducer set, cables and mounting clamps.

      Built-in Data Logger with Windows Software Included:
      • Set up the 300,000 point data logger to store time and date-stamped flow readings from 10 second to 5 minute intervals. View the convenient on-screen 'Flow Report' where total, minimum, maximum and average flow rates are stored in a 24 hour daily summary.
      • Transfer flow logs to your PC or laptop through the PTFM 1.0's USB output. Greyline Logger software (included) displays data in both graph and table formats with one-click export to Microsoft Excel®, images or CSV files for use in other programs.

      Portable Ultrasonic Flow Meter Specifications:Scope:
      • This specification covers a portable, ultrasonic Transit Time flow meter by Greyline Instruments, Largo, Florida / Long Sault, Ontario. This portable instrument shall provide for non-intrusive flow measurement, indication, totalizing and transmitting of the flow rate in a full pipe.

      General:
      • Each portable Transit Time flow meter shall have the following design features and engineering specifications:

      Performance Specifications:
      • The ultrasonic flow meter shall have an accuracy of ±1% of reading or 0.1 ft/sec (0.03 m/sec), whichever is greater. Have repeatability and linearity of ±0.25%.
      • Shall operate on clean liquids in full pipes with less than 2% solids or gas bubbles at flow velocities from ±0.07 to 39 ft/sec (±0.02 to 12 m/sec).
      • Operate on the following pipe materials: carbon steel, stainless steel, PVC, PVDF, fiberglass, galvanized steel, mild steel, ductile iron, glass, copper, brass and pipes with bonded liners including cement, epoxy, rubber and Teflon.
      • Operate on AC power or from internal, rechargeable batteries.

      Transducers:
      • The flow meter shall have a dual transmitting/receiving, clamp-on transducers operating at 1.28MHz.
      • The transducers shall operate continuously at temperatures from -40°F to 300°F (-40°C to 150°C).


      Additional Information:

      • Item Code: PTFM-1.0

      View Complete details

      get quote request a call back
      • Portaflow PT400 Portable Transit Time Flow Meter
      • Portaflow PT400 Portable Transit Time Flow Meter
      • Portaflow PT400 Portable Transit Time Flow Meter
      • Portaflow PT400 Portable Transit Time Flow Meter
      • Portaflow PT400 Portable Transit Time Flow Meter
      • Portaflow PT400 Portable Transit Time Flow Meter
      • Portaflow PT400 Portable Transit Time Flow Meter
      • Portaflow PT400 Portable Transit Time Flow Meter
      • Portaflow PT400 Portable Transit Time Flow Meter
      Portaflow PT400 Portable Transit Time Flow Meter

      Portaflow PT400 Portable Transit Time Flow Meter

      Rs 3.25 Lakh  / PieceGet Best Price

      Product Brochure

      Accuracy+/-2% of reading in most applications
      Repeatability+/-0.5%
      Outputs0/4-20mA, 5V pulse (1 pulse/sec maximum)
      Data LoggerNot available (see model PT500)
      Carry CasePolypropylene with protective molded foam insert
      Electronics EnclosureRated IP54, ABS portable
      Fluid ApplicationRecommended for clean liquids with less than 2% solids or gas bubbles
      Flow Rate Range0.65 to 40 ft/sec (0.2 to 12 m/sec)
      Pipe Wall Thickness0.039 - 2.95'' (1 - 75 mm)
      Pipe Size'A' Transducers - 0.51'' to 4.5'' Outside Diameter (13 mm to 115 mm)
      Totalizer12 digits - displays separate forward and reverse flow totals
      Description:
      • Recommended for clean fluids like water, glycol, oil and most chemicals. Sensors can be mounted without shutting down flow and there is no obstruction or pressure drop. The ultrasonic signal travels through all common metal and plastic pipe materials. Flow rate and totalizer are displayed continuously along with battery status, signal strength. Press one key to instantly change the units of flow measurement (e.g. from gallons to liters). Real time flow can be displayed in large numeric values or as a graph.
      • Portaflow calibration is easy with the onscreen menu system. Enter the pipe diameter, wall thickness and pipe material, and the PT400 calculates the optimum mounting method and separation distance for the sensors.
      • The Portaflow PT400 ultrasonic sensors clamp on the outside of vertical or horizontal pipes. Select a Sensor pair for the range of pipe sizes you will monitor:

      Select a Sensor pair for the range of pipe sizes you will monitor:
      • Transducers for 0.51" to 4.5" Outside Diameter (13 to 115 mm) or Transducers for 2” to 39.37” Outside Diameter (50 to 1000 mm)
      • Calibration parameters can be stored for up to twenty different sites so that operators can recall calibration setups from the Portaflow memory. Use the 5V pulse or 4-20 mA output to transmit to external devices like data loggers or recorders. The P400 includes 'A' or 'B' sensor pairs, stainless steel guide rail and mounting clamps, sensor cables, coupling compound and AC charger with a rugged polypropylene carry case. It operates up to 16 hours from internal batteries and recharges overnight.

      Features:

      • Clamp-on Ultrasonic Sensors
      • Choose Small Pipe or Large Pipe Sensors
      • Internal Battery and/or AC Powered
      • Easy Calibration and Set-up
      • Flow Proportionate Pulse Output
      • 4-20 mA Output

      Portable Ultrasonic Flow Meter Specifications:Scope:
      • This specification covers a portable, ultrasonic Transit Time flow meter by Greyline Instruments, Largo, Florida / Long Sault, Ontario. This portable instrument shall provide for non-intrusive flow measurement, indication, totalizing and transmitting of the flow rate in a full pipe.

      General:
      • Each portable Transit Time flow meter shall have the following design features and engineering specifications:

      Performance Specifications:Have an accuracy of ±2% of reading in most clean fluid applications. Have repeatability of ±0.5%.
      • Operate on clean liquids in full pipes with less than 2% solids or gas bubbles.
      • Operate on any sonic conducting pipe material such as carbon steel, stainless steel, galvanized steel, mild steel, copper, UPVC, PVDF, glass, brass and including pipes with bonded liners of epoxy, rubber or cement.
      • Operate on AC/DC power. Include an internal NiMH rechargeable battery with capacity for 16 hours continuous battery operation. Recharge and operate with power input of 100-260VAC 50-60Hz.
      • Ultrasonic Transducers:
      • Have a dual 2 MHz transmitting/receiving, clamp-on transducers.
      • The transducers shall be waterproof and operate continuously at temperatures from -4°F to 275°F (-20°C to 135°C).
      • The transducers shall be designed to install on pipes with inside diameter ranging from 0.51" to 4.5" OD (13 mm to 115 mm).
      • Have a 6 ft (2 m) long cable from the transducers to the electronics.
      • Shall include manufacturer's recommended sensor coupling compound.
      • Shall include stainless steel sensor mounting guiderails with clamps permitting installation and removal of transducers.
      • Shall include a transducer test block to allow the transducers and inter-connecting cables to be functionally checked.


      Additional Information:

      • Item Code: PT400

      View Complete details

      get quote request a call back
      • MANTARAY Portable Area Velocity Flow Meter
      • MANTARAY Portable Area Velocity Flow Meter
      • MANTARAY Portable Area Velocity Flow Meter
      • MANTARAY Portable Area Velocity Flow Meter
      • MANTARAY Portable Area Velocity Flow Meter
      • MANTARAY Portable Area Velocity Flow Meter
      MANTARAY Portable Area Velocity Flow Meter

      MANTARAY Portable Area Velocity Flow Meter

      Rs 4.8 Lakh  / PieceGet Best Price

      Product Brochure

      BrandPulsar / Greyline
      Application MediaWater
      Power Supply100 W Max
      Frequency50/60 Hz
      Voltage100-240 V
      Operating Temperature-20 DegreeC to +60 DegreeC (-5 DegreeF to +140 DegreeF)
      Accuracy- Level: +-0.25% of Range or 1 mm (0.04 in). Velocity: +-2% of reading - Repeatability and Linearity:
      Electronics EnclosureIP67 polycarbonate
      Battery Charger6 A (100 W Max), 100-240 V AC 50/60 Hz input, UL and CE listed
      Electrical Surge ProtectionSensor, 4-20mA outputs, and AC power input
      Logger IntervalsProgrammable 10, 30 sec, 1, 2, 5, 10, 15, 30, 60 min
      Channel TypesRound pipe, Rectangular, trapezoid, egg or custom shapes
      DisplayWhite,backlit matrix-displays flow rate,totalizer,relay states, operating mode and calibration menu
      ProgrammingBuilt-in 5-key calibrator with English, French or Spanish language selection
      BatteryInternal rechargeable NiMH, 12V DC, 10,000 mAh
      Approximate Shipping Weight6.8 kg (15 lb)
      Data LoggerProgrammable 2 million point data capacity, time and date stamped plus formatted flow reports
      Breakout BoxConnections for charger input, external battery input, 2 relays, 4-20mA (0-5V)
      SoftwareGreyline Logger for Windows. Graph and data table presentation, level/velocity to flow conversion, e
      Outputs/Communications4-20mA, 500 ohms or 0-5 V DC (100mA) by menu selection 2 solid-state Relays, 40 V AC/DC max.
      Description:
      • The MantaRay Portable Area-Velocity Flow Meter measures flow in open channels, partially filled and surcharged pipes using an ultrasonic sensor. It's designed for monitoring stormwater, sewage, industrial effluent, irrigation water and natural streams. The MantaRay displays and datalogs flow rate and total flow and connects to samplers, SCADA and telemetry systems.
      • Calibration is simple: enter the pipe diameter or channel dimensions and the MantaRay automatically computes and displays the flow rate and total on its backlit LCD display. Mount the sensor at the bottom of the pipe or channel and hang the IP67 electronics case above the high water level.

      Hydrodynamic Ultrasonic Sensor:
      • The MantaRay uses a submerged ultrasonic sensor to continuously measure flow or reverse flow in open channels, partially filled or surcharged pipes. The sensor is a completely sealed ultrasonic unit with no orifices or ports. It is hydrodynamically shaped and designed to shed deposits and stringers for reliable operation in sewage, stormwater and stream flow applications.
      • The QZ02L sensor mounts inside the pipe or at the bottom of an open channel. No special compounds, tools or hardware are required. A stainless steel mounting bracket is included and a size range of optional pipe bands are available for sensor installation in manholes.

      Features:
      • Measures flow in partially filled pipes and open channels
      • No flume or weir required
      • 4-20mA and Relay outputs for connection to Samplers and SCADA
      • Powered with built-in rechargeable NiMH batteries
      • 2 million point data logger with USB output to Flash drives
      • Backlit LCD display for flow rate, totalizer and menu system

      Other Details:
      • Portable Open Channel Flow Meter: Designed for flow surveys in open channels, partially full sewer pipes and surcharged pipes. MantaRay is ideal for stormwater, sewage, irrigation water and natural streams. 
      • Hydrodynamic Ultrasonic Sensor: The MantaRay uses a submerged ultrasonic sensor to continuously measure both Velocity and Level in the channel. The sensor resists fouling, corrosion and abrasion. View realtime flowrate and total flow on the large backlit LCD display. Connect to samplers or SCADA and telemetry systems with the 4-20mA and relay outputs. Download flow log files to a USB memory stick.


      Additional Information:

      • Item Code: MantaRay

      View Complete details

      get quote request a call back
      • AVFM 5.0 Area Velocity Flow Monitor
      • AVFM 5.0 Area Velocity Flow Monitor
      • AVFM 5.0 Area Velocity Flow Monitor
      AVFM 5.0 Area Velocity Flow Monitor

      AVFM 5.0 Area Velocity Flow Monitor

      Rs 2,500  / PieceGet Best Price

      Product Brochure

      Usage/ApplicationLaboratory
      Display TypeLCD
      BrandPulsar / Greyline
      Electronics EnclosureWatertight and dust tight NEMA4X (IP 66) polycarbonate with clear, shatterproof cover
      Power Input100-240VAC 50-60Hz (see Options), 3.0-6.24 Watts depending on options
      Outputs3 Isolated 4-20mA, 1000 ohm, (Flow, Level and Velocity) or 0-5VDC by menu selection
      Electrical Surge ProtectionSensor, 4-20mA outputs and AC power input
      Operating Temperature-5 deg to 140 degF (-20 deg to 60 degC)
      Programmingbuilt-in 5-key calibrator with English, French or Spanish language selection
      Approximate Shipping Weight10 lbs. (4.5 kg)
      DisplayWhite,backlit matrix displays flow rate, totalizer, relay states,operating mode and calibration menu
      AccuracyLevel +/-0.25% of Range. Velocity +/-2% of Reading. Repeatability and Linearity +/-0.1%
      Channel TypesRound pipe, Rectangular, trapezoid, egg or custom shapes
      Description:
      • Monitor flow through open channels, partially full sewer pipes and surcharged pipes without a flume or weir. Ideal for stormwater, combined effluent, raw sewage, irrigation water and streams. Calibration is simple: enter the pipe diameter or channel shape and the AVFM 5.0 computes the flow volume and displays the flow rate. Measure forward and reverse flow and calibrate to channels of any shape.

      How It Works:
      • The AVFM 5.0 uses a submerged ultrasonic sensor to measure both Velocity and Level in the channel. The sensor is completely sealed with no orifices or ports. It mounts inside a pipe or at the bottom of a channel.

      Features:
      • For Open Channels and Pipes No Flume or Weir Required
      • Ultrasonic - Measures Velocity + Levelto Calculate Flow
      • Works in partially filled and surcharged pipes
      • 3 Isolated 4-20mA Outputs(Flow, Level and Velocity)
      • Isolated 4-20mA/0-5V Output
      • Totalizer and 2 Control Relays
      • Optional Intrinsically Safe Sensor
      • Optional built-in 2-million point Data Logger

      Other Details:
      • Area-Velocity Flow Meter: Monitor flow through open channels, partially full sewer pipes and surcharged pipes without a flume or weir. Ideal for municipal stormwater, combined effluent, raw sewage and irrigation water.
      • Submersible Ultrasonic Sensor: The AVFM 5.0 uses a submerged ultrasonic sensor to continuously measure both Velocity and Level in the channel. The sensor resists fouling, corrosion and abrasion. The flowmeter can be configured with the standard submerged velocity-level sensor, or with submerged velocity plus a separate non-contacting ultrasonic level sensor.
      • View flowrate and total flow on the large backlit LCD display and connect to external devices with three 4-20mA outputs and two control relays.


        Additional Information:

        • Item Code: AVFM-5.0

        View Complete details

        get quote request a call back
        • DFS 5.1 Doppler Flow Switch
        • DFS 5.1 Doppler Flow Switch
        • DFS 5.1 Doppler Flow Switch
        • DFS 5.1 Doppler Flow Switch
        DFS 5.1 Doppler Flow Switch

        DFS 5.1 Doppler Flow Switch

        Price on Request

        Product Brochure

        Control Relay5 A DPDT
        Set PointsON/OFF adjustment from 0.075 m/s to 3 m/s (0.25 ft/s to 10 ft/s)
        Pipe SizeAny pipe ID from 12.7 mm to 4.6 m (0.5 in to 15 ft)
        Electronics Operating Temperature-23 DegreeC to 60 DegreeC (-10 DegreeF to 140 DegreeF)
        Accuracy+-2%, requires solids or bubbles minimum size of 100 microns, minimum concentration 75 ppm.
        Shipping Weight3.6 kg (8 Ibs)
        EnclosureNEMA4X (IP 67) polycarbonate with a clear shatter-proof face
        Power Input100-240 V AC 50/60 Hz (+-10%), 2 W
        Description:Flow Switch With Non-Contacting Sensor:
        • Flow Control from the Outside of Metal or Plastic Pipes
        • 5 A DPDT Control Relay
        • Adjustable ON/OFF Set-Points
        • High or Low Flow Alarm Mode
        • Adjustable Time Delay
        • Relay Status LED
        • Flow Rate LED bar graph


        Additional Information:

        • Item Code: DFS-5.1

        View Complete details

        get quote request a call back
        • Open Channle Flow & Tank Level Meter OCF 6.1
        • Open Channle Flow & Tank Level Meter OCF 6.1
        • Open Channle Flow & Tank Level Meter OCF 6.1
        • Open Channle Flow & Tank Level Meter OCF 6.1
        • Open Channle Flow & Tank Level Meter OCF 6.1
        • Open Channle Flow & Tank Level Meter OCF 6.1
        Open Channle Flow & Tank Level Meter OCF 6.1

        Open Channle Flow & Tank Level Meter OCF 6.1

        Price on Request

        Product Brochure

        BrandPulsar / Greyline
        Application MediaWater
        DisplayDigital
        Accuracy+-0.25% of Range or 2 mm (0.8 in) whichever is greater. Repeatability & Linearity: +-0.1%
        Electronics EnclosureNEMA4X (IP 66) polycarbonate with clear, shatterproof cover
        Frequency50/60 Hz
        Voltage100-240 V
        Power Input100-240 V AC 50/60 Hz, see Options. 10 VA max depending on options
        ProgrammingBuilt-in 5-key calibrator with English, French, or Spanish language selection
        Control Relays2 Relays, form 'C' dry contacts rated 5 amp SPDT; programmable level alarm, pump control, pump alter
        OutputIsolated 4-20mA / 0-5 V, 1000 ohms load maximum
        Electrical Surge ProtectionSensor, 4-20mA and, AC power input
        OCF DisplayWhite, backlit matrix - displays flow rate, totalizer, relay status, operating mode, and calibration
        Approximate Shipping Weight4.5 kg (10 lbs)
        Data LoggerBuilt-in 26 million point data logger with a USB output and Windows software
        Operating Temperature-20 DegreeC to 60 DegreeC (-5 DegreeF to 140 DegreeF)
        The OCF 6.1 is an open channel flow meter that doubles as a tank level meter, making it a perfect solution for both non-contacting flow measurement and level measurement. The non-contacting open channel flow meter is able to continuously monitor, display, totalize, and data log flow through any flume or weir. The ultrasonic sensor supplied with the OCF 6.1 mounts just 203.2 mm (8 in) above the flowing water giving +/- 0.25% accuracy. 

        View Complete details

        get quote request a call back
        • Non Contacting Area Velocity Monitoring
        • Non Contacting Area Velocity Monitoring
        • Non Contacting Area Velocity Monitoring
        • Non Contacting Area Velocity Monitoring
        • Non Contacting Area Velocity Monitoring
        Non Contacting Area Velocity Monitoring

        Non Contacting Area Velocity Monitoring

        Price on Request
        Usage/ApplicationAir Velocity
        Display TypeDigital
        Model Name/NumberNon Contacting Area Velocity Monitoring
        Operating Temperature-20 degree to 50 degree
        Power Supply115 V AC +5% / - 10%, 230 V AC +5% / - 10% 50/60 Hz, 22-28 V DC, 10 W maximum power (typically 6 W)
        BrandPulsar / Greyline
        Weight1 kg (2.2 lbs)
        Programming SecurityVia passcode (user selectable and adjustable)
        Controller Body Dimensions235 mm x 184 mm x 120 mm (9.25 in x 7.24 in x 4.72 in)
        On Board ProgrammingVia Integral Keypad
        IP RatingIP65/NEMA 4X
        Cable Entry Detail10 cable entry knock outs, 1 x M16, 5 x M20 underside, 4 x 18 mm dia (PG11) at rear
        The dBMACH3 and dB3 with double sun shields are specially designed for non-invasive flow measurement. Many flow metering devices require mounting in the bottom of a pipe or channel, which requires a shutdown of the operation for installation to take place. The dBMACH3 and dB3 with double sun shields are the ideal alternative open-channel flow sensors. The dBMACH3 is the first ultrasonic sensor to achieve a zero-effective blanking distance. The dB3 with double sun shields adds extra solar radiation protection to the sensor to ensure that the internal temperature can be utilized, ensuring flow measurement readings are as accurate and reliable as possible.

        • Easy prompt set up 
        • Standard onboard memory gives 1-year log at 10-minute intervals
        • 5 control/alarm relays 
        • Flow totalization and outputs 
        • Universal flow calculation with 32 set points 
        • Penstock control using step time 
        • Modbus and Profibus options 

        View Complete details

        get quote request a call back
        DFM-5.1 Doppler Flow Meters

        DFM-5.1 Doppler Flow Meters

        Rs 2.98 Lakh  / PieceGet Best Price

        Product Brochure

        Accuracy+/- 2% of reading or 0.05 ft/sec (0.015 m/sec). Requires solids or bubbles minimum
        CalibrationBuilt-in 5-key calibrator with English,French or Spanish language selection
        OutputIsolated 4-20 mA (1000 ohm load max.)
        Pipe SizeAny pipe from 1/2'' to 180'' (12.7 mm to 4.5 m) ID
        Enclosure HeaterFor outdoor installation,16 watt thermostatically controlled to -40 deg F (-40 deg C)
        Flow Rate Range+/-0.1 +/-0.03 to 40 ft/sec ( to 12.2 m/sec) in most applications
        Control Relays4 additional (6 total) rated 5 ampere SPDT
        Power Input9-32 V DC
        Data LoggerBuilt-in 2 million point logger with output and Windows software
        Description:
        The Greyline Instruments DFM 5.1 Doppler flow meter is a simple, non-contact meter designed for applications that would defeat regular contacting flow meters. Because the sensor is mounted on the outside of the pipe, it is unaffected by abrasives or harsh chemicals making it ideal for wastewater, slurries, sludge, chemicals, viscous liquids and abrasives. There is no obstruction to flow and no pressure drop. The DFM 5.1 is recommended for full pipes and any fluid that contains solids or bubbles.                                                                                       FEATURES                                                  
        • Flow Rate of ±0.1 to 40ft/sec in most applications
        • Any pipe ID from 1/2 to 180in
        • ±2% of scale accuracy
          • Requires solids or bubbles of at least 100 microns
          • 75ppm concentration
        • ±0.1%, Linearity ±0.5% of full scale repeatability
        • Large, backlit LCD display
        • 12-Digit totalizer
        • Reverse flow measurement
        • Isolated 4-20mA (1000 ohm)
        • 2 programmable control relays (upgradeable to 6)
        • Automatic sensitivity adjustment
        • Built-in 5-key calibrator
        • 2 million point data logger optional
          • USB output to flash memory


        Additional Information:

        • Item Code: DFM-5.1

        View Complete details

        get quote request a call back
        OCF 5.0 Open Channel Flow Monitor

        OCF 5.0 Open Channel Flow Monitor

        Rs 2,500  / PieceGet Best Price

        Product Brochure

        DisplayWhite,backlit matrix displays flow rate,totalizer,relay status,operating mode and calibration menu
        Operating Temperature-5 deg to 140 deg F (-20 deg to 60 deg C)
        Accuracy+/-0.25% of Range or 2 mm (0.08'') whichever is greater, Repeatability and Linearity+/-0.1%
        OutputIsolated 4-20mA/0-5V, 1000 ohm load maximum, programmable offset
        Approximate Shipping Weight10 lbs (4.5 kg)
        ProgrammingBuilt-in 5-key calibrator with English, French or Spanish language selection
        Power Input100-240VAC 50-60Hz (see Options), 2.95-5.6 Watts depending on options
        Electronics EnclosureWatertight and dust tight NEMA4X (IP 66) polycarbonate with clear, shatterproof cover
        Electrical Surge ProtectionSensor, 4-20mA and AC power input
        Description:
        • Continuously monitor, display, totalize and data log flow through any flume or weir. The OCF 5.0 includes a non-contacting ultrasonic sensor that mounts just 8" (203.2 mm) above the flowing water. It is accurate (±0.25%) and reliable. There is no obstruction to flow and no fouling. Use the built-in Keypad/menu system to select your flume or weir from the Menu and to choose measurement units (gallons, liters etc.)
        • The Greyline OCF 5.0 includes built-in 2-million point Data Logger and flow reporting system. Connect a flash memory stick to the flowmeter's USB output to download log files and then view your data in graph and table formats with 'Greyline Logger' software – supplied free with each OCF 5.0. Daily flow reports including minimum, maximum, average and total daily flow can be viewed directly on the backlit OCF 5.0 LCD display. New! Logger Download to USB Flash Drive
        • Use the isolated 4-20mA to transmit flow to remote chart recorders or displays, and the control relays are programmable for level/flow alarm, and flow proportionate pulse (for samplers, chlorinators or remote totalizers). An Intrinsic Safety Barrier is optional for sensor and cable installation in hazardous rated locations. The separate, watertight electronics/display enclosure is mounted at a convenient location within 500 ft (150 m) of the sensor.

        Features:
        • Non-Contacting Ultrasonic Sensor
        • Large, Backlit LCD Display
        • 12-Digit Totalizer
        • Isolated 4-20mA (1000 ohm)
        • 2 Programmable Control Relays
        • Automatic Sensitivity Adjustment
        • Built-in 5-Key Calibrator
        • Optional 2 million point Data Logger with USB output to Flash memory

        Other Details:
        • Non-Contacting Sensor: The OCF 5.0 uses a non-contacting ultrasonic sensor mounted over a flume or weir to measure flow. It is accurate, reliable and verifiable. The separate, watertight electronics/display enclosure can be mounted within 500 ft (150 m) of the sensor. The OCF 5.0 continuously displays, totalizes, transmits and data logs open channel flow.
        • Keypad Operating System: Use the built-in keypad for fast, easy calibration with menu selection of flume or weir and measurement units (e.g. gallons, liters etc.) Calibration values and data logs are password-protected and retained during power interruptions. The OCF 5.0 will display on-screen flow reports with daily total, minimum, maximum and average flow and will transfer data logs to a USB flash drive. PC software is included.


          Additional Information:

          • Item Code: OCF-5

          View Complete details

          get quote request a call back
          Transit Time Flow Meter for Clean Liquid

          Transit Time Flow Meter for Clean Liquid

          Rs 25,000  / PieceGet Best Price
          DisplayWhite, back light matrix
          BrandGreyline
          Totalizer14 digits
          CalibrationBuilt-in 5-key programmer
          OutputIsolated 4-20 mA (1000 ohm)
          Transit Time Flow Meter for Clean Liquid Accurately measure the flow rate of clean, non-aerated liquids like water, chemicals, and oils in full pipes. Ultrasonic transducers mount on the outside of a pipe without shutting down flow. Flow rate is displayed on the large, back light display along with totalizer and signal strength. Use the built-in control relays for flow alarms or flow proportionate pulse. Connect the isolated 4-20 mA output to PLC's or controllers. The TTFM 1.0 works on a wide range of pipe sizes and materials including carbon steel, stainless steel, ductile iron, cast iron, PVC, PVDF, fiberglass, copper, brass, aluminum and pipes with bonded liners including epoxy, rubber and Teflon. The TTFM 1.0 Transit Time Flow meter operates by measuring the “transit time” or “time of flight” for ultrasonic sound pulses transmitted from one transducer to another. Depending on the mounting configuration, the signal may cross the pipe once, twice or four times. To measure flow the transit time is compared between ultrasonic signals traveling upstream and downstream.

          Features:
          • Non-Contacting Clamp-on Ultrasonic Transducers
          • Works on Metal and Plastic Pipes
          • Large Back light Flow Rate Display and Totalizer
          • Isolated 4-20 mA Output
          • Built-in 5-Key Calibrator
          • 2 Programmable Control Relays
          • Optional 20 Million Point Data Logger

          Product Details:
          • pair SE16B ultrasonic transducers - clamp-on for 1/2” to 48” (12 mm to 1200 mm) pipes and rated nonincendive for Class I, Division 2, Groups A, B, C & D locations
          • Sensor cables - pair 25 ft / 7.6 m coaxial with BNC connectors
          • Flow rate range: ± 0.07 to 39 ft/sec (± 0.02 to 12 m/sec)
          • Installation - stainless steel transducer mounting brackets and clamps, alignment bar and silicone coupling compound kit
          • Enclosure - watertight, NEMA4X (IP66) polyester and polycarbonate
          • 2 control relays - 5 amp, SPDT - programmable for flow proportional pulse output, and/or flow alarm
          • Plug-and-play options including data logger and extra control relays
          • Electrical surge protection and RFI filters - AC, sensor, 4-20 mA


          Additional Information:

          • Item Code: TTFM-1

          View Complete details

          get quote request a call back
          Open Channel Flow Monitor

          Open Channel Flow Monitor

          Rs 25,000  / PieceGet Best Price
          MaterialPlastic Body
          Usage/ApplicationAutomotive
          DisplayDigital
          BrandGreyline
          EnclosureWatertight NEMA4X (IP 67) polycarbonate
          Sensor Cable20ft (6 m) shielded coaxial pair
          Power Input120 VAC 50/60 Hz
          Time DelayAdjustable, 0-60 seconds
          Features:
          • Sensor: Strap-on, single head ultrasonic
          • Installation: Sensor compound kit and stainless steel pipe clamp
          • 1 relay: 5 amp DPDT
          • Set point: ON/OFF adjustment 0.25 to 10 ft/sec (0.076 to 3 m/sec)
          • Failsafe mode: Switch selectable
          • Indication: Relays and signal strength LED's
          • Sensitivity: Adjustable
          • Electrical surge protection
          • 1 manual: Installation and Operation

          Open Channel Flow Monitor Specifications:Scope: 
          • This Specification Covers An Ultrasonic, Echo-Ranging Type Open Channel Flow Meter As Manufactured By Grey line Instruments, Massena, New York / Long Sault, Ontario. This Instrument Shall Provide For Indicating, Transmitting, Totalizing And Data Logging Of The Flow Rate Through A Flume, Weir, Or Other Primary Measuring Device.

          General:
          • Flow Monitor To Consist Of An Non-Contacting Ultrasonic Sensor, Connecting Cable, And A Remote Enclosure With Indicating, Transmitting, Controlling And Data Logging Electronics
          • Measurement Accuracy Shall Be ±0.25% And Shall Be Automatically Temperature Compensated
          • Sensor Cable Length Shall Be As Required By Installation, Not To Exceed 500 Ft (152 M)
          • System Shall Have No Moving Parts And Shall Not Contact Flowing Water

          Sensing Element:
          • Sensor Shall Withstand Accidental Submersion To 20 Psi
          • Sensor Minimum Range Shall Be 8" (203.2 Mm) And Maximum Range Shall Be 15 Ft (4.57 M)
          • Sensor Shall Be Constructed Of Pvc
          • Sensor Operating Temperature Shall Be From -40°F To 150°F (-40°C To 65°C)
          • Sensor Shall Include Integral Temperature Sensor. Temperature Sensors Requiring Separate Mounting And Wire Runs Shall Not Be Accepted


              Additional Information:

              • Item Code: OCF-4

              View Complete details

              get quote request a call back
              Doppler Flow Meter

              Doppler Flow Meter

              Rs 25,000  / PieceGet Best Price
              MaterialPlastic Body
              Application MediaWater
              BrandGreyline
              Frequency50/60 Hz
              Voltage220 V
              OutputIsolated 4-20 Ma (1000 Ohm)
              SensorStrap-On,Single Head Ultrasonic For 1/2" to 180" (12.5 Mm to 4.5 M) Id Pipes
              Sensor Cable20 Ft / 6 M Shielded Coaxial Pair
              Power Input100-130 VAC 50/60 Hz
              Features:
              • Installation: Sensor Compound Kit: Pc3 Stainless Steel Sensor Mounting Clamp
              • Enclosure: Watertight Nema4X (Ip66) Polycarbonate
              • Displays: Flow Rate: Large 4-Digit Lcd: Totalizer/Menu/Status: 16-Digit Alphanumeric
              • Calibration: Built-In 3-Key Programmer
              • Sensitivity: Keypad Adjustable
              • Sensitivity: Keypad Adjustable
              • 3 Control Relays: 5 Amp Spdt: Programmable For Flow Proportional Pulse Output, And/Or Flow Alarm
              • Back flow Rejection: External, Voltage-Free Relay Input
              • Electrical Surge Protection And Rfi Filters: Ac Line, Sensor, 4-20Ma
              • 1 Manual: Installation And Operation

              Doppler Flow Meter SpecificationsScope: 
              • This Specification Covers A Non-Intrusive, Ultrasonic Doppler-Type Flow Meter As Manufactured By Grey line Instruments Inc., Massena, New York / Long Sault, Ontario. The Instrument Shall Provide For Velocity Or Volumetric Indicating And Transmitting Of The Flow Rate In A Full Pipe.

              Performance Specifications:
              • The Flow Meter Shall Operate With A Single-Head Flow Sensor Mounted Externally On Any Contiguous Pipe Material That Conducts Sound Including: Carbon Steel, Stainless Steel, Ductile Iron, Copper, Frp, Pvc, Abs, Or Cement Lined Pipe From 1/2" To 180" (12.5 Mm To 4.5 M) Id
              • Measure And Indicate Flow Rates Between 0.2 To 40 Ft/Sec (0.06 To 12.2 M/Sec) With Accuracy Of ±2% Of Full Scale On Liquids With Entrained Particles Or Gases Of 100 Microns Or Larger And Minimum Concentrations Of 75 Ppm

              Transducer (Flow Sensor):
              • The Flow Sensor Shall Be Single-Head, Ultrasonic In A Stainless Steel Housing. It Shall Be Installed On The Outside Of A Pipe Without Interrupting Flow. The Sensor Shall Be Capable Of Continuous Operation At Temperatures From -40°F To 200°F (-40°C To 93°C), And To Withstand Accidental Submersion Pressures To 10 Psi. Manufacturers Recommended Coupling Compound And Stainless Steel Mounting Clamp Shall Be Included
              • Shall Include 20 Ft (6M) Sensor Cable, Shielded Coaxial Pair
              • Shall Be Capable Of Extending Sensor Cable Up To 500 Ft (152M) Without Requirement For Operator Adjustment
              • Shall Be Transformer Isolated And Designed To Meet Intrinsic Safe Requirements. Shall Be Designed For Maximum Rfi Rejection, And Include Automatic High Voltage Bleeds For Nearby Lightning Strikes.


              Additional Information:

              • Item Code: DFM-40

              View Complete details

              get quote request a call back
              Blue-Point 1/2" Driver Impact Socket Set

              Blue-Point 1/2" Driver Impact Socket Set

              Rs 3,500  / PieceGet Best Price
              BrandBlue-Point
              Model Name/NumberBLPATSIMM 1215
              Usage/ApplicationAutomobile Industry
              Socket TypeImpact Socket
              Drive Size1/2 Inch
              Blue-Point 1/2" Driver Impact Socket Set contains 14 pcs. of Impact socket 6-point and 1 pcs of Impact Extension Bar.

              View Complete details

              get quote request a call back
              KTS 560 Bosch

              KTS 560 Bosch

              Rs 25,000  / PieceGet Best Price
              Voltage8 VDC - 28 VDC
              BrandBosch
              Accuracy+-0.75 % of measured value,plus +-0.25 % of measuring range
              ConnectivityUSB 2.0
              Model Name/NumberKTS 560
              Product ConditionNew
              The sturdy new KTS equipment, KTS 560 and KTS 590, are based on the Bosch diagnostic application ESI[tronic] 2.0. Not only do they support all of today's relevant diagnosticprotocols, but also future protocols based on Ethernet.
              Apart from vehicle diagnosis, voltage, resistance, and current can be measured easily and efficiently.
              The KTS 590 is equipped with a two-channel oscilloscope, that provides visual indication and analyses of voltage and current over time.
              KTS 590 and KTS 560 can be used to measure vehicle signals from sensors and actuators.
              The device also has a powerful in-built Bluetooth@ hardware that enables wirelessconnection to any Windows-based PC.

              KTS 590 ECU diagnosis and measurement technology(1-chan nel multimeter)

              View Complete details

              get quote request a call back
              • PSL 5.0 Hybrid Pump Station Level Controller
              • PSL 5.0 Hybrid Pump Station Level Controller
              • PSL 5.0 Hybrid Pump Station Level Controller
              • PSL 5.0 Hybrid Pump Station Level Controller
              PSL 5.0 Hybrid Pump Station Level Controller

              PSL 5.0 Hybrid Pump Station Level Controller

              Price on Request

              Product Brochure

              Voltage240V AC
              Operation TypeFully Automatic
              DisplayWhite, backlit matrix - displays calibration menu, relay status, runtime reports and sensor status
              Phase1-Phase
              Operating Temperature-20 DegreeC to 60 DegreeC (-5 DegreeF to 140 DegreeF )
              Accuracy+-0.25% of range or 2 mm (0.08 in), whichever is greater
              CalibrationLevel or Range mode in selectable units
              Surge ProtectionAC power, 4-20mA and ultrasonic sensor
              ProgrammingBuilt-in, 5-button keypad, password-protected
              Power Input100-240 V AC 50/60 Hz, 2.4-5.6 W depending on options
              OutputsIsolated 4-20mA (1000 ohm)
              Control Relays6 form 'C' dry contact relays rated 5 A SPDT; programmable level alarm and/or pump control modes
              Electronics EnclosureNEMA4X (IP 66) polycarbonate with clear, shatterproof cover
              DESCRIPTION                                           The PSL 5.0 Pump and Lift Station Level Controller is an ultrasonic level sensor that mounts above the liquid surface for accurate and reliable non-contacting level measurement. The PSL 5.0 is ideal for sewage pump stations, lift stations, wet wells, and tank level measurements. The unit includes six independently programmable control relays for pump or valve control, level alarms, dialers, temperature alarm, and echo loss alarms. The easy-to-use simple menu system and built-in keypad can be used to program application parameters such as measurement ranges, relay set points, and pump alternation sequences. The PSL 5.0 also includes the ability to connect a submersible pressure sensor, or any other 4-20mA level sensor, for fail-safe hybrid sensing. Perfect for wastewater control, sump control, wet well level monitoring, and industrial applications where backup measurement sensors are required.                                                                       FEATURES                                                    
              • Low Cost
              • Isolated 4-20mA Output (1000 ohm)
              • Large LCD Display
              • Programmable Signal Relay
              • Non-Contacting Ultrasonic Sensor or Optional Pressure Sensor
              • Built-in 2-Key Calibrator
              • Watertight, Dust-tight Enclosure
                      


              Additional Information:

              • Item Code: PSL-5.0

              View Complete details

              get quote request a call back
              • Fuel Oil Level Transmitter
              • Fuel Oil Level Transmitter
              • Fuel Oil Level Transmitter
              Fuel Oil Level Transmitter

              Fuel Oil Level Transmitter

              Rs 2,500  / PieceGet Best Price
              TypeDigital
              MaterialSS
              Accuracy+/- 0.1%
              Power Supply24 V DC
              Range0-70380 mmH2O
              Country of OriginMade in India
              With our rich industry experience and knowledge, we are engaged in trading and supplying high quality Fuel Oil Level Transmitter. Our vendors professional design and manufacture these transmitters utilizing exceptional quality raw material and modern technology. In addition, we offer this atta chakki in various specifications and can be customized according to the particular requirements of the clients.

              Features:
              • Superior performance
              • Longer service life
              • Durable finish
              • User friendly

              Applications:
              • Diesel fuels
              • Hydraulic oils
              • Vegetable oils
              • Chemical holding tanks
              • MEK and other solvents
              • Many other, non-conductive liquids

              View Complete details

              get quote request a call back
              • TDR Level Transmitter
              • TDR Level Transmitter
              • TDR Level Transmitter
              TDR Level Transmitter

              TDR Level Transmitter

              Rs 2,500  / PieceGet Best Price
              TypeDigital
              MaterialStainless Steel
              Measuring Range30 m
              Output Signal4-20 mA
              Accuracy+/-3 mm
              Power Supply24 V DC/220 V AC
              Country of OriginMade in India
              We are an unparalleled name, engaged in trading and supplying a premium quality TDR Level Transmitter that is widely used in various industries like food processing, chemical, pharmaceutical, and many more. Offered transmitter is designed and manufactured using finer quality raw material, procured from the authentic vendors of the market. Also, we offer this transmitter to our precious client’s at most competitive price range.

              Features:
              • Precise size
              • High durability
              • Fine finish
              • Easy installation

              View Complete details

              get quote request a call back
              • LIT25 Level Indicating Transmitter
              • LIT25 Level Indicating Transmitter
              • LIT25 Level Indicating Transmitter
              LIT25 Level Indicating Transmitter

              LIT25 Level Indicating Transmitter

              Price on Request

              Product Brochure

              TypeDigital
              Accuracy+-0.25% of range or 2 mm (0.08 in); whichever is greater
              OutputIsolated 4-20mA, 1000 ohm load maximum
              ProgrammingBuilt-in 2- button keypad with menu selection. Calibration parameters are permanent when stored, eve
              Temperature compensationTemperature probe inside the level sensor for high accuracy in changing temperatures
              Approximate Shipping Weight2.7 kg (6 lbs)
              Signal Relay1 Relay, rated 120-240 V AC or 24 V DC, 1 A, programmable for level alarm, echo loss alarm
              Electronics EnclosureNEMA4X (IP 66) polycarbonate with clear, shatterproof cover
              Electrical Surge ProtectionSensor, 4-20mA and AC power input
              Operating Temperature-25 DegreeC to 60 DegreeC (-13 DegreeF to 140 DegreeF )
              DisplayLarge 19 mm (0.75 in) high, 4-digit LCD
              CalibrationSelectable Level or Range mode. Enter min. and max. distance in inches or cm
              Power Input100-130 V AC 50/60 Hz, 5 watts maximum
              DESCRIPTION                                                  The LIT25 is a level indication sensor that displays, controls, and transmits level. The non-contacting level sensor mounts at the top of a tank and the compact, watertight display enclosure is mounted at a convenient location nearby. Operators can calibrate the LIT25 with its 2-button keypad, without climbing to the top of the tank, enabling organizations to gain better stock and inventory control and tank level measurement that complies with health and safety regulations. 

              Use the built-in relay for level control or alarm, the large 4-digit display for local indication, and the isolated 4-20mA output to transmit level to a PLC. The standard ultrasonic level sensor measures liquid levels up to 9.8 m (32 ft) and includes automatic temperature compensation allowing for that all-important, reliable, level measurement even when conditions within the application are changing. The optional all-Teflon sensor enables the LIT25 to provide level measurement for chemical applications and all ultrasonic sensors are available with optional intrinsic safety approvals for installation in hazardous rated locations.                                                                  FEATURES                                                     

              • Low Cost
              • Isolated 4-20mA Output (1000 ohm)
              • Large LCD Display
              • Programmable Signal Relay
              • Non-Contacting Ultrasonic Sensor or Optional Pressure Sensor
              • Built-in 2-Key Calibrator
              • Watertight, Dust-tight Enclosure

               



              Additional Information:

              • Item Code: LIT25

              View Complete details

              get quote request a call back
              Stingray 2.0 Portable Level-Velocity Logger

              Stingray 2.0 Portable Level-Velocity Logger

              Rs 25,000  / PieceGet Best Price

              Product Brochure

              Number of Channels4
              AccuracyLevel +/-0.25% of Range, Velocity +/-2% of Reading
              DisplayLCD displays Level, Velocity, Water Temperature, Battery and Memory capacity
              Instrument Set upvia Greyline Logger software for Windows Logging Time Interval, Site Name
              Power4 Alkaline 'D' cell batteries
              USB Cable3 1 shielded ft ( m)
              Approximate Shipping Weight10 lbs. (4.5 kg)
              Operating Temperature Range-4 deg to 140 deg F (-20 deg to 60 deg C)
              Output CommunicationsUSB
              Data Logger Capacity130,000 data points
              Electronics EnclosureWatertight, airtight, dust proof ( 67) polycarbonate IP
              Description:
              • Stingray 2.0 measures evel and elocity in open channels or pipes. No calibration is required. The sensor l v is a completely sealed ultrasonic unit with no orifices or ports. It mounts inside the pipe or at the bottom of a channel. The watertight electronics enclosure is hung in the manhole or at a convenient location. Sensor, mounting bracket, batteries, software and cables are included with each Stingray.
              • Compact and Portable: Stingray 2.0 is a compact, battery-powered logger with an ultrasonic sensor. It data logs level, velocity and water temperature readings for flow monitoring through open channels, partially full sewer pipes and surcharged pipes. Use it for flow surveys, I & I studies, stormwater, irrigation water and sewage.
              • Hydrodynamic Ultrasonic Sensor: Stingray 2.0 uses a submerged ultrasonic sensor to continuously measure both velocity and level in the channel. The sensor is a completely sealed ultrasonic unit with no orifices or ports. It is hydrodynamically shaped and designed to shed deposits and stringers for reliable operation in sewage, stormwater and stream flow applications. The QZ02L sensor mounts inside the pipe or at the bottom of an open channel. No special compounds, tools or hardware are required. A stainless steel mounting bracket is included.
              • Powered by Standard Alkaline Batteries: With 4 standard Alkaline D-cell batteries the Stingray 2.0 will operate up to 4 years! These inexpensive Alkaline batteries are available in stores everywhere and with an extremely low self discharge rate they will reliably power the energy-efficient Stingray 2.0 for the duration of your flow study.
              • Stingray 2.0 stores 130,000 data points including level, velocity and water temperature. Between readings it powers down to conserve energy.
              • Stingray 2.0 Confidence Display: You can check operation with the built-in LCD bar graph display. It scrolls through level, velocity and temperature readings, plus remaining battery and logger storage capacity. The display turns off automatically after 60 seconds to conserve battery power.

              Features:
              • Logs Level and Velocity
              • for Flow Studies
              • Includes powerful
              • Windows software for
              • Flow analysis and reporting



                Additional Information:

                • Item Code: Stingray2.0

                View Complete details

                get quote request a call back
                Tuning Fork Level Switch

                Tuning Fork Level Switch

                Rs 2.5 Lakh  / PieceGet Best Price
                Working PressureLess than 2 MPA
                Density of MediumMin.05 g/cm3
                Wetted MaterialSS 304,SS 316 L,Coated with PTFE
                Electrical ConnectionM 20 x 1.5
                Connection1" NPT (M)
                We are offering our valuable clients a wide range of Tuning Fork Level Switch. Manufactured utilizing finest quality raw material and is precisely designed under the supervision of adroit professionals, we resourced this level switch from the authentic vendors of the industry. Our clients can avail this level switch in various specifications and can be customized as per their specific requirements at market leading price range.

                Features:
                • Complete electrical design circuit, without maintenance after operation
                • without effect of foam powder
                • special tuning fork design and its inherent vibration characteristic which ensure the function of automatic elimination and maximally prevent material hanging.

                Applications:
                • Liquids, solids, particles and power with good fluidity in various fields

                Working Principle:
                • The electric circuit signal energies the crystal in the fork which makes the probe of the tuning fork vibrate at a certain rate. When the probe is completely whelmed by the material measured, the vibration frequency of the fork will be changed, then the electric of the meter can automatically detect the difference and transfer it into switch will be output by the relay for on-spot alarming and remote control; when the material departs from the probe, the meter restores to the normal working condition to detect the changes of material level. 

                Product Details:
                ModelSD-YCO 1 SA-LM-200
                SD-YC 71
                (Explosion proof type)
                Power Supply24 VAC/DC (Standard)
                220 VAC, 110 VAC(Optional)
                Contact Capacity220 VAC 5A, DPDT
                Medium Temperature-10 °C~80°C (high temperature type:max 150° C)

                View Complete details

                get quote request a call back
                Blue-Point Tools Trolley

                Blue-Point Tools Trolley

                Rs 14,500  / PieceGet Best Price
                BrandBlue-Point
                MaterialMild Steel
                ColorBlue
                Number Of Drawers5
                Load Capacity45 Kg
                Weight65 Kg
                • High grade steel plate with PE Powder painting for better flowingproperty to avoid peel• Fully-openable drawers can withstand up to 45 kg weight• Bigger sized with greater capacity at 508 kg• Tubular lock-stronger over molded key lock• Ribs added for enhanced strength to prevent cabinet deformation

                View Complete details

                get quote request a call back
                Pump Station Level Controller

                Pump Station Level Controller

                Rs 25,000  / PieceGet Best Price
                Sensor TechnologyUltrasonic Sensors
                Voltage12V DC
                Operation TypeManual
                BrandGreyline
                Mounting TypeWall
                Phase1-Phase
                Sensor Cable25ft / 7.6m coaxial
                DisplaysLevel large 4-digit LCD; Menu/Reports/Status 16-digit alphanumeric
                SensorPZ 34, PVC, 32 ft / 10 m range
                Power Input100-130 VAC 50/60 Hz, 8 watts maximum
                Our immense domain expertise and market knowledge assist us to trade and supply the finest quality Pump Station Level Controller. Our vendors’ experts design and manufacture this level controller utilizing higher quality raw material at par with industry standards. The manufacturing process of this level controller is vigilantly examined at each step to ensure its dependability. Also, offered level controller is available in various specifications to our precious clients as per their precise requirement.

                Features:
                • Temperature compensation: Automatic
                • Enclosure: Watertight, dust tight NEMA 4 X (IP 66) polycarbonate
                • Programming: Built-in 3 button keypad, Password protected and "PSL Remote" Windows software
                • Calibration: Level or Range mode in selectable units
                • 6 relays: 5 ampere SPDT, programmable alarm and/or pump control modes, pump alternation/sequencing, failsafe/echo-loss, sensor temperature alarm
                • Outputs: Isolated 4-20 mA (1000 ohm), RS232
                • Report logger: Pump Run Time report
                • Electrical surge protection: Sensor, AC power, 4-20 mA and RS 232 outputs
                • 1 PC software: "PSL Remote" for Windows™ - calibrate and save as disk file, real-time PSL monitoring by RS 232 or modem connection
                • 1 Manual: Installation and Operation

                Pump Station Level Controller Specifications:Scope:
                • This specification covers a non-contacting ultrasonic Pump Station Level Controller as manufactured by Grey line Instruments, Massena New York / Long Sault, Ontario. This instrument shall provide for indicating, transmitting of wet well or tank level, and control of up to six pumps or alarms.

                General:
                • Pump Station Level Controller to consist of an non-contacting ultrasonic sensor, connecting cable, and a remote enclosure with indicating, transmitting and controlling electronics
                • Measurement accuracy shall be ±0.25% of Range or 2 mm (0.08"), whichever is greater, and shall be automatically temperature compensated
                • Sensor cable length shall be as required by installation, not to exceed 500' (152 m)
                • System shall have no moving parts and shall not contact the material being measured
                • Shall include a built-in keypad and simple menu system for calibration, and Windows™ software for calibration and monitoring by modems or direct RS232 connection

                Sensing Element:
                • Sensor shall be constructed of PVC
                • The sensor shall have a minimum dead band or blanking of 16" (407 mm) and a maximum range of 32 ft. (10 m), and have an operating frequency of 46 kHz with an ultrasonic beam angle of 8 Degrees
                • Sensor shall withstand accidental submersion to 20 psi
                • Sensor operating temperature shall be from -40°F to 150°F (-40°C to 65°C)
                • Sensor shall include integral temperature sensor. Temperature sensors requiring separate mounting and wire runs shall not be accepted

                Sensor Connecting Cable:
                • Provide RG 62 AU coaxial cable 25' (7.6 m) continuous length, with waterproof, potted bond to the Sensor head
                • Extended sensor cable shall be RG 62 AU coaxial to a maximum of 500' (152 m). Cable shall be spliced with screw terminal connections in manufacturer's recommended steel NEMA 4 Junction Box
                • Level and temperature signals shall be conducted on one single coaxial cable. Separate or multiple-conductor cables shall not be accepted
                • Sensor cable shall be installed in grounded metal conduit


                Additional Information:

                • Item Code: PSL

                View Complete details

                get quote request a call back