Level Indicating Transmitter

Level Indicating Transmitter
 
Ask For Price
Product Price:  Get Latest Price

Product Details:
Accuracy+/-0.25% of Range or 2 mm (0.08''), whichever is greater
OutputIsolated 4-20mA, 1000 ohm load maximum
Electronics EnclosureWatertight, dust tight NEMA4X (IP 66) polycarbonate with clear, shatterproof cover
DisplayLarge (3/4 in, 19 mm high) 4 digit LCD
CalibrationSelectable Level or Range mode. Enter min. and max. distance in inches or cm
Power Input100-130VAC 50/60Hz, 5 watts maximum
Electrical Surge ProtectionSensor, 4-20mA and AC power input
Operating Temperature-13 to 140 deg F (-25 to 60 deg C) (electronics)
Approximate Shipping Weight6 lbs. (2.7 kg)

Description:
  • This new Greyline Transmitter displays, controls and transmits level. Mount the non-contacting ultrasonic sensor at the top of your tank and the compact, watertight electronics/display enclosure at a convenient location nearby. Operators can calibrate the LIT25 with its 2-button Keypad, without climbing the tank. Use the built-in relay for level control or alarm, the large 4-digit display for local indication, and the isolated 4-20mA output to to transmit level to a PLC.
  • The standard ultrasonic Sensor measures liquid levels up to 32 ft. (10 m), and includes automatic temperature compensation. Choose the optional all-Teflon sensor for chemical compatibility, or one rated to 50 ft (15.6 m) range. All ultrasonic sensors are available with optional intrinsic safety for installation in hazardous rated locations. The LIT25 can also be ordered with gauge-type pressure sensors for special applications.

Features:
  • Simple Calibration with 2-button keypad
  • Large 4-digit LCD display
  • Non-Contacting, no maintenance sensor
  • Isolated 4-20mA output (1000 ohm)
  • Relay for alarm or control
  • Automatic temperature compensation
  • Watertight, dust tight enclosure
  • Low Cost – High accuracy (±0.25%)

Other Details:
  • Transmits: The LIT25 Level Indicating Transmitter features a 4-20mA output rated up to 1000 ohms. This output is isolated and ready for direct connection to your PLC or Controller.
  • Displays: Mount the watertight display enclosure at a convenient location where the large, 4-digit LCD Display is visible to Operators. Use the built-in Keypad for calibration without climbing the Tank.
  • Controls: Use the LIT25 signal Relay output to control pumps and alarms. Calibrate for level, echo loss or temperature alarm.


Additional Information:
  • Item Code: LIT25
Yes! I am Interested
View PDF
Get CALLBACK

PDFM 5.1 Portable Doppler Flow Meter

PDFM 5.1 Portable Doppler Flow Meter
 
Ask For Price
Product Price:  Get Latest Price

Product Details:
DisplayWhite, backlit matrix - displays flow rate, totalizer, operating mode and calibration menu
Flow Rate Range+/- 0.1 to 40 ft/sec (+/- 0.03 to 12.2 m/sec) in most applications
Pipe SizeUltrasonic Sensor mounts on any pipe from 1/2'' to 180'' ID (12.5 mm to 4.5 m)
Power InputBuilt-in NiMH battery for up to 18 hours continuous operation External charger with 100-240VAC
Outputs4-20mA (500 ohm) when AC powered USB for Data Log transfer by direct PC connection
Electronics Operating Temperature-10 deg to 140 deg F (-23 deg to 60 deg C)
Electronics EnclosurePortable, ABS enclosure
Carry CaseRated IP67 with protective molded foam insert
Language SelectionEnglish, French, Spanish
SensitivityAdjustable cut-off, Damping adjustable

Description:
  • It's ideal for flow troubleshooting, balancing and checking performance of permanent flow meters. The new PDFM 5.1 is fast and easy to operate – you can mount the sensor on the outside of a pipe in less than a minute. Use the built-in keypad and calibration menu to set up the flowmeter for your application. The PDFM 5.1 works on any liquid containing bubbles or solids and is recommended for "difficult liquids" like wastewater, slurries, sludge, chemicals, viscous liquids and abrasives. Measures flow through most metal and plastic pipes including PVC, ductile iron, carbon steel and stainless steel.
  • The Greyline PDFM 5.1 is AC/DC powered with built-in NiMH batteries and external charger. With its 4-20mA output you can use the PDFM 5.1 as a spare transmitter in critical applications. For flow studies and troubleshooting use the built-in 300,000 point Data Logger. Retrieve data logs with 'Greyline Logger' software – included free with each PDFM 5.1. Connect the USB output directly to your PC or Laptop to download data logger files.
  • The PDFM 5.1 includes a non-intrusive Doppler ultrasonic sensor for pipes from 1/2" to 180" (12.5 mm to 4.5 m) diameter, a stainless steel sensor mounting bracket and clamps, coupling compound and AC charger with a rugged IP67 carry case. It operates up to 18 hours from internal batteries and recharges overnight.

Features:
  • Clamp-on Ultrasonic Transducer
  • Handheld Meter with large backlit LCD Display and Totalizer
  • Internal Battery and/or AC Powered
  • Built-in 5-Key Calibrator
  • 300,000 point Data Logger
  • USB Output and Windows software
  • 4-20mA Output
  • Rugged, watertight Carry Case

Portable Doppler Flow Meter Specifications:
  • Scope: This specification covers a portable, ultrasonic Doppler-type flow meter as manufactured by Greyline Instruments, Largo, Florida / Long Sault, Ontario. This instrument shall provide for non-intrusive flow measurement, indication, totalizing, transmitting and data logging of the flow rate in a full pipe.

General:
  • Each portable Doppler flow meter shall have the following design features and engineering specifications:

Performance Specifications:
  • Measure forward and reverse flow ± 0.1 to 40 ft/sec (± 0.03 to 12.2 m/sec).
  • Have an accuracy of ±2% of full scale on most wastewater applications. Have linearity of ±0.5% and repeatability of ±0.25%.
  • Operate on liquids with entrained particles or gases of 100 microns or larger and minimum concentrations of 75 ppm.
  • Operate from the outside of common pipe materials including: carbon steel, stainless steel, ductile iron, copper, PVC, FRP, ABS and other selected engineering materials.
  • Operate on AC/DC power.

Transducer:
  • Have a single-head, clamp-on transducer with twin piezo-electric ceramic transmit and receive crystals encapsulated in epoxy resin and a stainless steel housing.
  • The transducer shall be solid state and transformer isolated, and operate at 640KHz.
  • The transducer shall be waterproof and operate at temperatures from -40°F to 300°F (-40°C to 150°C), and withstand accidental submersion to 10 psi.
  • The transducer shall be designed to install on pipes with inside diameter ranging from 1/2" to 180" (12.5 mm to 4.5 m).
  • Have a 12 ft (3.6 m) long flexible, shielded coaxial pair cable extending from the transducer to the electronics.
  • Shall include Manufacturer's recommended sensor coupling compound and adjustable stainless steel sensor mounting clamp.


Additional Information:
  • Item Code: PDFM-5.1
Yes! I am Interested
View PDF
Get CALLBACK

MantaRay Portable Area Velocity Flow Meter

MantaRay Portable Area Velocity Flow Meter
 
Ask For Price
Product Price:  Get Latest Price

Product Details:
Operating Temperature-5 deg to 140 deg F (-20 deg to 60 degC)
AccuracyLevel+/-0.25% of Range or 1 mm (0.04''). Velocity+/-2% of Reading Repeatability and Linearity+/-0.1%
Channel TypesRound pipe, Rectangular, trapezoid, egg or custom shapes
Electronics EnclosureWatertight, airtight, dust proof (IP 67) polycarbonate
DisplayWhite,backlit matrix-displays flow rate,totalizer,relay states, operating mode and calibration menu
ProgrammingBuilt-in 5-key calibrator with English, French or Spanish language selection
BatteryInternal rechargeable NiMH, 12VDC, 10,000 mAh
Battery Charger6A (100W Max), 100-240VAC 50/60Hz input, UL and CE listed
Breakout BoxConnections for charger input, external battery input, 2 relays, 4-20mA (0-5V)
Logger IntervalsProgrammable 10, 30 sec, 1, 2, 5, 10, 15, 30, 60 min
Approximate Shipping Weight15 lbs. (6.8 kg)

Description:
  • The MantaRay Portable Area-Velocity Flow Meter measures flow in open channels, partially filled and surcharged pipes using an ultrasonic sensor. It's designed for monitoring stormwater, sewage, industrial effluent, irrigation water and natural streams. The MantaRay displays and datalogs flow rate and total flow and connects to samplers, SCADA and telemetry systems.
  • Calibration is simple: enter the pipe diameter or channel dimensions and the MantaRay automatically computes and displays the flow rate and total on its backlit LCD display. Mount the sensor at the bottom of the pipe or channel and hang the IP67 electronics case above the high water level.

Hydrodynamic Ultrasonic Sensor:
  • The MantaRay uses a submerged ultrasonic sensor to continuously measure flow or reverse flow in open channels, partially filled or surcharged pipes. The sensor is a completely sealed ultrasonic unit with no orifices or ports. It is hydrodynamically shaped and designed to shed deposits and stringers for reliable operation in sewage, stormwater and stream flow applications.
  • The QZ02L sensor mounts inside the pipe or at the bottom of an open channel. No special compounds, tools or hardware are required. A stainless steel mounting bracket is included and a size range of optional pipe bands are available for sensor installation in manholes.

Features:
  • Measures flow in partially filled pipes and open channels
  • No flume or weir required
  • 4-20mA and Relay outputs for connection to Samplers and SCADA
  • Powered with built-in rechargeable NiMH batteries
  • 2 million point data logger with USB output to Flash drives
  • Backlit LCD display for flow rate, totalizer and menu system

Other Details:
  • Portable Open Channel Flow Meter: Designed for flow surveys in open channels, partially full sewer pipes and surcharged pipes. MantaRay is ideal for stormwater, sewage, irrigation water and natural streams. 
  • Hydrodynamic Ultrasonic Sensor: The MantaRay uses a submerged ultrasonic sensor to continuously measure both Velocity and Level in the channel. The sensor resists fouling, corrosion and abrasion. View realtime flowrate and total flow on the large backlit LCD display. Connect to samplers or SCADA and telemetry systems with the 4-20mA and relay outputs. Download flow log files to a USB memory stick.

Additional Information:
  • Item Code: MantaRay
Yes! I am Interested
View PDF
Get CALLBACK

Stingray 2.0 Portable Level-Velocity Logger

Stingray 2.0 Portable Level-Velocity Logger
 
Ask For Price
Product Price:  Get Latest Price

Product Details:
DisplayLCD displays Level, Velocity, Water Temperature, Battery and Memory capacity
AccuracyLevel +/-0.25% of Range, Velocity +/-2% of Reading
Electronics EnclosureWatertight, airtight, dust proof ( 67) polycarbonate IP
Operating Temperature Range-4 deg to 140 deg F (-20 deg to 60 deg C)
Instrument Set upvia Greyline Logger software for Windows Logging Time Interval, Site Name
Data Logger Capacity130,000 data points
Power4 Alkaline 'D' cell batteries
Output CommunicationsUSB
USB Cable3 1 shielded ft ( m)
Approximate Shipping Weight10 lbs. (4.5 kg)

Description:
  • Stingray 2.0 measures evel and elocity in open channels or pipes. No calibration is required. The sensor l v is a completely sealed ultrasonic unit with no orifices or ports. It mounts inside the pipe or at the bottom of a channel. The watertight electronics enclosure is hung in the manhole or at a convenient location. Sensor, mounting bracket, batteries, software and cables are included with each Stingray.
  • Compact and Portable: Stingray 2.0 is a compact, battery-powered logger with an ultrasonic sensor. It data logs level, velocity and water temperature readings for flow monitoring through open channels, partially full sewer pipes and surcharged pipes. Use it for flow surveys, I & I studies, stormwater, irrigation water and sewage.
  • Hydrodynamic Ultrasonic Sensor: Stingray 2.0 uses a submerged ultrasonic sensor to continuously measure both velocity and level in the channel. The sensor is a completely sealed ultrasonic unit with no orifices or ports. It is hydrodynamically shaped and designed to shed deposits and stringers for reliable operation in sewage, stormwater and stream flow applications. The QZ02L sensor mounts inside the pipe or at the bottom of an open channel. No special compounds, tools or hardware are required. A stainless steel mounting bracket is included.
  • Powered by Standard Alkaline Batteries: With 4 standard Alkaline D-cell batteries the Stingray 2.0 will operate up to 4 years! These inexpensive Alkaline batteries are available in stores everywhere and with an extremely low self discharge rate they will reliably power the energy-efficient Stingray 2.0 for the duration of your flow study.
  • Stingray 2.0 stores 130,000 data points including level, velocity and water temperature. Between readings it powers down to conserve energy.
  • Stingray 2.0 Confidence Display: You can check operation with the built-in LCD bar graph display. It scrolls through level, velocity and temperature readings, plus remaining battery and logger storage capacity. The display turns off automatically after 60 seconds to conserve battery power.

Features:
  • Logs Level and Velocity
  • for Flow Studies
  • Includes powerful
  • Windows software for
  • Flow analysis and reporting


    Additional Information:
    • Item Code: Stingray2.0
    Yes! I am Interested
    View PDF
    Get CALLBACK

    TTFM 6.1 Transit Time Flow Meter

    TTFM 6.1 Transit Time Flow Meter
     
    Ask For Price
    Product Price:  Get Latest Price

    Product Details:
    Operating Temperature-5 deg to 140 degF (-20 deg to 60 degC)
    Accuracy+/-1% of reading from 1.5 to 40 ft/sec (0.5 to 12.0 m/sec) and +/-0.015 ft/sec (+/-0.0046 m/sec) for
    Analog outputIsolated 4-20mA / 0-5V, 1000 ohm load maximum, programmable offset
    Operating ParametersFor clean liquids in full pipes with less than 2% solids or gas bubbles
    ProgrammingBuilt-in 5-button keypad with English, French and Spanish menu language selection
    Electronics EnclosureWatertight and dust tight NEMA4X (IP 66) polycarbonate with clear, shatterproof cover
    Power Input100-240 V AC 50-60 Hz, 10 VA maximum,Optional 9-32VDC, 10 Watts maximum
    Approximate Shipping Weight12 lbs. (5.5 kg)
    ApprovalCE, CSA/UL/EN 61010-1

    Description:
    • Accurately measure the flow rate of relatively clean, non-aerated liquids like potable water, raw water, cooling water, de-ionized or reverse-osmosis water, oils and chemicals in full pipes. Ultrasonic transducers mount on the outside of a pipe without shutting down flow. Flow rate is displayed on the large, backlit display, along with total volume, signal strength, relay status, and other diagnostic values. Use the built-in control relays as flow alarms or volume totalization. Connect the isolated 4-20mA output to PLC's or controllers. A 128MB data logger is standard, capable of capturing up to 26 million data points. Optional MODBUS RTU via RS-485 available for connection to automation systems.
    • The TTFM 6.1 works on a wide range of pipe sizes and materials including carbon steel, stainless steel, ductile iron, concrete lined ductile iron, cast iron, PVC, PVDF, fiberglass, copper, brass, aluminum and pipes with bonded liners including epoxy, rubber and Teflon.
    • The TTFM 6.1 Transit Time Flow Meter operates by measuring the “transit time” or “time of flight” for ultrasonic sound pulses transmitted from one transducer to another. Depending on the mounting configuration, the signal may cross the pipe once, twice or four times. To measure flow the transit time is compared between ultrasonic signals travelling upstream and downstream.

    TTFM 6.1 Standard Features Include:
    • Enhanced Performance
    • Wide Range of Applications
    • Easy to Install and Configure
    • Non-Contacting Clamp-on Ultrasonic Transducers
    • Works on a Large Variety of Pipe Materials and Sizes
    • Large Backlit Flow Rate Display and Totalizer
    • Isolated 4-20mA Output
    • 2 Programmable Control Relays
    • Optional MODBUS® RTU or HART Output
    • Application Optimization Available
    • 128MB Data Logger
    • Plug-and-play options including MODBUS RTU output and extra control relays
    • Programming built-in 5-button keypad

    Specifications:Scope: 
    • This specification covers a Clamp-On Transit-Time Ultrasonic Flow Meter as manufactured by Greyline Instruments, Largo, Florida / Long Sault, Ontario. The meter shall provide for non-intrusive flow measurement, direction indication, volume totalizing, and transmitting of the flow rate in a full pipe.

    Performance Specifications:
    • The ultrasonic flow meter shall have an accuracy of ±1% of reading or ±0.015 ft/sec (±0.0046 m/sec), whichever is greater. Have repeatability and linearity of ±0.25%.
    • Shall operate on relatively clean liquids in full pipes with less than 2% solids or gas bubbles at flow velocities from ±0.07 to 40 ft/sec (±0.02 to 12 m/sec).
    • Operate on any metal, or plastic, sonic conducting material including carbon steel, stainless steel, ductile iron, concrete lined ductile iron, cast iron, PVC, PVDF, fiberglass, galvanized steel, copper, brass and pipes with bonded liners including epoxy, rubber and Teflon.
    • The ultrasonic flow meter shall be optimized and pre-programmed for the application when information like pipe material, pipe size, wall thickness, fluid type, fluid temperature, and max flow rate are provided at time of order.

    Transducers (Flow Sensors):
    • The flow meter shall have a dual transmitting/receiving, clamp-on transducers.
    • The transducers shall operate continuously at temperatures from -40°F to 300°F (-40°C to 150°C).
    • The standard transducer pair shall be designed to install on pipes with inside diameter ranging from 2" to 48" (50 mm to 1200 mm).
    • Have 25 ft (7.6 m) length triaxial cables from the electronics with BNC connectors to transducers.

        Additional Information:
        • Item Code: TTFM6.1
        Yes! I am Interested
        View PDF
        Get CALLBACK

        BAT 131 Bosch Battery Tester

        BAT 131 Bosch Battery Tester
         
        Ask For Price
        Product Price:  Get Latest Price

        Product Details:
        Operating Temperature0 deg C - 40 deg C
        Cca Test Range100-2000A
        Battery Nominal Voltage6V/12V
        BrandBosch
        ModelBAT 131
        ApplicationPassenger CarsC/ Commercial vehicles/SUVs/ Motorcycles
        Battery TypesStandard,AGM (flat & spiral), Gel
        Starting Charging Test System12V/24V
        WeightApprox. 700 g
        DimensionsApprox. 270 x 113 x 50 mm

        Description:
        • The new portable battery tester – BAT 131 from Bosch is perfectly suitable for testing 6V and 12V starter batteries (lead-acid, gel and fleece batteries/AGM). The load-free test procedure provides fast, precise and reliable measurement results. The battery tester has a specially designed robust housing considering workshop requirements. The enhanced user interface enables simple and intuitive operation.

        Features:
        • Load free test for 6V and 12V lead acid batteries
        • Test Range 100-2000 CCA
        • Display wrong polarity messages
        • Menu-guided intuitive operation, with results on large LCD screen
        • Stores up to 100 test reports in easily understandable excel format
        • USB port for report downloads and future software updates
        • 3M replaceable cable for flexible diagnosis
        • Testing possible in new/un-used/in-stock batteries
        • Starter and Alternator test
        • Integrated printer with latest feature for print option
         
        Benefits:
        • Easy-to-use robust housing; fast and accurate test results
        • Wide range of vehicle applications and testing norms
        • Maintain history of service records for future follow-up with customers
        • Various menu languages, “easy-to-understand” printouts for end customers
        • Updating of software is possible with USB port

        Additional Information:
        • Item Code: BAT131
        Yes! I am Interested
        Get CALLBACK

        PTFM 1.0 Portable Transit Time Flow Meter

        PTFM 1.0 Portable Transit Time Flow Meter
         
        Ask For Price
        Product Price:  Get Latest Price

        Product Details:
        Operating Temperature-5 deg to 140 deg F (-20 deg to 60 deg C)
        ApprovalsAC Charger is CE and UL approved
        Accuracy+/- 1% of reading or 0.1 ft/sec (0.03 m/sec), whichever is greater
        Operating ParametersFor clean liquids in full pipes with less than 2% solids or gas bubbles
        Electronics EnclosurePortable, ABS
        Repeatability and Linearity+/- 0.25%
        Power InputBuilt-in NiMH battery for up to 18 hours continuous operation External charger with 100-240VAC
        Outputs4-20mA (500 ohm) when powered by AC adapter
        Approximate Shipping Weight12 lbs. (5.5 kg)

        Description:
        • Recommended for fluids like water, glycol, oils and chemicals. Use it for calibrations, troubleshooting, flow surveys and as a temporary transmitter to replace inline flowmeters.
        • The PTFM 1.0 ultrasonic transducers clamp-on the outside of pipes from 2" to 48" (50 to 1200 mm) diameter. The ultrasonic signal works through common pipe materials including carbon steel, stainless steel, ductile iron, cast iron, PVC, PVDF, fiberglass, copper, brass, aluminum and pipes with bonded liners including epoxy, rubber and Teflon. Transducers can be mounted without shutting down flow and there is no obstruction or pressure drop. It measures and totalizes forward and reverse flow.
        • The PTFM 1.0 Portable Transit Time Flow Meter operates by measuring the “transit time” or “time of flight” for ultrasonic sound pulses transmitted from one transducer to another. Depending on the mounting configuration the signal may cross the pipe once, twice or four times. To measure flow the transit time is compared between ultrasonic signals travelling upstream and downstream.

        Features:
        • Non-Contacting Clamp-on Ultrasonic Transducers Works on Metal and Plastic Pipes
        • Large Backlit Flow Rate Display and Totalizer
        • Isolated 4-20mA Output
        • Built-in 5-Key Calibrator
        • 300,000 point data logger

        User-Friendly Operating System:
        • Calibration is easy with the onscreen menu system. Just enter the pipe diameter, wall thickness and pipe material. The PTFM 1.0 is powered by an internal, rechargeable NiMH battery or can be operated continuously with AC power adapter. Each PTFM 1.0 includes a watertight carry case, transducer set, cables and mounting clamps.

        Built-in Data Logger with Windows Software Included:
        • Set up the 300,000 point data logger to store time and date-stamped flow readings from 10 second to 5 minute intervals. View the convenient on-screen 'Flow Report' where total, minimum, maximum and average flow rates are stored in a 24 hour daily summary.
        • Transfer flow logs to your PC or laptop through the PTFM 1.0's USB output. Greyline Logger software (included) displays data in both graph and table formats with one-click export to Microsoft Excel®, images or CSV files for use in other programs.

        Portable Ultrasonic Flow Meter Specifications:Scope:
        • This specification covers a portable, ultrasonic Transit Time flow meter by Greyline Instruments, Largo, Florida / Long Sault, Ontario. This portable instrument shall provide for non-intrusive flow measurement, indication, totalizing and transmitting of the flow rate in a full pipe.

        General:
        • Each portable Transit Time flow meter shall have the following design features and engineering specifications:

        Performance Specifications:
        • The ultrasonic flow meter shall have an accuracy of ±1% of reading or 0.1 ft/sec (0.03 m/sec), whichever is greater. Have repeatability and linearity of ±0.25%.
        • Shall operate on clean liquids in full pipes with less than 2% solids or gas bubbles at flow velocities from ±0.07 to 39 ft/sec (±0.02 to 12 m/sec).
        • Operate on the following pipe materials: carbon steel, stainless steel, PVC, PVDF, fiberglass, galvanized steel, mild steel, ductile iron, glass, copper, brass and pipes with bonded liners including cement, epoxy, rubber and Teflon.
        • Operate on AC power or from internal, rechargeable batteries.

        Transducers:
        • The flow meter shall have a dual transmitting/receiving, clamp-on transducers operating at 1.28MHz.
        • The transducers shall operate continuously at temperatures from -40°F to 300°F (-40°C to 150°C).

        Additional Information:
        • Item Code: PTFM-1.0
        Yes! I am Interested
        View PDF
        Get CALLBACK

        SLT 5.0 Ultrasonic Level and Flow Monitor

        SLT 5.0 Ultrasonic Level and Flow Monitor
         
        Ask For Price
        Product Price:  Get Latest Price

        Product Details:
        DisplayWhite,backlit matrix displays flow rate,totalizer,relay status,operating mode and calibration menu
        Operating Temperature-5 deg to 140 deg F (-20 deg to 60 deg C)
        Accuracy+/-0.25% of Range or 2 mm (0.08'') whichever is greater, Repeatability and Linearity +/-0.1%
        OutputIsolated 4-20mA, 1000 ohm load maximum, programmable offset
        Electronics EnclosureWatertight and dust tight NEMA4X (IP 66) polycarbonate with clear, shatterproof cover
        Operating ModesLevel, Range or Open Channel Flow
        ProgrammingBuilt-in 5-key calibrator with English, French or Spanish language selection
        Power Input100-240VAC 50-60Hz (see Options), 2.4-5.6 Watts depending on options
        Electrical Surge ProtectionSensor, 4-20mA and AC power input
        Approximate Shipping Weight10 lbs. (4.5 kg)

        Description:
        • Use this versatile instrument to continuously measure, display, transmit and control liquid level in storage tanks and pumping stations, or to monitor and totalize Open Channel Flow through any flume or weir. Mount the non-contacting ultrasonic sensor above the liquid being measured and install the watertight electronics enclosure nearby. Features a user-friendly keypad calibration system, backlit LCD display, an isolated 4-20mA output and 2 programmable control relays.
        • Calibration is easy with the built-in 5 button keypad. The SLT 5.0 offers simple menu selection of measurement units (gallons, liters etc.), calculates volume in horizontal round tanks, or flow rate (and total) through any flume or weir.
        • For hazardous locations, the ultrasonic sensor is rated Intrinsically Safe with an optional safety barrier. The standard PVC and Teflon Sensor is rated for measurement ranges up to 32 ft/10 m, or select optional sensors for flange-mount or applications requiring longer measurement range. Options include 4 additional control relays (6 total) and a built-in 2-million point Data Logger with USB output to Flash memory sticks.

        Features:
        • Measure Level or Open Channel Flow
        • User-Friendly Calibration System
        • Isolated 4-20mA (1000 ohm)
        • False Echo Rejection
        • 2 Programmable Control Relays
        • Electrical Surge Protection
        • Intrinsically Safe Sensor Option
        • Plug and Play Relay and Data Logger Options

        Other Details:
        • Use it for Level: Specify SLT 5.0 for inventory monitoring and level control of chemicals, wastewater, viscous or corrosive liquids. Built-in control relays are programmable for pump control, pump alternation and level alarms. 
        • Use it for Flow: Displays, transmits and totalizes wastewater flow through any flume or weir. Features a simple, password protected calibration system, automatic totalizer and flow proportionate control relays. 
        • No maintenance Sensor: Each SLT 5.0 includes a non-contacting ultrasonic sensor which mounts above the material being measured. There is no contact and no moving parts. The sensor is sealed to withstand accidental submersion and rated for hazardous locations with optional intrinsic safety barrier.


        Additional Information:
        • Item Code: SLT-5.0
        Yes! I am Interested
        View PDF
        Get CALLBACK

        AVFM 5.0 Area Velocity Flow Monitor

        AVFM 5.0 Area Velocity Flow Monitor
         
        Ask For Price
        Product Price:  Get Latest Price

        Product Details:
        Channel TypesRound pipe, Rectangular, trapezoid, egg or custom shapes
        Electronics EnclosureWatertight and dust tight NEMA4X (IP 66) polycarbonate with clear, shatterproof cover
        AccuracyLevel +/-0.25% of Range. Velocity +/-2% of Reading. Repeatability and Linearity +/-0.1%
        DisplayWhite,backlit matrix displays flow rate, totalizer, relay states,operating mode and calibration menu
        Programmingbuilt-in 5-key calibrator with English, French or Spanish language selection
        Power Input100-240VAC 50-60Hz (see Options), 3.0-6.24 Watts depending on options
        Outputs3 Isolated 4-20mA, 1000 ohm, (Flow, Level and Velocity) or 0-5VDC by menu selection
        Electrical Surge ProtectionSensor, 4-20mA outputs and AC power input
        Operating Temperature-5 deg to 140 degF (-20 deg to 60 degC)
        Approximate Shipping Weight10 lbs. (4.5 kg)

        Description:
        • Monitor flow through open channels, partially full sewer pipes and surcharged pipes without a flume or weir. Ideal for stormwater, combined effluent, raw sewage, irrigation water and streams. Calibration is simple: enter the pipe diameter or channel shape and the AVFM 5.0 computes the flow volume and displays the flow rate. Measure forward and reverse flow and calibrate to channels of any shape.

        How It Works:
        • The AVFM 5.0 uses a submerged ultrasonic sensor to measure both Velocity and Level in the channel. The sensor is completely sealed with no orifices or ports. It mounts inside a pipe or at the bottom of a channel.

        Features:
        • For Open Channels and Pipes No Flume or Weir Required
        • Ultrasonic - Measures Velocity + Levelto Calculate Flow
        • Works in partially filled and surcharged pipes
        • 3 Isolated 4-20mA Outputs(Flow, Level and Velocity)
        • Isolated 4-20mA/0-5V Output
        • Totalizer and 2 Control Relays
        • Optional Intrinsically Safe Sensor
        • Optional built-in 2-million point Data Logger

        Other Details:
        • Area-Velocity Flow Meter: Monitor flow through open channels, partially full sewer pipes and surcharged pipes without a flume or weir. Ideal for municipal stormwater, combined effluent, raw sewage and irrigation water.
        • Submersible Ultrasonic Sensor: The AVFM 5.0 uses a submerged ultrasonic sensor to continuously measure both Velocity and Level in the channel. The sensor resists fouling, corrosion and abrasion. The flowmeter can be configured with the standard submerged velocity-level sensor, or with submerged velocity plus a separate non-contacting ultrasonic level sensor.
        • View flowrate and total flow on the large backlit LCD display and connect to external devices with three 4-20mA outputs and two control relays.

          Additional Information:
          • Item Code: AVFM-5.0
          Yes! I am Interested
          View PDF
          Get CALLBACK

          DFM 5.1 Doppler Flow Meter

          DFM 5.1 Doppler Flow Meter
           
          Ask For Price
          Product Price:  Get Latest Price

          Product Details:
          Accuracy+/- 2% of reading or 0.05 ft/sec (0.015 m/sec). Requires solids or bubbles minimum
          CalibrationBuilt-in 5-key calibrator with English, French or Spanish language selection
          OutputIsolated 4-20 mA (1000 ohm load max.)
          Power Input9-32 V DC
          Control Relays4 additional (6 total) rated 5 ampere SPDT
          Enclosure HeaterFor outdoor installation, 16 watt thermostatically controlled to -40 deg F (-40 deg C)
          Data LoggerBuilt-in 2 million point logger with output and Windows software
          Flow Rate Range+/-0.1 +/-0.03 to 40 ft/sec ( to 12.2 m/sec) in most applications
          Pipe SizeAny pipe from 1/2'' to 180'' (12.7 mm to 4.5 m) ID

          Description:
          • Measure flow from outside a pipe. The Greyline DFM 5.1 is designed for "difficult liquids" that would damage regular flow meters - wastewater, slurries, sludge, chemicals, viscous liquids and abrasives. There is no obstruction to flow and no pressure drop. The non-intrusive, clamp-on ultrasonic sensor fits any pipe 1/2" (12.5 mm) Inside Diameter or larger. The electronics/display enclosure can be mounted nearby.
          • Use the isolated 4-20mA to transmit flow to remote displays, recorders or controllers. The programmable relays can be used for flow control, pump protection or flow proportionate pulse. Calibration is easy with the built-in 5-key calibrator. Display and totalize flow in your choice of engineering units (gallons, liters etc.)
          • Sensor cable can be extended up to 500 ft. (152 m) with no loss of signal. The standard sensor is rated non-incendive for Class I, Division 2 hazardous locations and the DFM 5.1 can be equipped with optional Intrinsic Safety Barriers for sensor installation in Class I, Division I hazardous locations. Other options include extra control relays and a built-in 2 million point Data Logger with USB output to Flash Drives.
          • The DFM 5.1 includes a new digital signal processor to filter background noise and interference, and to measure flow rates accurately in liquids containing gas bubbles or solids particles.


          Features:
          • Non-Contacting Ultrasonic Sensor
          • Accurate and Verifiable
          • Built-in 2-million point Data Logger and Windows Software
          • USB Outputs to Flash Memory Sticks
          • Simple 5-key Calibration with Language Selection
          • Isolated 4-20mA/0-5V Output
          • 2 Programmable Control Relays

          Doppler Flow Meter Specifications:
          • Scope: This specification covers a non-intrusive, ultrasonic Doppler-type flow meter as manufactured by Greyline Instruments Inc., Largo, Florida / Long Sault, Ontario. The instrument shall provide for velocity or volumetric indicating and transmitting of the flow rate in a full pipe.

          Performance Specifications:
          • The flow meter shall operate with a single-head flow sensor mounted externally on any contiguous pipe material that conducts sound including: carbon steel, stainless steel, ductile iron, copper, FRP, PVC, ABS, or cement lined pipe from 1/2" to 180" (12.5 mm to 4.5 m) ID.
          • Measure and indicate flow rates from +0.25 to +40 ft/sec and -0.25 to -40 ft/sec (+0.075 to +12.2 m/sec and -0.075 to -12.2 m/sec) with accuracy of ±2% of reading on liquids with entrained particles or gases of 100 microns or larger and minimum concentrations of 75 ppm.

          Transducer (Flow Sensor):
          • The flow sensor shall be single-head, ultrasonic in a stainless steel housing. It shall be installed on the outside of a pipe without interrupting flow. The sensor shall be capable of continuous operation at temperatures from -40°F to 300°F (-40°C to 150°C), and to withstand accidental submersion pressures to 10 psi. Manufacturer's recommended coupling compound and stainless steel mounting clamp shall be included.
          • Shall include 20 ft (6m) Sensor cable, shielded coaxial pair.
          • Shall be capable of extending sensor cable up to 500 ft (152m) without requirement for operator adjustment.
          • Shall be transformer isolated and designed to meet intrinsic safe requirements. Shall be designed for maximum RFI rejection, and include automatic high voltage bleeds for nearby lightning strikes.
          • Sensor shall be rated Non-incendive for Class I, Division 2, Groups A, B, C & D locations.

          Additional Information:
          • Item Code: DFM-5.1
          Yes! I am Interested
          View PDF
          Get CALLBACK

          PSL 5.0 Hybrid Pump Station Level Controller

          PSL 5.0 Hybrid Pump Station Level Controller
           
          Ask For Price
          Product Price:  Get Latest Price

          Product Details:
          DisplayWhite, backlit matrix - displays calibration menu, relay status, runtime reports and sensor status
          Operating TemperatureElectronics -5 to 140 deg F (-20 to 60 deg C)
          Accuracy+/-0.25% of Range or 2 mm (0.08'') whichever is greater
          CalibrationLevel or Range mode in selectable units
          Electronics EnclosureWatertight, dust tight NEMA4X (IP 66) polycarbonate with a clear, shatter-proof face
          Power Input100-240VAC 50-60Hz (see Options), 3 Watts maximum (with standard features)
          Surge ProtectionAC power, 4-20mA and ultrasonic sensor
          OutputsIsolated 4-20mA (1000 ohm)
          ProgrammingBuilt-in, 5-button keypad, password-protected

          Description:
          • Ideal for Level Control: Designed for pump stations, wet wells and tank level control the new Greyline PSL 5.0 Pump Station Level Controller has six independently programmable control relays for pump or valve control, level alarms, autodialers, temperature or fault alarms.
          • No contact, No maintenance: Mount the non-contacting, ultrasonic sensor in the tank or wet well and install the watertight electronics in the control room or any location within 500 ft / 150 m. Use the simple menu system and built-in keypad to set up measurement range, relay set points and pump alternation sequence. A relay/pump run time report is updated and stored automatically for viewing on the instrument’s backlit LCD display
          • New Dual-Technology Sensor Feature Redundant Level Sensing: Connect a submersible pressure sensor or other 4-20mA level transmitter
          • to the PSL 5.0 for fail-safe hybrid sensing. The PSL 5.0 will auto-calibrate the redundant sensor and if signal is lost to the ultrasonic sensor, the redundant sensor will seamlessly take over monitoring until signal resumes from the ultrasonic. The redundant sensor is continuously monitored to ensure availability during primary sensor failure.

          Features:
          • Non-Contacting Ultrasonic Sensor
          • Accepts Pressure Sensor Input for Redundant Monitoring
          • 6 Control Relays with Programmable Pump Alternation
          • Automatically Logs and Reports Relay Run Times for Pump
          • Performance Evaluation
          • Plug and Play Optional Data Logger
          • Isolated 4-20mA Output


          Additional Information:
          • Item Code: PSL-5.0
          Yes! I am Interested
          View PDF
          Get CALLBACK

          DLT 2.0 Differential Level Transmitter

          DLT 2.0 Differential Level Transmitter
           
          Ask For Price
          Product Price:  Get Latest Price

          Product Details:
          Accuracy+/-0.25% of Range or 2 mm (0.08'') whichever is greater, Repeatability and Linearity+/-0.1%
          Electronics EnclosureWatertight and dust tight NEMA4X (IP 66) polycarbonate with clear, shatterproof cover
          ProgrammingBuilt-in 5-key calibrator with English, French or Spanish language selection
          Power Input100-240VAC 50-60Hz (see Options), 3 Watts maximum (with standard features)
          Electrical Surge ProtectionSensor, 4-20mA outputs and AC power input
          Operating Temperature-5 deg to 140 deg F (-20 deg to 60 deg C)
          Approximate Shipping Weight15 lbs. (6.8 kg)

          Description:
          • Reduce costs and simplify instrumentation at treatment plant headworks. The DLT 2.0 can measure both differential level plus flow through a flume. Install one Sensor on each side of a mechanical barscreen to continuously monitor, transmit and control level. Use the built-in control relays or 4-20mA outputs to automatically activate the barscreen rake at preset levels.
          • The DLT 2.0 is a simple solution for barscreen level control at wastewater treatment plants, pump stations and combined sewer systems. It includes two non-contacting ultrasonic sensors to measure level. With sensors positioned above a channel, up and downstream from the barscreen, the DLT 2.0 can display and transmit differential level. The downstream sensor can also be installed above a flume or weir to measure and totalize open channel flow.
          • Three 4-20mA outputs are configured to transmit upstream level, downstream level (or flow) and differential level. Built-in relays can be calibrated for level control, differential level control or open channel flow.
          • Other DLT 2.0 applications include two-tank inventory where you can monitor level in two tanks with one instrument. The DLT 2.0 will alternate display of level in both tanks plus transmit 4-20mA outputs. Use the built-in relays to activate alarms or level controls. This versatile dual-sensor instrument can also be configured as a submergence alarm for Parshall flumes.

          Features:
          • Measures Level, Differential Level and Open Channel Flow
          • Two Non-Contacting Ultrasonic Sensors
          • Large White Backlit LCD Display
          • Three Isolated 4-20mA Outputs
          • Built-in 5-Key Calibration
          • 2 Programmable Control Relays
          • Optional 2 Million Point Data Logger
          • Optional Intrinsically Safe Sensors

          Other Details:
          • Versatile, Easy to Use: Install one Sensor on each side of a barscreen to continuously monitor, transmit and control level. Use the built-in control relays or 4-20mA outputs to automatically activate the barscreen rake at preset levels.
          • One Instrument Does the Work of Three: The DLT 2.0 is a simple solution for barscreen level control at wastewater treatment plant headworks, pump stations and combined sewer systems. It includes two non-contacting ultrasonic sensors to measure level. With sensors positioned above a channel, up and downstream from the barscreen, the DLT 2.0 can display and transmit differential level. The downstream sensor can also be installed above a flume or weir to measure and totalize open channel flow.
          • Three 4-20mA outputs are configured to transmit upstream level, downstream level (or flow) and differential level. Built-in relays can be calibrated for level control, differential level control or open channel flow.


            Additional Information:
            • Item Code: DLT-2.0
            Yes! I am Interested
            View PDF
            Get CALLBACK

            OCF 5.0 Open Channel Flow Monitor

            OCF 5.0 Open Channel Flow Monitor
             
            Ask For Price
            Product Price:  Get Latest Price

            Product Details:
            DisplayWhite,backlit matrix displays flow rate,totalizer,relay status,operating mode and calibration menu
            Operating Temperature-5 deg to 140 deg F (-20 deg to 60 deg C)
            Accuracy+/-0.25% of Range or 2 mm (0.08'') whichever is greater, Repeatability and Linearity+/-0.1%
            OutputIsolated 4-20mA/0-5V, 1000 ohm load maximum, programmable offset
            Electronics EnclosureWatertight and dust tight NEMA4X (IP 66) polycarbonate with clear, shatterproof cover
            ProgrammingBuilt-in 5-key calibrator with English, French or Spanish language selection
            Power Input100-240VAC 50-60Hz (see Options), 2.95-5.6 Watts depending on options
            Electrical Surge ProtectionSensor, 4-20mA and AC power input
            Approximate Shipping Weight10 lbs (4.5 kg)

            Description:
            • Continuously monitor, display, totalize and data log flow through any flume or weir. The OCF 5.0 includes a non-contacting ultrasonic sensor that mounts just 8" (203.2 mm) above the flowing water. It is accurate (±0.25%) and reliable. There is no obstruction to flow and no fouling. Use the built-in Keypad/menu system to select your flume or weir from the Menu and to choose measurement units (gallons, liters etc.)
            • The Greyline OCF 5.0 includes built-in 2-million point Data Logger and flow reporting system. Connect a flash memory stick to the flowmeter's USB output to download log files and then view your data in graph and table formats with 'Greyline Logger' software – supplied free with each OCF 5.0. Daily flow reports including minimum, maximum, average and total daily flow can be viewed directly on the backlit OCF 5.0 LCD display. New! Logger Download to USB Flash Drive
            • Use the isolated 4-20mA to transmit flow to remote chart recorders or displays, and the control relays are programmable for level/flow alarm, and flow proportionate pulse (for samplers, chlorinators or remote totalizers). An Intrinsic Safety Barrier is optional for sensor and cable installation in hazardous rated locations. The separate, watertight electronics/display enclosure is mounted at a convenient location within 500 ft (150 m) of the sensor.

            Features:
            • Non-Contacting Ultrasonic Sensor
            • Large, Backlit LCD Display
            • 12-Digit Totalizer
            • Isolated 4-20mA (1000 ohm)
            • 2 Programmable Control Relays
            • Automatic Sensitivity Adjustment
            • Built-in 5-Key Calibrator
            • Optional 2 million point Data Logger with USB output to Flash memory

            Other Details:
            • Non-Contacting Sensor: The OCF 5.0 uses a non-contacting ultrasonic sensor mounted over a flume or weir to measure flow. It is accurate, reliable and verifiable. The separate, watertight electronics/display enclosure can be mounted within 500 ft (150 m) of the sensor. The OCF 5.0 continuously displays, totalizes, transmits and data logs open channel flow.
            • Keypad Operating System: Use the built-in keypad for fast, easy calibration with menu selection of flume or weir and measurement units (e.g. gallons, liters etc.) Calibration values and data logs are password-protected and retained during power interruptions. The OCF 5.0 will display on-screen flow reports with daily total, minimum, maximum and average flow and will transfer data logs to a USB flash drive. PC software is included.

              Additional Information:
              • Item Code: OCF-5
              Yes! I am Interested
              View PDF
              Get CALLBACK

              Area Velocity Flow Monitor

              Area Velocity Flow Monitor
               
              Ask For Price
              Product Price:  Get Latest Price

              Product Details:
              BrandGreyline
              DisplaysFlow Rate Large 4-digit LCD - Totalizer/Menu/Status - 16-digit alphanumeric
              Sensor Cable25 ft / 7.6 m submersible, shielded 3-coaxial
              EnclosureWwatertight, NEMA4X (IP66) polycarbonate
              Power Input100-160 VAC 50/60 Hz
              Electrical Surge Protection and RFI FiltersAC, sensor, 4-20 mA

              As a well-known trader and supplier in this domain, we are offering high quality Area Velocity Flow Monitor. Flow monitor offered by us is designed and manufactured by our vendors utilizing optimum quality raw material and latest technology. Rigorously tested on quality parameters to ensure its flawlessness, this flow monitor is obtainable in various specifications at most competitive price range.

              Features:
              • QZ02L sensor: Measures flow Velocity and Level
              • Calibration: Built-in 3-key programmer
              • Output: Three isolated 4-20mA (1000 ohm), Flow, Level and Velocity
              • 2 control relays: 5 amp, SPDT - programmable for flow proportional pulse output, flow and/or level alarm
              • 1 Manual: Installation and Operation

              Area-Velocity Flow Monitor Specifications:Scope:
              • This Specification Covers An Ultrasonic, Area-Velocity Flow Monitor As Manufactured By Grey line Instruments, Massena, New York / Long Sault, Ontario. The Instrument Shall Provide For Indicating, Transmitting, Totalizing Of The Flow Rate Through Partially Filled Or Surcharged Round Pipes Or Rectangular, Trapezoidal And Egg-Shaped Channels.

              General:
              • Flow Monitor To Consist Of A Submersible Ultrasonic Sensor, Connecting Cable, And Remote Enclosure With Indicating, Transmitting And Controlling Electronics. System Shall Have No Moving Parts
              • Level Measurement Accuracy Shall Be ±0.25% Of Range. Velocity Measurement Accuracy Shall Be ±2% Of Reading

              Sensing Element:
              • Ultrasonic Sensor Shall Be Designed For Continuous Submersion In Liquids
              • Using The Doppler Principle, The Sensor Shall Measure Fluid Velocities From 0.1 To 20 Ft/Sec (0.03 To 6.2 M/Sec)
              • Using Ultrasonic Echo-Ranging Principle, The Submerged Sensor Shall Measure Liquid Level From 1" To 15 Ft. (25.4 Mm To 4.57 M). Minimum Level Shall Not Be Greater Than 1" (25.4 Mm). Level Sensing Circuitry Shall Include A Temperature Sensor For Automatic Temperature Compensation
              • Sensor Shall Be Constructed Of Pvc And Epoxy Resin
              • Sensor Operating Temperature Shall Be 5°F To 150°F (-15°C To 65°C)

              Additional Information:
              • Item Code: AVFM-II
              Yes! I am Interested
              Get CALLBACK

              Portaflow PT400 Portable Transit Time Flow Meter

              Portaflow PT400 Portable Transit Time Flow Meter
               
              Ask For Price
              Product Price:  Get Latest Price

              Product Details:
              Accuracy+/-2% of reading in most applications
              Repeatability+/-0.5%
              Fluid ApplicationRecommended for clean liquids with less than 2% solids or gas bubbles
              Flow Rate Range0.65 to 40 ft/sec (0.2 to 12 m/sec)
              Pipe Size'A' Transducers - 0.51'' to 4.5'' Outside Diameter (13 mm to 115 mm)
              Pipe Wall Thickness0.039 - 2.95'' (1 - 75 mm)
              Totalizer12 digits - displays separate forward and reverse flow totals
              Outputs0/4-20mA, 5V pulse (1 pulse/sec maximum)
              Data LoggerNot available (see model PT500)
              Electronics EnclosureRated IP54, ABS portable
              Carry CasePolypropylene with protective molded foam insert

              Description:
              • Recommended for clean fluids like water, glycol, oil and most chemicals. Sensors can be mounted without shutting down flow and there is no obstruction or pressure drop. The ultrasonic signal travels through all common metal and plastic pipe materials. Flow rate and totalizer are displayed continuously along with battery status, signal strength. Press one key to instantly change the units of flow measurement (e.g. from gallons to liters). Real time flow can be displayed in large numeric values or as a graph.
              • Portaflow calibration is easy with the onscreen menu system. Enter the pipe diameter, wall thickness and pipe material, and the PT400 calculates the optimum mounting method and separation distance for the sensors.
              • The Portaflow PT400 ultrasonic sensors clamp on the outside of vertical or horizontal pipes. Select a Sensor pair for the range of pipe sizes you will monitor:

              Select a Sensor pair for the range of pipe sizes you will monitor:
              • Transducers for 0.51" to 4.5" Outside Diameter (13 to 115 mm) or Transducers for 2” to 39.37” Outside Diameter (50 to 1000 mm)
              • Calibration parameters can be stored for up to twenty different sites so that operators can recall calibration setups from the Portaflow memory. Use the 5V pulse or 4-20 mA output to transmit to external devices like data loggers or recorders. The P400 includes 'A' or 'B' sensor pairs, stainless steel guide rail and mounting clamps, sensor cables, coupling compound and AC charger with a rugged polypropylene carry case. It operates up to 16 hours from internal batteries and recharges overnight.

              Features:

              • Clamp-on Ultrasonic Sensors
              • Choose Small Pipe or Large Pipe Sensors
              • Internal Battery and/or AC Powered
              • Easy Calibration and Set-up
              • Flow Proportionate Pulse Output
              • 4-20 mA Output

              Portable Ultrasonic Flow Meter Specifications:Scope:
              • This specification covers a portable, ultrasonic Transit Time flow meter by Greyline Instruments, Largo, Florida / Long Sault, Ontario. This portable instrument shall provide for non-intrusive flow measurement, indication, totalizing and transmitting of the flow rate in a full pipe.

              General:
              • Each portable Transit Time flow meter shall have the following design features and engineering specifications:

              Performance Specifications:Have an accuracy of ±2% of reading in most clean fluid applications. Have repeatability of ±0.5%.
              • Operate on clean liquids in full pipes with less than 2% solids or gas bubbles.
              • Operate on any sonic conducting pipe material such as carbon steel, stainless steel, galvanized steel, mild steel, copper, UPVC, PVDF, glass, brass and including pipes with bonded liners of epoxy, rubber or cement.
              • Operate on AC/DC power. Include an internal NiMH rechargeable battery with capacity for 16 hours continuous battery operation. Recharge and operate with power input of 100-260VAC 50-60Hz.
              • Ultrasonic Transducers:
              • Have a dual 2 MHz transmitting/receiving, clamp-on transducers.
              • The transducers shall be waterproof and operate continuously at temperatures from -4°F to 275°F (-20°C to 135°C).
              • The transducers shall be designed to install on pipes with inside diameter ranging from 0.51" to 4.5" OD (13 mm to 115 mm).
              • Have a 6 ft (2 m) long cable from the transducers to the electronics.
              • Shall include manufacturer's recommended sensor coupling compound.
              • Shall include stainless steel sensor mounting guiderails with clamps permitting installation and removal of transducers.
              • Shall include a transducer test block to allow the transducers and inter-connecting cables to be functionally checked.

              Additional Information:
              • Item Code: PT400
              Yes! I am Interested
              View PDF
              Get CALLBACK

              DFS 5.1 Doppler Flow Switch

              DFS 5.1 Doppler Flow Switch
               
              Ask For Price
              Product Price:  Get Latest Price

              Product Details:
              Shipping Weight8 lbs (3.6 kg)
              EnclosureWatertight, dust tight NEMA4X (IP 67) polycarbonate with a clear shatter-proof face
              Power Input100-240 V AC 50-60 Hz (+/-10%), 2 Watts
              Control Relay5 ampere DPDT
              Set PointsON/OFF adjustment from 0.25 to 10 ft/sec (0.075 to 3 m/sec)
              SensorSingle-head ultrasonic with 20 ft (6m) shielded cable
              Pipe SizeAny pipe ID from 1/2'' to 180'' (12.5 mm to 4.5 m)
              Sensor Operating Temperature-40 deg to 300 deg F (-40 deg to 150 deg C)
              Electronics Operating Temperature-10 deg to 140 deg F (-23 deg to 60 deg C)
              Accuracy+/-2%, requires solids or bubbles minim

              Description:Flow Switch With Non-Contacting Sensor:
              • Control Flow from outside a pipe. Recommended for "difficult liquids" including wastewater, cooling water, slurries, sludge, chemicals, viscous liquids and abrasives. The Greyline DFS 5.1 is ideal for pump protection or to activate flow/no-flow alarms.

              Easy to Calibrate:
              • The DFS 5.1 control relay can be set to turn ON and OFF at any flow rate between 0.25 and 10 ft/sec (0.075 to 3 m/sec). Insert two links for separate ON/OFF set points or just one link for a Hi or Lo flow alarm. Set the relay actuation time delay from 0 to 80 seconds.
              • A bright LED indicator shows the relay state and a LED bargraph shows the flow rate. Electronics are housed in a watertight polycarbonate wall-mount enclosure.
              • The clamp-on ultrasonic sensor mounts on the outside of metal or platic pipes without cutting the pipe or shutting down flow. It works on any pipe diameter 1/2" (12.5 mm) or larger and installs in minutes. There are no moving parts and no maintenance is required. The shielded sensor cable length is 20 ft. (6 m) and can be extended up to 500 ft. (152 m) with an optional Junction Box.

              Doppler Flow Switch Specifications:Scope:
              • This specification covers a non-intrusive, ultrasonic Doppler-type flow switch as manufactured by Greyline Instruments Inc., Largo, Florida / Long Sault, Ontario. The instrument shall provide for flow control at adjustable flow velocities.

              Performance Specifications:
              • The flow switch shall operate with a clamp-on ultrasonic sensor mounted externally on any contiguous pipe material that conducts sound including: carbon steel, stainless steel, ductile iron, copper, FRP, PVC, ABS, or cement lined pipe from 1/2" to 180" (12.5 mm to 4.5 m) diameter.
              • Shall operate on liquids with entrained particles or gases of 100 microns or larger and minimum concentrations of 75 ppm.
              • The control ON and OFF set-points shall be independently adjustable for flow rates between 0.25 ft/sec (0.076 m/sec) and 10 ft/sec (3 m/sec).

              Transducer (Sensing Element):
              • The flow sensor shall be single-head, ultrasonic in a stainless steel housing. It shall be installed on the outside of a pipe without interrupting flow. The sensor shall be capable of continuous operation at temperatures from -40°F to 300°F (-40°C to 150°C), and to withstand accidental submersion pressures to 10 psi.
              • Manufacturer's recommended coupling compound and stainless steel pipe clamp shall be included.
              • Shall connect to separate electronics housing with 20 ft (6m) shielded coaxial cable pair with waterproof, potted bond to the Sensor head.
              • Shall be capable of extending sensor cable up to 500 ft (152m) without adjustment and with no reduction in performance or signal strength.

              Electronics/Controller:
              • Shall be housed in a wall-mount watertight, dust tight NEMA4X (IP 66) polycarbonate enclosure with a gasketed shatter proof window.
              • Have a power input of 100–240VAC 50-60Hz (±10%), 2.0 W Max.
              • Shall include one 5 ampere DPDT control relay.
              • Shall operate in Hi or Lo alarm mode, or with separate ON/OFF set points individually adjustable between 0.25 and 10 ft/sec (0.076 to 3 m/sec).
              • The controller shall include an indicator LED to display relay status and a LED bargraph to display flow rate.
              • The controller shall include relay time delay adjustment from 0 to 80 seconds.
              • The flow switch electronics/controller shall operate at temperatures from -10° to 140°F (-23° to 60°C).
              • Shall be designed for maximum RFI rejection.

              Additional Information:
              • Item Code: DFS-5.1
              Yes! I am Interested
              View PDF
              Get CALLBACK

              BAT 110 Battery Tester

              BAT 110 Battery Tester
               
              Ask For Price
              Product Price:  Get Latest Price

              Product Details:
              BrandBosch
              ModelBAT 110
              Weight295 g
              Test MethodNon-loading
              Voltmeter Measuring Range5.5 - 19.99 V DC
              Diagnostic CapabilitiesCharging system test
              Display4-digit numeric display and 3 LED indicators
              User InterfacePush-button operation
              Cable0.4 m
              Dimensions197 mm x 98 mm x 40 mm (W x H x D)

              Description:
              • BAT 110 is the ideal all-rounder for fast, uncomplicated and reliable battery tests. Thus, it is ideally suited for automotive workshops, used car dealers, car fleets, and paint and body workshops as well as for roadside assistance.

              Features:
              • “No Load” battery tester for 12V starter batteries
              • Capable of testing lead acid batteries (AGM,GEL, Standard, Maintenance free)
              • Capable of testing 12V starter and Alternator
              • Four digit LED screen displays the testing voltage
              • Three LED indicators to show the status of battery
              • Offer wide range of testing norms like SAE/EN/DIN/IEC/CCA
              • A conversion table for JIS norm attached in the back side of the tester

              Operating range:
              • 200 A to 900 A acc. to SAE / EN
              • 120 A to 550 A acc. to DIN / IEC
              • 200 A to 850 A acc. to CCA JIS conversion table provided on the rear of the device

              Test state and battery charge state, battery diagnostics:
              • Battery charge state, battery diagnostics Voltmeter, starter system test

              Additional Information:
              • Item Code: BAT110
              Yes! I am Interested
              Get CALLBACK

              Radar type Level Indicator Transmitter

              Radar type Level Indicator Transmitter
               
              Ask For Price
              Product Price:  Get Latest Price

              Product Details:
              Output Signal4~20 mA/HART
              Ambient Temperature-40~+60
              Damping Period0~32 s adjustable
              Power11~28.6 VDC (intrinsically-safe), 11~36 VDC (explosion proof)
              Pressure25 kg/cm2 high pressureLess than and equal to MPa(i.e. 326 kg/cm2)
              EnclosureIP-67
              Load Resistance65 ohm
              Repetition2 mm
              Data Updated30 ms
              Humidity0~99% RH

              By keeping track with the market development, we have been able to trade and supply a premium quality Radar Type Level Indicator Transmitter. Offered transmitter is designed and manufactured using exceptional quality raw material and highly developed technology at our vendor’s hi-tech manufacturing unit. In addition, this transmitter is obtainable in standard and customized options as per the particular requirements of the clients.

              Features:
              • Optimum performance
              • Reliability
              • Low maintenance cost
              • Longer functional life

              Product Details:
              • Medium Density: normal temperature<=100, middle temperature 210, high temperature <=520
              • Electric interface: default M 20 x 1.5, or as per customer request.
              • Output accuracy: analogue:0.01 mA, Display: when measuring range <10 m Analog display is 1mm, when range >10 m is 10 mm.
              • Precision: coaxial type 0.1% FS, other 5 mm
              • Temperature influence: probe length change(-0.02%) as temperature change one centigrade User interface: 3 key+ LCD display
              • Linearity: coaxial type/dual rod:<=0.1% probe length; Single rod:<=0.3% probe length
              • Fault-diagnosis, warning: 3.6 mA, 22 mA, Hold

              Yes! I am Interested
              Get CALLBACK

              Pump Station Level Controller

              Pump Station Level Controller
               
              Ask For Price
              Product Price:  Get Latest Price

              Product Details:
              BrandGreyline
              DisplaysLevel large 4-digit LCD; Menu/Reports/Status 16-digit alphanumeric
              SensorPZ 34, PVC, 32 ft / 10 m range
              Sensor Cable25ft / 7.6m coaxial
              Power Input100-130 VAC 50/60 Hz, 8 watts maximum

              Our immense domain expertise and market knowledge assist us to trade and supply the finest quality Pump Station Level Controller. Our vendors’ experts design and manufacture this level controller utilizing higher quality raw material at par with industry standards. The manufacturing process of this level controller is vigilantly examined at each step to ensure its dependability. Also, offered level controller is available in various specifications to our precious clients as per their precise requirement.

              Features:
              • Temperature compensation: Automatic
              • Enclosure: Watertight, dust tight NEMA 4 X (IP 66) polycarbonate
              • Programming: Built-in 3 button keypad, Password protected and "PSL Remote" Windows software
              • Calibration: Level or Range mode in selectable units
              • 6 relays: 5 ampere SPDT, programmable alarm and/or pump control modes, pump alternation/sequencing, failsafe/echo-loss, sensor temperature alarm
              • Outputs: Isolated 4-20 mA (1000 ohm), RS232
              • Report logger: Pump Run Time report
              • Electrical surge protection: Sensor, AC power, 4-20 mA and RS 232 outputs
              • 1 PC software: "PSL Remote" for Windows™ - calibrate and save as disk file, real-time PSL monitoring by RS 232 or modem connection
              • 1 Manual: Installation and Operation

              Pump Station Level Controller Specifications:Scope:
              • This specification covers a non-contacting ultrasonic Pump Station Level Controller as manufactured by Grey line Instruments, Massena New York / Long Sault, Ontario. This instrument shall provide for indicating, transmitting of wet well or tank level, and control of up to six pumps or alarms.

              General:
              • Pump Station Level Controller to consist of an non-contacting ultrasonic sensor, connecting cable, and a remote enclosure with indicating, transmitting and controlling electronics
              • Measurement accuracy shall be ±0.25% of Range or 2 mm (0.08"), whichever is greater, and shall be automatically temperature compensated
              • Sensor cable length shall be as required by installation, not to exceed 500' (152 m)
              • System shall have no moving parts and shall not contact the material being measured
              • Shall include a built-in keypad and simple menu system for calibration, and Windows™ software for calibration and monitoring by modems or direct RS232 connection

              Sensing Element:
              • Sensor shall be constructed of PVC
              • The sensor shall have a minimum dead band or blanking of 16" (407 mm) and a maximum range of 32 ft. (10 m), and have an operating frequency of 46 kHz with an ultrasonic beam angle of 8 Degrees
              • Sensor shall withstand accidental submersion to 20 psi
              • Sensor operating temperature shall be from -40°F to 150°F (-40°C to 65°C)
              • Sensor shall include integral temperature sensor. Temperature sensors requiring separate mounting and wire runs shall not be accepted

              Sensor Connecting Cable:
              • Provide RG 62 AU coaxial cable 25' (7.6 m) continuous length, with waterproof, potted bond to the Sensor head
              • Extended sensor cable shall be RG 62 AU coaxial to a maximum of 500' (152 m). Cable shall be spliced with screw terminal connections in manufacturer's recommended steel NEMA 4 Junction Box
              • Level and temperature signals shall be conducted on one single coaxial cable. Separate or multiple-conductor cables shall not be accepted
              • Sensor cable shall be installed in grounded metal conduit

              Additional Information:
              • Item Code: PSL
              Yes! I am Interested
              Get CALLBACK

              Transit Time Flow Meter for Clean Liquid

              Transit Time Flow Meter for Clean Liquid
               
              Ask For Price
              Product Price:  Get Latest Price

              Product Details:
              DisplayWhite, back light matrix
              BrandGreyline
              Totalizer14 digits
              CalibrationBuilt-in 5-key programmer
              OutputIsolated 4-20 mA (1000 ohm)

              Transit Time Flow Meter for Clean Liquid Accurately measure the flow rate of clean, non-aerated liquids like water, chemicals, and oils in full pipes. Ultrasonic transducers mount on the outside of a pipe without shutting down flow. Flow rate is displayed on the large, back light display along with totalizer and signal strength. Use the built-in control relays for flow alarms or flow proportionate pulse. Connect the isolated 4-20 mA output to PLC's or controllers. The TTFM 1.0 works on a wide range of pipe sizes and materials including carbon steel, stainless steel, ductile iron, cast iron, PVC, PVDF, fiberglass, copper, brass, aluminum and pipes with bonded liners including epoxy, rubber and Teflon. The TTFM 1.0 Transit Time Flow meter operates by measuring the “transit time” or “time of flight” for ultrasonic sound pulses transmitted from one transducer to another. Depending on the mounting configuration, the signal may cross the pipe once, twice or four times. To measure flow the transit time is compared between ultrasonic signals traveling upstream and downstream.

              Features:
              • Non-Contacting Clamp-on Ultrasonic Transducers
              • Works on Metal and Plastic Pipes
              • Large Back light Flow Rate Display and Totalizer
              • Isolated 4-20 mA Output
              • Built-in 5-Key Calibrator
              • 2 Programmable Control Relays
              • Optional 20 Million Point Data Logger

              Product Details:
              • pair SE16B ultrasonic transducers - clamp-on for 1/2” to 48” (12 mm to 1200 mm) pipes and rated nonincendive for Class I, Division 2, Groups A, B, C & D locations
              • Sensor cables - pair 25 ft / 7.6 m coaxial with BNC connectors
              • Flow rate range: ± 0.07 to 39 ft/sec (± 0.02 to 12 m/sec)
              • Installation - stainless steel transducer mounting brackets and clamps, alignment bar and silicone coupling compound kit
              • Enclosure - watertight, NEMA4X (IP66) polyester and polycarbonate
              • 2 control relays - 5 amp, SPDT - programmable for flow proportional pulse output, and/or flow alarm
              • Plug-and-play options including data logger and extra control relays
              • Electrical surge protection and RFI filters - AC, sensor, 4-20 mA

              Additional Information:
              • Item Code: TTFM-1
              Yes! I am Interested
              Get CALLBACK

              Open Channel Flow Monitor

              Open Channel Flow Monitor
               
              Ask For Price
              Product Price:  Get Latest Price

              Product Details:
              BrandGreyline
              Time DelayAdjustable, 0-60 seconds
              Power Input120 VAC 50/60 Hz
              EnclosureWatertight NEMA4X (IP 67) polycarbonate
              Sensor Cable20ft (6 m) shielded coaxial pair

              Features:
              • Sensor: Strap-on, single head ultrasonic
              • Installation: Sensor compound kit and stainless steel pipe clamp
              • 1 relay: 5 amp DPDT
              • Set point: ON/OFF adjustment 0.25 to 10 ft/sec (0.076 to 3 m/sec)
              • Failsafe mode: Switch selectable
              • Indication: Relays and signal strength LED's
              • Sensitivity: Adjustable
              • Electrical surge protection
              • 1 manual: Installation and Operation

              Open Channel Flow Monitor Specifications:Scope: 
              • This Specification Covers An Ultrasonic, Echo-Ranging Type Open Channel Flow Meter As Manufactured By Grey line Instruments, Massena, New York / Long Sault, Ontario. This Instrument Shall Provide For Indicating, Transmitting, Totalizing And Data Logging Of The Flow Rate Through A Flume, Weir, Or Other Primary Measuring Device.

              General:
              • Flow Monitor To Consist Of An Non-Contacting Ultrasonic Sensor, Connecting Cable, And A Remote Enclosure With Indicating, Transmitting, Controlling And Data Logging Electronics
              • Measurement Accuracy Shall Be ±0.25% And Shall Be Automatically Temperature Compensated
              • Sensor Cable Length Shall Be As Required By Installation, Not To Exceed 500 Ft (152 M)
              • System Shall Have No Moving Parts And Shall Not Contact Flowing Water

              Sensing Element:
              • Sensor Shall Withstand Accidental Submersion To 20 Psi
              • Sensor Minimum Range Shall Be 8" (203.2 Mm) And Maximum Range Shall Be 15 Ft (4.57 M)
              • Sensor Shall Be Constructed Of Pvc
              • Sensor Operating Temperature Shall Be From -40°F To 150°F (-40°C To 65°C)
              • Sensor Shall Include Integral Temperature Sensor. Temperature Sensors Requiring Separate Mounting And Wire Runs Shall Not Be Accepted

                  Additional Information:
                  • Item Code: OCF-4
                  Yes! I am Interested
                  Get CALLBACK

                  Tuning Fork Level Switch

                  Tuning Fork Level Switch
                   
                  Ask For Price
                  Product Price:  Get Latest Price

                  Product Details:
                  Working PressureLess than 2 MPA
                  Density of MediumMin.05 g/cm3
                  Electrical ConnectionM 20 x 1.5
                  Wetted MaterialSS 304,SS 316 L,Coated with PTFE
                  Connection1" NPT (M)

                  We are offering our valuable clients a wide range of Tuning Fork Level Switch. Manufactured utilizing finest quality raw material and is precisely designed under the supervision of adroit professionals, we resourced this level switch from the authentic vendors of the industry. Our clients can avail this level switch in various specifications and can be customized as per their specific requirements at market leading price range.

                  Features:
                  • Complete electrical design circuit, without maintenance after operation
                  • without effect of foam powder
                  • special tuning fork design and its inherent vibration characteristic which ensure the function of automatic elimination and maximally prevent material hanging.

                  Applications:
                  • Liquids, solids, particles and power with good fluidity in various fields

                  Working Principle:
                  • The electric circuit signal energies the crystal in the fork which makes the probe of the tuning fork vibrate at a certain rate. When the probe is completely whelmed by the material measured, the vibration frequency of the fork will be changed, then the electric of the meter can automatically detect the difference and transfer it into switch will be output by the relay for on-spot alarming and remote control; when the material departs from the probe, the meter restores to the normal working condition to detect the changes of material level. 

                  Product Details:
                  ModelSD-YCO 1 SA-LM-200
                  SD-YC 71
                  (Explosion proof type)
                  Power Supply24 VAC/DC (Standard)
                  220 VAC, 110 VAC(Optional)
                  Contact Capacity220 VAC 5A, DPDT
                  Medium Temperature-10 °C~80°C (high temperature type:max 150° C)
                  Yes! I am Interested
                  Get CALLBACK

                  Bearing Tester

                  Bearing Tester
                   
                  Ask For Price
                  Product Price:  Get Latest Price

                  Product Details:
                  ApplicationIndustrial Use
                  Frequency50 Hz to 1,000 Hz
                  Vibration Limit50 g peak (100 g peak-peak)
                  Signal to Noise Ratio80 dB
                  Sensitivity100 mV g +/-10%

                  Backed by our flourishing business processes, we are able to trade and supply a flawless quality Bearing Tester. Our vendor’s experts design and manufacture this bearing tester using superior quality raw material and latest technology. In line up with the international quality standard, offered bearing tester is thoroughly tested in opposition to various quality parameters by our quality controllers. Moreover, offered bearing tester is used evaluating and checking condition of all types ball & roller bearings on site.

                  Features:

                  • Accuracy in result
                  • Robustness
                  • Optimum performance
                  Yes! I am Interested
                  Get CALLBACK

                  Digital Level Master

                  Digital Level Master
                   
                  Ask For Price
                  Product Price:  Get Latest Price

                  Product Details:
                  ApplicationLaboratory
                  Lowest Water Inactive Zone2.5'' floater-25 mm
                  Temperature-40 deg C~70 deg C
                  Probe Length600~4000 mm
                  Power Supply+24~26 V DC

                  We are listed amongst the renowned organizations in this domain, engaged in trading and supplying superior quality Digital Level Master. Our vendors’ skillful professionals design and manufacture this level master using higher grade factor inputs and latest techniques at their advanced manufacturing unit. Moreover, this level master is recognized for its working under inconsiderate conditions. Our clients can avail this level master from us in diverse specifications as per their requirements.

                  Features:
                  • Robust construction
                  • Fine finish
                  • Operational friendly
                  Yes! I am Interested
                  Get CALLBACK

                  Doppler Flow Meter 4.0

                  Doppler Flow Meter 4.0
                   
                  Ask For Price
                  Product Price:  Get Latest Price

                  Product Details:
                  BrandGreyline
                  SensorStrap-On, Single Head Ultrasonic For 1/2" to 180" (12.5 Mm to 4.5 M) Id Pipes
                  Sensor Cable20 Ft / 6 M Shielded Coaxial Pair
                  OutputIsolated 4-20 Ma (1000 Ohm)
                  Power Input100-130 VAC 50/60 Hz

                  Features:
                  • Installation: Sensor Compound Kit: Pc3 Stainless Steel Sensor Mounting Clamp
                  • Enclosure: Watertight Nema4X (Ip66) Polycarbonate
                  • Displays: Flow Rate: Large 4-Digit Lcd: Totalizer/Menu/Status: 16-Digit Alphanumeric
                  • Calibration: Built-In 3-Key Programmer
                  • Sensitivity: Keypad Adjustable
                  • Sensitivity: Keypad Adjustable
                  • 3 Control Relays: 5 Amp Spdt: Programmable For Flow Proportional Pulse Output, And/Or Flow Alarm
                  • Back flow Rejection: External, Voltage-Free Relay Input
                  • Electrical Surge Protection And Rfi Filters: Ac Line, Sensor, 4-20Ma
                  • 1 Manual: Installation And Operation

                  Doppler Flow Meter SpecificationsScope: 
                  • This Specification Covers A Non-Intrusive, Ultrasonic Doppler-Type Flow Meter As Manufactured By Grey line Instruments Inc., Massena, New York / Long Sault, Ontario. The Instrument Shall Provide For Velocity Or Volumetric Indicating And Transmitting Of The Flow Rate In A Full Pipe.

                  Performance Specifications:
                  • The Flow Meter Shall Operate With A Single-Head Flow Sensor Mounted Externally On Any Contiguous Pipe Material That Conducts Sound Including: Carbon Steel, Stainless Steel, Ductile Iron, Copper, Frp, Pvc, Abs, Or Cement Lined Pipe From 1/2" To 180" (12.5 Mm To 4.5 M) Id
                  • Measure And Indicate Flow Rates Between 0.2 To 40 Ft/Sec (0.06 To 12.2 M/Sec) With Accuracy Of ±2% Of Full Scale On Liquids With Entrained Particles Or Gases Of 100 Microns Or Larger And Minimum Concentrations Of 75 Ppm

                  Transducer (Flow Sensor):
                  • The Flow Sensor Shall Be Single-Head, Ultrasonic In A Stainless Steel Housing. It Shall Be Installed On The Outside Of A Pipe Without Interrupting Flow. The Sensor Shall Be Capable Of Continuous Operation At Temperatures From -40°F To 200°F (-40°C To 93°C), And To Withstand Accidental Submersion Pressures To 10 Psi. Manufacturers Recommended Coupling Compound And Stainless Steel Mounting Clamp Shall Be Included
                  • Shall Include 20 Ft (6M) Sensor Cable, Shielded Coaxial Pair
                  • Shall Be Capable Of Extending Sensor Cable Up To 500 Ft (152M) Without Requirement For Operator Adjustment
                  • Shall Be Transformer Isolated And Designed To Meet Intrinsic Safe Requirements. Shall Be Designed For Maximum Rfi Rejection, And Include Automatic High Voltage Bleeds For Nearby Lightning Strikes.

                  Additional Information:
                  • Item Code: DFM-40
                  Yes! I am Interested
                  Get CALLBACK

                  Vibration Meter

                  Vibration Meter
                   
                  Ask For Price
                  Product Price:  Get Latest Price

                  Product Details:
                  Usage/ApplicationIndustrial
                  WeightUpto 900 g
                  CommunicationUSB2.0 Full Speed
                  Operation Temperature-10 deg C~ 50 deg C
                  StorageRAM 64M & Flash 1GB

                  We have gained immense recognition in the industry by trading and supplying quality assured Vibration Meter. This vibration meter is designed and manufactured using elevated quality raw material and contemporary technology underneath the direction of our vendors’ adroit professionals. Offered vibration meter is rigorously tested on assured quality parameters to ensure its consistency. Furthermore, we offer our clients this vibration master at industry leading price range.

                  Features:
                  • Compact design
                  • High strength
                  • Low maintenance
                  Yes! I am Interested
                  Get CALLBACK

                  Level & Flow Monitor

                  Level & Flow Monitor
                   
                  Ask For Price
                  Product Price:  Get Latest Price

                  Product Details:
                  SensorPZ32T, PVC and teflon, 32 ft / 10 m range
                  OutputIsolated 4-20 mA (1000 ohm)
                  Sensor Cable25 ft / 7.6m coaxial
                  Power Input100-130 VAC 50/60 Hz, 7 watts maximum

                  We are a remarkable entity, engaged in trading and supplying a superior quality Level & Flow Monitor. This monitor is designed to deliver specific results as per the applications. Offered monitor is manufactured by our vendors experienced professionals utilizing optimum quality raw material and up to date technology in sync with the international standards. In addition, our clients can avail this monitor from us at the most competitive price range.

                  Features:
                  • Enclosure: watertight, dust tight NEMA4X (IP66) polycarbonate
                  • Programming: built-in 3 button keypad, Password protected
                  • Calibration: Level, Range or Open Channel Flow
                  • Displays: Level/Flow values: large 4-digit LCD Menu/Status/Totalizer: 16-digit alphanumeric
                  • 3 relays: 5 ampere SPDT, programmable alarm and/or pump control modes, lead/lag pump
                  • Temperature compensation: automatic
                  • Electrical surge protection: sensor, AC power and 4-20 mA output
                  • 1 PC software utilities disk
                  • 1 Manual: Installation and Operation

                  Level + Flow Monitor Specifications:Scope: 
                  • This specification covers a non-contacting ultrasonic Level/Flow Monitor as manufactured by Grey line Instruments, Massena New York / Long Sault, Ontario. This instrument shall provide for indicating, transmitting and control of the material level in a vessel or proximity of a target to the instrument sensor, and indicating, transmitting, and totalizing of the flow rate through a flume, weir, or other primary measuring device.

                  General:
                  • Level/Flow Monitor to consist of an non-contacting ultrasonic sensor, connecting cable, and a remote enclosure with indicating, transmitting and controlling electronics
                  • Measurement accuracy shall be ±0.25% of Range or 2 mm (0.08"), whichever is greater, and shall be automatically temperature compensated
                  • Sensor cable length shall be as required by installation, not to exceed 500' (152 m
                  • System shall have no moving parts and shall not contact the material being measured
                  • Shall include PC software program disk to determine open channel flow calibration values for non-standard flumes and weirs

                  Sensing Element:
                  • Sensor shall be constructed of PVC and Teflon
                  • The sensor shall have a minimum dead band or blanking of 12" (305 mm) and a maximum range of 32 ft.(10 m), and have an operating frequency of 42 kHz with an ultrasonic beam angle of 8 Degrees
                  • sensor shall withstand accidental submersion to 20 psi
                  • Sensor operating temperature shall be from -40°F to 150°F (-40°C to 65°C)
                  • Sensor shall include integral temperature sensor. Temperature sensors requiring separate mounting and wire runs shall not be accepted

                  Sensor Connecting Cable:
                  • Provide RG 62 AU coaxial cable 25' (7.6 m) continuous length, with waterproof, potted bond to the Sensor head
                  • Extended sensor cable shall be RG 62 AU coaxial to a maximum of 500' (152 m). Cable shall be spliced with screw terminal connections in manufacturer's recommended steel NEMA4 Junction Box
                  • Level and temperature signals shall be conducted on one single coaxial cable. Separate or multiple-conductor cables shall not be accepted
                  • Sensor cable shall be installed in grounded metal conduit

                    Additional Information:
                    • Item Code: SLT32
                    Yes! I am Interested
                    Get CALLBACK

                    Area Velocity Flow Monitor

                    Area Velocity Flow Monitor
                     
                    Ask For Price
                    Product Price:  Get Latest Price

                    Product Details:
                    BrandGreyline
                    Power Supply9-36 V DC
                    Measurement Range50~ 2000 mm
                    Flow Level4-20 mA Outputs

                    Owing to our expertise in this domain, we are engaged in trading and supplying an excellent quality Area Velocity Flow Monitor. Our vendors’ skillful professionals design and manufacture this flow meter utilizing finer quality factor inputs and cutting-edge technology. Also, offered flow meter finds various applications such as municipal storm water, stream flow, irrigation water, raw sewage, sluice ways, water intake channels, cooling water discharges and industrial effluent. We offer this flow meter at market-leading price range to our valuable clients.

                    Measures Velocity + Level to Monitor Flow with Multiple Ultrasonic Sensors:
                    • Monitor flow through large open channels, partially full sewer pipes and surcharged pipes without a flume or weir. Designed for municipal storm water, stream flow, irrigation water, raw sewage, sluice ways, water intake channels, cooling water discharges and industrial effluent.
                    • The AVMS 5.1 uses three submerged ultrasonic sensors to continuously measure both Velocity and Level in the channel. It is recommended for large channels or applications where velocity will vary across the width of the channel.
                    • The sensors resist fouling, corrosion and abrasion. The flow meter can be configured with three standard submerged velocity-level sensors, or with three submerged velocity plus a separate non-contacting ultrasonic level sensor.

                    Product Details:
                    • For Large Open Channels and Pipes (6 ft / 2 m or larger)
                    • Includes 3 Velocity Sensors for Average Velocity measurement
                    • Measures Forward and Reverse Flow
                    • 3 Isolated 4-20 mA Outputs (Flow, Level and Velocity)
                    • Totalizer and 2 Control Relays
                    • Simple 5-key Calibration
                    • Optional built-in 2-million point
                    • Data Logger and Software with USB output to Flash Drives

                    Additional Information:
                    • Item Code: AVMS-5-1
                    Yes! I am Interested
                    Get CALLBACK

                    Portable Doppler Flow Meter

                    Portable Doppler Flow Meter
                     
                    Ask For Price
                    Product Price:  Get Latest Price

                    Product Details:
                    DisplaysLarge 4-digit LCD - Totalizer/Menu/Status 16-digit alphanumeric
                    CalibrationBuilt-in 3-key programmer
                    Outputs4-20 mA, RS232C with programmable baud rates up to 19,200
                    Sensor Cable12ft / 3.5m shielded coaxial pair

                    Features:
                    • Sensor: Strap-on, single head ultrasonic for 1/2" - 180" (12.5 mm - 4.5 m) ID pipes
                    • Installation: Sensor coupling compound and stainless steel Sensor mounting clamp for 0.6 - 32 in. (15-800 mm) OD pipes
                    • Enclosure: Portable, aluminum (non-rated) in foam lined Cordura™ carry-case
                    • Sensitivity: Keypad adjustable
                    • Sensitivity: Keypad adjustable with signal strength indication
                    • Power input: Built-in battery with internal charger - switch select 100-160 VAC 50/60 Hz or 200-260 VAC 50/60 Hz - 12 VDC (from external battery)
                    • Data logger: 50,000 point with multi-session and flow report capability
                    • PC software for data log retrieval by direct serial connection, or by dial-up connection with modems and telephone lines
                    • 1 set cables and plugs - AC power, 4-20 mA, 12 VDC, RS232 1 Manual

                    Doppler Flow Meter Specifications:Scope: 
                    • This Specification Covers A Non-Intrusive, Ultrasonic Doppler-Type Flow Meter As Manufactured By Grey line Instruments Inc., Massena, New York / Long Sault, Ontario. The Instrument Shall Provide For Velocity Or Volumetric Indicating And Transmitting Of The Flow Rate In A Full Pipe.

                    Performance Specifications:
                    • The Flow Meter Shall Operate With A Single-Head Flow Sensor Mounted Externally On Any Contiguous Pipe Material That Conducts Sound Including: Carbon Steel, Stainless Steel, Ductile Iron, Copper, FRP, PVC, Abs, Or Cement Lined Pipe From 1/2" To 180" (12.5 Mm To 4.5 M) Id.
                    • Measure And Indicate Flow Rates Between 0.2 To 40 Ft/Sec (0.06 To 12.2 M/Sec) With Accuracy Of ±2% Of Full Scale On Liquids With Entrained Particles Or Gases Of 100 Microns Or Larger And Minimum Concentrations Of 75 P pm

                    Transducer (Flow Sensor):
                    • The Flow Sensor Shall Be Single-Head, Ultrasonic In A Stainless Steel Housing. It Shall Be Installed On The Outside Of A Pipe Without Interrupting Flow. The Sensor Shall Be Capable Of Continuous Operation At Temperatures From -40°F To 200°F (-40°C To 93°C), And To Withstand Accidental Submersion Pressures To 10 Psi. Manufacturer's Recommended Coupling Compound And Stainless Steel Mounting Clamp Shall Be Included
                    • Shall Include 20 Ft (6 M) Sensor Cable, Shielded Coaxial Pair
                    • Shall Be Capable Of Extending Sensor Cable Up To 500 Ft (152 M) Without Requirement For Operator Adjustment
                    • Shall Be Transformer Isolated And Designed To Meet Intrinsic Safe Requirements. Shall Be Designed For Maximum RFI Rejection, And Include Automatic High Voltage Bleeds For Nearby Lightning Strikes.

                      Additional Information:
                      • Item Code: PDFM-4
                      Yes! I am Interested
                      Get CALLBACK

                      Tank Farm Transmitter

                      Tank Farm Transmitter
                       
                      Ask For Price
                      Product Price:  Get Latest Price

                      Product Details:
                      OutputIsolated 4-20 Ma (1000 Ohm)
                      Sensor Cable25 ft / 7.6 M coaxial
                      Power Input100-130 VAC 50/60 Hz, 7 watts maximum
                      SensorPZ 32 T, PVC and Teflon, 32 ft / 10 m range

                      With our rich industry experience and knowledge, we are engaged in trading and supplying high quality Tank Farm Transmitter. Offered transmitter is designed and manufactured by our vendors utilizing quality approved raw material and advance technology in relevance to the industry standards. Also, our clients can avail this transmitter from us in certain specifications and can be customized as per their precise requirements.

                      Features:
                      • Enclosure: Watertight, dust tight NEMA 4 X (IP66) polycarbonate
                      • Programming: Built-in 3 button keypad, Password protected
                      • Calibration: Level, Range or Open Channel Flow
                      • Displays: Level/Flow values - large 4-digit LCD Menu/Status/Totalizer - 16-digit alphanumeric
                      • 3 relays: 5 ampere SPDT, programmable alarm and/or pump control modes, lead/lag pump
                      • Temperature compensation: Automatic
                      • Electrical surge protection: Sensor, AC power and 4-20mA output
                      • 1 PC software utilities disk
                      • 1 Manual: Installation and Operation

                          Additional Information:
                          • Item Code: TFT32
                          Yes! I am Interested
                          View PDF
                          Get CALLBACK

                          Fuel Oil Level Transmitter

                          Fuel Oil Level Transmitter
                           
                          Ask For Price
                          Product Price:  Get Latest Price

                          Product Details:
                          MaterialSS
                          Accuracy+/- 0.1%
                          Power Supply24 V DC
                          Range0-70380 mmH2O

                          With our rich industry experience and knowledge, we are engaged in trading and supplying high quality Fuel Oil Level Transmitter. Our vendors professional design and manufacture these transmitters utilizing exceptional quality raw material and modern technology. In addition, we offer this atta chakki in various specifications and can be customized according to the particular requirements of the clients.

                          Features:
                          • Superior performance
                          • Longer service life
                          • Durable finish
                          • User friendly

                          Applications:
                          • Diesel fuels
                          • Hydraulic oils
                          • Vegetable oils
                          • Chemical holding tanks
                          • MEK and other solvents
                          • Many other, non-conductive liquids
                          Yes! I am Interested
                          Get CALLBACK

                          Boot Level Switch

                          Boot Level Switch
                           
                          Ask For Price
                          Product Price:  Get Latest Price

                          Product Details:
                          Operating Temperature-40 deg C~+135 deg C
                          Contact CapacityAC 220 VA,DC 50 W
                          Medium DensityMore than 0.45 g/cm3
                          WeightUpto 500 gm

                          Fostered with immense years of industry experience and market understanding, we are trading and supplying an excellent quality Boot Level Switch. Offered level switches are designed and manufactured using premium quality raw material and advance techniques at our vendor’s hi-tech manufacturing unit. In addition, our clients can avail these level switches from us at industry leading price range.

                          Features:
                          • Sturdy structure
                          • Compact design
                          • Easy installation
                          • Durability
                          Yes! I am Interested
                          Get CALLBACK

                          Conductivity Point Level Switch

                          Conductivity Point Level Switch
                           
                          Ask For Price
                          Product Price:  Get Latest Price

                          Product Details:
                          Response Time0.5 Sec
                          Switch Status DisplayGreen LED shows Normal,Red LED shows alarm.
                          Ambient Temperature0 deg C to +60 deg C
                          Power Consumption1.9 VA

                          With our rich industry experience, we trade and supply a supreme quality range of Conductivity Point Level Switch. These switches are designed and manufactured utilizing finest quality raw material and latest techniques at our vendors end. Stringently tested on diverse parameters by quality controllers to make certain its dependability, we provide these switches to our esteemed clients in different specifications as per their requirements.

                          Product Details:
                          • No moving part, free of maintenance.
                          • No special cable required for signal transmission, Economical to install.
                          • Long cable connection permissible between probe and evaluation unit.
                          • AC on probes for prevention of electrolytic deterioration of electrodes.
                          • Low voltage on probe for operational safety.
                          • Variety of control functions and installation system available, beside single point switching.
                          • 1 Two point action for automatic pump control.
                          • 2 Two point independent switching.
                          • 3 Three point switching, two points with pump control logic and one independent point.
                          • 4 Four point switching having two-pump control logic.
                          • 5 Multichannel -4 point independent switching available for various process conditions
                          • Variety of probes available for various process conditions.

                          Technical Specifications (Standard):
                          Switching Unit:
                          • Housing: Aluminum, weather proof, powder coated. for back panel mounting /DIN Rail mounting
                          • Cable entry: - As per housing option.
                          • Mains Voltage: 230/110 V AC (+/-15%), 50 Hz or 24 V DC ,Or 65 to 265 V Ac
                          • Output: 1 / 2 sets of potential free c/o contacts rated at 10 amps, 250 V AC for non-inductive loads.
                          • Safety operation: Field selected switch over for min. or max. (FSL/FSH) switching points.
                          Yes! I am Interested
                          Get CALLBACK

                          Doppler Flow Switch

                          Doppler Flow Switch
                           
                          Ask For Price
                          Product Price:  Get Latest Price

                          Product Details:
                          Accuracy+/- 2% of Rate for velocities
                          Repeatability+/- 2%
                          Power Supply115/230 VAC or 24 VDC
                          OutputsForm C Relay, COM, NO, NC

                          Features:
                          • Easy Calibration
                          • Accurate and Repeatable
                          • 5 amp DPDT Control Relay
                          • Adjustable ON/OFF Set-Points
                          • Adjustable Time Delay
                          • Relay Status LED
                          • Intrinsic Safety Option

                          Doppler Flow Switch Specifications:
                          Scope:
                          • This Specification Covers A Non-Intrusive, Ultrasonic Doppler-Type Flow Switch As Manufactured By Grey line Instruments Inc., Massena, New York / Long Sault, Ontario. The Instrument Shall Provide For Flow Control At Adjustable Flow Velocities.

                          General:
                            Each Portable Transit Time Flow Meter Shall Have The Following Design Features And Engineering Specifications:

                              Performance Specifications:
                              • The Flow Switch Shall Operate With A Strap-On Flow Sensor Mounted Externally On Carbon Steel, Stainless Steel, Ductile Iron, Copper, FRP, PVC, Abs, Or Cement Lined Pipe, And On Liquids With Entrained Particles Or Gases Of 100 Microns Or Larger And Minimum Concentrations Of 75 Ppm
                              • The Control On And Off Set-Points Shall Be Independently Adjustable For Flow Rates Between 0.25 Ft/Sec (0.076 M/Sec) And 10 Ft/Sec (3 M/Sec), In Pipes 1/2" (12.5 Mm) Id Or Larger

                              Transducer (Sensing Element):
                              • The Flow Sensor Shall Be Single-Head, Ultrasonic In A Stainless Steel Housing. It Shall Be Installed On The Outside Of A Pipe Without Interrupting Flow. The Sensor Shall Be Capable Of Continuous Operation At Temperatures From -40°F To 200°F (-40°C To 93°C), And To Withstand Accidental Submersion Pressures To 10 Psi. Manufacturer Recommended Coupling Compound And Stainless Steel Pipe Clamp Shall Be Included
                              • Shall Include 20 Ft (6M) Shielded Coaxial Cable Pair With Waterproof, Potted Bond To The Sensor Head.
                              • Shall Be Capable Of Extending Sensor Cable Up To 500 Ft (152 M), Without Adjustment, And With No Reduction In Performance Or Signal Strength
                              • Shall Be Designed For Maximum RFI Rejection, And Include Automatic High Voltage Bleeds For Nearby Lightning Strikes

                                Additional Information:
                                • Item Code: DFS-II
                                Yes! I am Interested
                                Get CALLBACK

                                Hydrostatic Level Transmitter

                                Hydrostatic Level Transmitter
                                 
                                Ask For Price
                                Product Price:  Get Latest Price

                                Product Details:
                                Accuracy0.25%FS standard
                                ApplicationIndustrial
                                Power Supply10~30 VDC, 0.5 V
                                Range0~1 mH2O-200 mH2O

                                We are known as the reputed organization in this field of operation, engaged in trading and supplying excellent quality Hydrostatic Level Transmitter. This transmitter is designed and manufactured by our vendor’s dexterous professionals using excellent quality raw materials and ultra-modern technology in consequence to the set industry norms. Offered transmitter is obtainable in various specifications to carry out the specific requirements of the clients

                                Features:
                                • Precise dimensions
                                • Compact design
                                • Sturdy construction
                                • High strength
                                Yes! I am Interested
                                Get CALLBACK

                                RF Admittance Point Level Switch

                                RF Admittance Point Level Switch
                                 
                                Ask For Price
                                Product Price:  Get Latest Price

                                Product Details:
                                Switch Status DisplayGreen LED shows Normal, Red LED shows alarm, Yellow
                                Ambient Temperature0 deg C to +60 deg C
                                Power Consumption1.9 VA
                                Mains Voltage230/110 V AC (+/-15%), 50 Hz or 18-55 V DC or 65 to 265 V AC.

                                We are a distinguished trader and supplier of a wide range of RF Admittance Point Level Switch. Offered switches are designed and manufactured utilizing top quality raw material and latest technology at our vendors unit under the administration of skilled professionals. Thoroughly tested on varied parameters to find out its reliability, these switches are available at most competitive price range.

                                Features:
                                • High performance
                                • Less maintenance
                                • Energy efficiency
                                • Low running cost

                                The salient features of this level measuring instrument are as follow:

                                • Three Element Coat Guard Technology
                                • Can be configured either for High or Low Level point switching
                                • Ignores material build-up on the probe
                                • Suitable for the highly dusty environment
                                • High Reliability
                                • Fast and Easy Installation Simple Calibration
                                • Field selectable operation logic
                                • Provides economical solutions
                                • Various models not required

                                The specifications of these point level switch are as follow:
                                Switching Unit:
                                • Housing: Aluminum, weather proof, powder coated. Integral with The probe/ suitable for back panel mounting
                                • Output: 1/2 sets of potential free c/o contacts rated at 5 amps, 230 V AC for non-inductive loads
                                • Switching delay: Continuously adjustable From 1 to 20 sec. probe Free or probe covered (Optional)
                                • Safety operation: Field selected switch over for min. or max. (FSL/FSH) switching points
                                • LED shows power on condition

                                Coat Guard Sensing Probe:
                                • Mounting: Screwed 1 ½ BSP (standard) Or Flanged (optional)
                                • Sense rod: Stainless steel
                                • Shield: Stainless steel
                                • Insulation: PTFE (standard) other on request and as per application.
                                • Operating Temp: 100 deg for the integral switching vessel unit., 225° C for remote switching unit
                                Yes! I am Interested
                                Get CALLBACK

                                Radar Level Transmitter for Liquid Material

                                Radar Level Transmitter for Liquid Material
                                 
                                Ask For Price
                                Product Price:  Get Latest Price

                                Product Details:
                                ApplicationFood and Beverages Water / Wastewater Chemicals with vapors
                                Max Pressure5 bar (without De-coupler)
                                EnclosureAluminum or S.S-94 V
                                Ingress ProtectionNEMA4 (IP-65)Type 4/4X

                                We are a well-renowned trader and supplier of the best Radar Level Transmitter for Liquid Material. This transmitter is designed and manufactured using first-class factor inputs and up to date technology in adherence with the industrial quality standards by our vendors. Rigorously tested on dissimilar quality parameters to ensure its consistency, our clients can avail this transmitter from us in various specifications as per their requirements.

                                Features:
                                • Programmable and Self Adjusting Tracking Radar with Output 4-20 mA/ 20-4mA (Isolated on 4 Wire Model's only )
                                • Optional RS232 OR RS485 For communications with calibration diagnostics & data logging software
                                • PL Compatible (Modbus RTU) Three or four Wire Operation
                                • Also Available 2 wire with HART output.

                                Environmental:
                                • Temperature: -40to 140 F (-40 to 60 C)
                                • Approvals: FCC Part 15 - Low communication device
                                • Installation category: class II

                                Process:
                                • Temperature PP Rod: - 40 to 176 F (-40 to 80º )
                                • De-coupler & PTFE Rod - 40 to 350 F(-40 to 177º C)
                                • Material Dielectric: Er >2

                                  Yes! I am Interested
                                  Get CALLBACK

                                  TDR Level Transmitter

                                  TDR Level Transmitter
                                   
                                  Ask For Price
                                  Product Price:  Get Latest Price

                                  Product Details:
                                  Measuring Range30 m
                                  Output Signal4-20 mA
                                  Accuracy+/-3 mm
                                  Power Supply24 V DC/220 V AC

                                  We are an unparalleled name, engaged in trading and supplying a premium quality TDR Level Transmitter that is widely used in various industries like food processing, chemical, pharmaceutical, and many more. Offered transmitter is designed and manufactured using finer quality raw material, procured from the authentic vendors of the market. Also, we offer this transmitter to our precious client’s at most competitive price range.

                                  Features:
                                  • Precise size
                                  • High durability
                                  • Fine finish
                                  • Easy installation
                                  Yes! I am Interested