Call 08048600851 58% Response Rate

our range

Ultrasonic FlowMeters Level Industrial Instruments

We are a leading Wholesale Trader of kts 590 bosch, blue-point 1/2" driver impact socket set, portable doppler flow meter, transit time flow meter, portable transit time flow meter and ultrasonic level and flow monitor from Indore, India.
KTS 590 Bosch

KTS 590 Bosch

Price on Request
ColorGreen
Voltage8 VDC - 28 VDC
BrandBosch
Accuracy+-0.75 % of measured value, plus +-0.25 % of measuring range
ConnectivityUSB 2.0
Model Name/NumberKTS 590
Product ConditionNew
FrequencyUp to 5 MHz
Operating SystemWindows based Bosch ESI[tronic] 2.0
The sturdy new KTS equipment, KTS 560 and KTS 590, are based on the Bosch diagnostic application ESI[tronic] 2.0. Not only do they support all of today's relevant diagnosticprotocols, but also future protocols based on Ethernet.
Apart from vehicle diagnosis, voltage, resistance, and current can be measured easily and efficiently.
The KTS 590 is equipped with a two-channel oscilloscope, that provides visual indication and analyses of voltage and current over time.
KTS 590 and KTS 560 can be used to measure vehicle signals from sensors and actuators.
The device also has a powerful in-built Bluetooth@ hardware that enables wirelessconnection to any Windows-based PC.

KTS 590 ECU diagnosis and enhancedmeasurement technology(2-chan nel multimeter, 2-channel osci Iloscope)

View Complete details

get quote request a call back
Blue-Point 1/2" Driver Impact Socket Set

Blue-Point 1/2" Driver Impact Socket Set

Rs 3,500  / PieceGet Best Price
BrandBlue-Point
Model Name/NumberBLPATSIMM 1215
Usage/ApplicationAutomobile Industry
Socket TypeImpact Socket
Drive Size1/2 Inch
Blue-Point 1/2" Driver Impact Socket Set contains 14 pcs. of Impact socket 6-point and 1 pcs of Impact Extension Bar.

View Complete details

get quote request a call back
Portable Doppler Flow Meter

Portable Doppler Flow Meter

Price on Request

Product Brochure

DisplayWhite, backlit matrix - displays flow rate, totalizer, operating mode and calibration menu
Flow Rate Range+/- 0.1 to 40 ft/sec (+/- 0.03 to 12.2 m/sec) in most applications
Pipe SizeUltrasonic Sensor mounts on any pipe from 1/2'' to 180'' ID (12.5 mm to 4.5 m)
Power InputBuilt-in NiMH battery for up to 18 hours continuous operation External charger with 100-240VAC
Carry CaseRated IP67 with protective molded foam insert
Language SelectionEnglish,French,Spanish
SensitivityAdjustable cut-off,Damping adjustable
Outputs4-20mA (500 ohm) when AC powered USB for Data Log transfer by direct PC connection
Electronics Operating Temperature-10 deg to 140 deg F (-23 deg to 60 deg C)
Electronics EnclosurePortable,ABS enclosure
Description:
  • It's ideal for flow troubleshooting, balancing and checking performance of permanent flow meters. The new PDFM 5.1 is fast and easy to operate – you can mount the sensor on the outside of a pipe in less than a minute. Use the built-in keypad and calibration menu to set up the flowmeter for your application. The PDFM 5.1 works on any liquid containing bubbles or solids and is recommended for "difficult liquids" like wastewater, slurries, sludge, chemicals, viscous liquids and abrasives. Measures flow through most metal and plastic pipes including PVC, ductile iron, carbon steel and stainless steel.
  • The Greyline PDFM 5.1 is AC/DC powered with built-in NiMH batteries and external charger. With its 4-20mA output you can use the PDFM 5.1 as a spare transmitter in critical applications. For flow studies and troubleshooting use the built-in 300,000 point Data Logger. Retrieve data logs with 'Greyline Logger' software – included free with each PDFM 5.1. Connect the USB output directly to your PC or Laptop to download data logger files.
  • The PDFM 5.1 includes a non-intrusive Doppler ultrasonic sensor for pipes from 1/2" to 180" (12.5 mm to 4.5 m) diameter, a stainless steel sensor mounting bracket and clamps, coupling compound and AC charger with a rugged IP67 carry case. It operates up to 18 hours from internal batteries and recharges overnight.

Features:
  • Clamp-on Ultrasonic Transducer
  • Handheld Meter with large backlit LCD Display and Totalizer
  • Internal Battery and/or AC Powered
  • Built-in 5-Key Calibrator
  • 300,000 point Data Logger
  • USB Output and Windows software
  • 4-20mA Output
  • Rugged, watertight Carry Case

Portable Doppler Flow Meter Specifications:
  • Scope: This specification covers a portable, ultrasonic Doppler-type flow meter as manufactured by Greyline Instruments, Largo, Florida / Long Sault, Ontario. This instrument shall provide for non-intrusive flow measurement, indication, totalizing, transmitting and data logging of the flow rate in a full pipe.

General:
  • Each portable Doppler flow meter shall have the following design features and engineering specifications:

Performance Specifications:
  • Measure forward and reverse flow ± 0.1 to 40 ft/sec (± 0.03 to 12.2 m/sec).
  • Have an accuracy of ±2% of full scale on most wastewater applications. Have linearity of ±0.5% and repeatability of ±0.25%.
  • Operate on liquids with entrained particles or gases of 100 microns or larger and minimum concentrations of 75 ppm.
  • Operate from the outside of common pipe materials including: carbon steel, stainless steel, ductile iron, copper, PVC, FRP, ABS and other selected engineering materials.
  • Operate on AC/DC power.

Transducer:
  • Have a single-head, clamp-on transducer with twin piezo-electric ceramic transmit and receive crystals encapsulated in epoxy resin and a stainless steel housing.
  • The transducer shall be solid state and transformer isolated, and operate at 640KHz.
  • The transducer shall be waterproof and operate at temperatures from -40°F to 300°F (-40°C to 150°C), and withstand accidental submersion to 10 psi.
  • The transducer shall be designed to install on pipes with inside diameter ranging from 1/2" to 180" (12.5 mm to 4.5 m).
  • Have a 12 ft (3.6 m) long flexible, shielded coaxial pair cable extending from the transducer to the electronics.
  • Shall include Manufacturer's recommended sensor coupling compound and adjustable stainless steel sensor mounting clamp.


Additional Information:

  • Item Code: PDFM-5.1

View Complete details

get quote request a call back
Transit Time Flow Meter

Transit Time Flow Meter

Price on Request

Product Brochure

Operating Temperature-5 deg to 140 degF (-20 deg to 60 degC)
Accuracy+/-1% of reading from 1.5 to 40 ft/sec (0.5 to 12.0 m/sec) and +/-0.015 ft/sec (+/-0.0046 m/sec) for
Analog outputIsolated 4-20mA / 0-5V, 1000 ohm load maximum, programmable offset
Power Input100-240 V AC 50-60 Hz, 10 VA maximum,Optional 9-32VDC, 10 Watts maximum
Approximate Shipping Weight12 lbs. (5.5 kg)
ProgrammingBuilt-in 5-button keypad with English, French and Spanish menu language selection
ApprovalCE, CSA/UL/EN 61010-1
Electronics EnclosureWatertight and dust tight NEMA4X (IP 66) polycarbonate with clear, shatterproof cover
Operating ParametersFor clean liquids in full pipes with less than 2% solids or gas bubbles
Description:
  • Accurately measure the flow rate of relatively clean, non-aerated liquids like potable water, raw water, cooling water, de-ionized or reverse-osmosis water, oils and chemicals in full pipes. Ultrasonic transducers mount on the outside of a pipe without shutting down flow. Flow rate is displayed on the large, backlit display, along with total volume, signal strength, relay status, and other diagnostic values. Use the built-in control relays as flow alarms or volume totalization. Connect the isolated 4-20mA output to PLC's or controllers. A 128MB data logger is standard, capable of capturing up to 26 million data points. Optional MODBUS RTU via RS-485 available for connection to automation systems.
  • The TTFM 6.1 works on a wide range of pipe sizes and materials including carbon steel, stainless steel, ductile iron, concrete lined ductile iron, cast iron, PVC, PVDF, fiberglass, copper, brass, aluminum and pipes with bonded liners including epoxy, rubber and Teflon.
  • The TTFM 6.1 Transit Time Flow Meter operates by measuring the “transit time” or “time of flight” for ultrasonic sound pulses transmitted from one transducer to another. Depending on the mounting configuration, the signal may cross the pipe once, twice or four times. To measure flow the transit time is compared between ultrasonic signals travelling upstream and downstream.

TTFM 6.1 Standard Features Include:
  • Enhanced Performance
  • Wide Range of Applications
  • Easy to Install and Configure
  • Non-Contacting Clamp-on Ultrasonic Transducers
  • Works on a Large Variety of Pipe Materials and Sizes
  • Large Backlit Flow Rate Display and Totalizer
  • Isolated 4-20mA Output
  • 2 Programmable Control Relays
  • Optional MODBUS® RTU or HART Output
  • Application Optimization Available
  • 128MB Data Logger
  • Plug-and-play options including MODBUS RTU output and extra control relays
  • Programming built-in 5-button keypad

Specifications:Scope: 
  • This specification covers a Clamp-On Transit-Time Ultrasonic Flow Meter as manufactured by Greyline Instruments, Largo, Florida / Long Sault, Ontario. The meter shall provide for non-intrusive flow measurement, direction indication, volume totalizing, and transmitting of the flow rate in a full pipe.

Performance Specifications:
  • The ultrasonic flow meter shall have an accuracy of ±1% of reading or ±0.015 ft/sec (±0.0046 m/sec), whichever is greater. Have repeatability and linearity of ±0.25%.
  • Shall operate on relatively clean liquids in full pipes with less than 2% solids or gas bubbles at flow velocities from ±0.07 to 40 ft/sec (±0.02 to 12 m/sec).
  • Operate on any metal, or plastic, sonic conducting material including carbon steel, stainless steel, ductile iron, concrete lined ductile iron, cast iron, PVC, PVDF, fiberglass, galvanized steel, copper, brass and pipes with bonded liners including epoxy, rubber and Teflon.
  • The ultrasonic flow meter shall be optimized and pre-programmed for the application when information like pipe material, pipe size, wall thickness, fluid type, fluid temperature, and max flow rate are provided at time of order.

Transducers (Flow Sensors):
  • The flow meter shall have a dual transmitting/receiving, clamp-on transducers.
  • The transducers shall operate continuously at temperatures from -40°F to 300°F (-40°C to 150°C).
  • The standard transducer pair shall be designed to install on pipes with inside diameter ranging from 2" to 48" (50 mm to 1200 mm).
  • Have 25 ft (7.6 m) length triaxial cables from the electronics with BNC connectors to transducers.


      Additional Information:

      • Item Code: TTFM6.1

      View Complete details

      get quote request a call back
      • Portable Transit Time Flow Meter
      • Portable Transit Time Flow Meter
      • Portable Transit Time Flow Meter
      Portable Transit Time Flow Meter

      Portable Transit Time Flow Meter

      Price on Request

      Product Brochure

      Operating Temperature-5 deg to 140 deg F (-20 deg to 60 deg C)
      ApprovalsAC Charger is CE and UL approved
      Accuracy+/- 1% of reading or 0.1 ft/sec (0.03 m/sec), whichever is greater
      Outputs4-20mA (500 ohm) when powered by AC adapter
      Electronics EnclosurePortable, ABS
      Repeatability and Linearity+/- 0.25%
      Operating ParametersFor clean liquids in full pipes with less than 2% solids or gas bubbles
      Power InputBuilt-in NiMH battery for up to 18 hours continuous operation External charger with 100-240VAC
      Approximate Shipping Weight12 lbs. (5.5 kg)
      Description:
      • Recommended for fluids like water, glycol, oils and chemicals. Use it for calibrations, troubleshooting, flow surveys and as a temporary transmitter to replace inline flowmeters.
      • The PTFM 1.0 ultrasonic transducers clamp-on the outside of pipes from 2" to 48" (50 to 1200 mm) diameter. The ultrasonic signal works through common pipe materials including carbon steel, stainless steel, ductile iron, cast iron, PVC, PVDF, fiberglass, copper, brass, aluminum and pipes with bonded liners including epoxy, rubber and Teflon. Transducers can be mounted without shutting down flow and there is no obstruction or pressure drop. It measures and totalizes forward and reverse flow.
      • The PTFM 1.0 Portable Transit Time Flow Meter operates by measuring the “transit time” or “time of flight” for ultrasonic sound pulses transmitted from one transducer to another. Depending on the mounting configuration the signal may cross the pipe once, twice or four times. To measure flow the transit time is compared between ultrasonic signals travelling upstream and downstream.

      Features:
      • Non-Contacting Clamp-on Ultrasonic Transducers Works on Metal and Plastic Pipes
      • Large Backlit Flow Rate Display and Totalizer
      • Isolated 4-20mA Output
      • Built-in 5-Key Calibrator
      • 300,000 point data logger

      User-Friendly Operating System:
      • Calibration is easy with the onscreen menu system. Just enter the pipe diameter, wall thickness and pipe material. The PTFM 1.0 is powered by an internal, rechargeable NiMH battery or can be operated continuously with AC power adapter. Each PTFM 1.0 includes a watertight carry case, transducer set, cables and mounting clamps.

      Built-in Data Logger with Windows Software Included:
      • Set up the 300,000 point data logger to store time and date-stamped flow readings from 10 second to 5 minute intervals. View the convenient on-screen 'Flow Report' where total, minimum, maximum and average flow rates are stored in a 24 hour daily summary.
      • Transfer flow logs to your PC or laptop through the PTFM 1.0's USB output. Greyline Logger software (included) displays data in both graph and table formats with one-click export to Microsoft Excel®, images or CSV files for use in other programs.

      Portable Ultrasonic Flow Meter Specifications:Scope:
      • This specification covers a portable, ultrasonic Transit Time flow meter by Greyline Instruments, Largo, Florida / Long Sault, Ontario. This portable instrument shall provide for non-intrusive flow measurement, indication, totalizing and transmitting of the flow rate in a full pipe.

      General:
      • Each portable Transit Time flow meter shall have the following design features and engineering specifications:

      Performance Specifications:
      • The ultrasonic flow meter shall have an accuracy of ±1% of reading or 0.1 ft/sec (0.03 m/sec), whichever is greater. Have repeatability and linearity of ±0.25%.
      • Shall operate on clean liquids in full pipes with less than 2% solids or gas bubbles at flow velocities from ±0.07 to 39 ft/sec (±0.02 to 12 m/sec).
      • Operate on the following pipe materials: carbon steel, stainless steel, PVC, PVDF, fiberglass, galvanized steel, mild steel, ductile iron, glass, copper, brass and pipes with bonded liners including cement, epoxy, rubber and Teflon.
      • Operate on AC power or from internal, rechargeable batteries.

      Transducers:
      • The flow meter shall have a dual transmitting/receiving, clamp-on transducers operating at 1.28MHz.
      • The transducers shall operate continuously at temperatures from -40°F to 300°F (-40°C to 150°C).


      Additional Information:

      • Item Code: PTFM-1.0

      View Complete details

      get quote request a call back
      Ultrasonic Level and Flow Monitor

      Ultrasonic Level and Flow Monitor

      Price on Request

      Product Brochure

      DisplayWhite,backlit matrix displays flow rate,totalizer,relay status,operating mode and calibration menu
      Operating Temperature-5 deg to 140 deg F (-20 deg to 60 deg C)
      Accuracy+/-0.25% of Range or 2 mm (0.08'') whichever is greater, Repeatability and Linearity +/-0.1%
      OutputIsolated 4-20mA, 1000 ohm load maximum, programmable offset
      Electronics EnclosureWatertight and dust tight NEMA4X (IP 66) polycarbonate with clear, shatterproof cover
      Operating ModesLevel, Range or Open Channel Flow
      Power Input100-240VAC 50-60Hz (see Options), 2.4-5.6 Watts depending on options
      Electrical Surge ProtectionSensor, 4-20mA and AC power input
      Approximate Shipping Weight10 lbs. (4.5 kg)
      ProgrammingBuilt-in 5-key calibrator with English, French or Spanish language selection
      Description:
      • Use this versatile instrument to continuously measure, display, transmit and control liquid level in storage tanks and pumping stations, or to monitor and totalize Open Channel Flow through any flume or weir. Mount the non-contacting ultrasonic sensor above the liquid being measured and install the watertight electronics enclosure nearby. Features a user-friendly keypad calibration system, backlit LCD display, an isolated 4-20mA output and 2 programmable control relays.
      • Calibration is easy with the built-in 5 button keypad. The SLT 5.0 offers simple menu selection of measurement units (gallons, liters etc.), calculates volume in horizontal round tanks, or flow rate (and total) through any flume or weir.
      • For hazardous locations, the ultrasonic sensor is rated Intrinsically Safe with an optional safety barrier. The standard PVC and Teflon Sensor is rated for measurement ranges up to 32 ft/10 m, or select optional sensors for flange-mount or applications requiring longer measurement range. Options include 4 additional control relays (6 total) and a built-in 2-million point Data Logger with USB output to Flash memory sticks.

      Features:
      • Measure Level or Open Channel Flow
      • User-Friendly Calibration System
      • Isolated 4-20mA (1000 ohm)
      • False Echo Rejection
      • 2 Programmable Control Relays
      • Electrical Surge Protection
      • Intrinsically Safe Sensor Option
      • Plug and Play Relay and Data Logger Options

      Other Details:
      • Use it for Level: Specify SLT 5.0 for inventory monitoring and level control of chemicals, wastewater, viscous or corrosive liquids. Built-in control relays are programmable for pump control, pump alternation and level alarms. 
      • Use it for Flow: Displays, transmits and totalizes wastewater flow through any flume or weir. Features a simple, password protected calibration system, automatic totalizer and flow proportionate control relays. 
      • No maintenance Sensor: Each SLT 5.0 includes a non-contacting ultrasonic sensor which mounts above the material being measured. There is no contact and no moving parts. The sensor is sealed to withstand accidental submersion and rated for hazardous locations with optional intrinsic safety barrier.



      Additional Information:

      • Item Code: SLT-5.0

      View Complete details

      get quote request a call back
      AVFM 5.0 Area Velocity Flow Monitor

      AVFM 5.0 Area Velocity Flow Monitor

      Price on Request

      Product Brochure

      Channel TypesRound pipe, Rectangular, trapezoid, egg or custom shapes
      Electronics EnclosureWatertight and dust tight NEMA4X (IP 66) polycarbonate with clear, shatterproof cover
      Programmingbuilt-in 5-key calibrator with English, French or Spanish language selection
      Power Input100-240VAC 50-60Hz (see Options), 3.0-6.24 Watts depending on options
      AccuracyLevel +/-0.25% of Range. Velocity +/-2% of Reading. Repeatability and Linearity +/-0.1%
      DisplayWhite,backlit matrix displays flow rate, totalizer, relay states,operating mode and calibration menu
      Outputs3 Isolated 4-20mA, 1000 ohm, (Flow, Level and Velocity) or 0-5VDC by menu selection
      Electrical Surge ProtectionSensor, 4-20mA outputs and AC power input
      Operating Temperature-5 deg to 140 degF (-20 deg to 60 degC)
      Approximate Shipping Weight10 lbs. (4.5 kg)
      Description:
      • Monitor flow through open channels, partially full sewer pipes and surcharged pipes without a flume or weir. Ideal for stormwater, combined effluent, raw sewage, irrigation water and streams. Calibration is simple: enter the pipe diameter or channel shape and the AVFM 5.0 computes the flow volume and displays the flow rate. Measure forward and reverse flow and calibrate to channels of any shape.

      How It Works:
      • The AVFM 5.0 uses a submerged ultrasonic sensor to measure both Velocity and Level in the channel. The sensor is completely sealed with no orifices or ports. It mounts inside a pipe or at the bottom of a channel.

      Features:
      • For Open Channels and Pipes No Flume or Weir Required
      • Ultrasonic - Measures Velocity + Levelto Calculate Flow
      • Works in partially filled and surcharged pipes
      • 3 Isolated 4-20mA Outputs(Flow, Level and Velocity)
      • Isolated 4-20mA/0-5V Output
      • Totalizer and 2 Control Relays
      • Optional Intrinsically Safe Sensor
      • Optional built-in 2-million point Data Logger

      Other Details:
      • Area-Velocity Flow Meter: Monitor flow through open channels, partially full sewer pipes and surcharged pipes without a flume or weir. Ideal for municipal stormwater, combined effluent, raw sewage and irrigation water.
      • Submersible Ultrasonic Sensor: The AVFM 5.0 uses a submerged ultrasonic sensor to continuously measure both Velocity and Level in the channel. The sensor resists fouling, corrosion and abrasion. The flowmeter can be configured with the standard submerged velocity-level sensor, or with submerged velocity plus a separate non-contacting ultrasonic level sensor.
      • View flowrate and total flow on the large backlit LCD display and connect to external devices with three 4-20mA outputs and two control relays.


        Additional Information:

        • Item Code: AVFM-5.0

        View Complete details

        get quote request a call back
        Doppler Flow Meters

        Doppler Flow Meters

        Price on Request

        Product Brochure

        Accuracy+/- 2% of reading or 0.05 ft/sec (0.015 m/sec). Requires solids or bubbles minimum
        CalibrationBuilt-in 5-key calibrator with English,French or Spanish language selection
        OutputIsolated 4-20 mA (1000 ohm load max.)
        Flow Rate Range+/-0.1 +/-0.03 to 40 ft/sec ( to 12.2 m/sec) in most applications
        Data LoggerBuilt-in 2 million point logger with output and Windows software
        Pipe SizeAny pipe from 1/2'' to 180'' (12.7 mm to 4.5 m) ID
        Power Input9-32 V DC
        Control Relays4 additional (6 total) rated 5 ampere SPDT
        Enclosure HeaterFor outdoor installation,16 watt thermostatically controlled to -40 deg F (-40 deg C)
        Description:
        • Measure flow from outside a pipe. The Greyline DFM 5.1 is designed for "difficult liquids" that would damage regular flow meters - wastewater, slurries, sludge, chemicals, viscous liquids and abrasives. There is no obstruction to flow and no pressure drop. The non-intrusive, clamp-on ultrasonic sensor fits any pipe 1/2" (12.5 mm) Inside Diameter or larger. The electronics/display enclosure can be mounted nearby.
        • Use the isolated 4-20mA to transmit flow to remote displays, recorders or controllers. The programmable relays can be used for flow control, pump protection or flow proportionate pulse. Calibration is easy with the built-in 5-key calibrator. Display and totalize flow in your choice of engineering units (gallons, liters etc.)
        • Sensor cable can be extended up to 500 ft. (152 m) with no loss of signal. The standard sensor is rated non-incendive for Class I, Division 2 hazardous locations and the DFM 5.1 can be equipped with optional Intrinsic Safety Barriers for sensor installation in Class I, Division I hazardous locations. Other options include extra control relays and a built-in 2 million point Data Logger with USB output to Flash Drives.
        • The DFM 5.1 includes a new digital signal processor to filter background noise and interference, and to measure flow rates accurately in liquids containing gas bubbles or solids particles.


        Features:
        • Non-Contacting Ultrasonic Sensor
        • Accurate and Verifiable
        • Built-in 2-million point Data Logger and Windows Software
        • USB Outputs to Flash Memory Sticks
        • Simple 5-key Calibration with Language Selection
        • Isolated 4-20mA/0-5V Output
        • 2 Programmable Control Relays

        Doppler Flow Meter Specifications:
        • Scope: This specification covers a non-intrusive, ultrasonic Doppler-type flow meter as manufactured by Greyline Instruments Inc., Largo, Florida / Long Sault, Ontario. The instrument shall provide for velocity or volumetric indicating and transmitting of the flow rate in a full pipe.

        Performance Specifications:
        • The flow meter shall operate with a single-head flow sensor mounted externally on any contiguous pipe material that conducts sound including: carbon steel, stainless steel, ductile iron, copper, FRP, PVC, ABS, or cement lined pipe from 1/2" to 180" (12.5 mm to 4.5 m) ID.
        • Measure and indicate flow rates from +0.25 to +40 ft/sec and -0.25 to -40 ft/sec (+0.075 to +12.2 m/sec and -0.075 to -12.2 m/sec) with accuracy of ±2% of reading on liquids with entrained particles or gases of 100 microns or larger and minimum concentrations of 75 ppm.

        Transducer (Flow Sensor):
        • The flow sensor shall be single-head, ultrasonic in a stainless steel housing. It shall be installed on the outside of a pipe without interrupting flow. The sensor shall be capable of continuous operation at temperatures from -40°F to 300°F (-40°C to 150°C), and to withstand accidental submersion pressures to 10 psi. Manufacturer's recommended coupling compound and stainless steel mounting clamp shall be included.
        • Shall include 20 ft (6m) Sensor cable, shielded coaxial pair.
        • Shall be capable of extending sensor cable up to 500 ft (152m) without requirement for operator adjustment.
        • Shall be transformer isolated and designed to meet intrinsic safe requirements. Shall be designed for maximum RFI rejection, and include automatic high voltage bleeds for nearby lightning strikes.
        • Sensor shall be rated Non-incendive for Class I, Division 2, Groups A, B, C & D locations.


        Additional Information:

        • Item Code: DFM-5.1

        View Complete details

        get quote request a call back
        OCF 5.0 Open Channel Flow Monitor

        OCF 5.0 Open Channel Flow Monitor

        Price on Request

        Product Brochure

        DisplayWhite,backlit matrix displays flow rate,totalizer,relay status,operating mode and calibration menu
        Operating Temperature-5 deg to 140 deg F (-20 deg to 60 deg C)
        Accuracy+/-0.25% of Range or 2 mm (0.08'') whichever is greater, Repeatability and Linearity+/-0.1%
        OutputIsolated 4-20mA/0-5V, 1000 ohm load maximum, programmable offset
        Approximate Shipping Weight10 lbs (4.5 kg)
        ProgrammingBuilt-in 5-key calibrator with English, French or Spanish language selection
        Electronics EnclosureWatertight and dust tight NEMA4X (IP 66) polycarbonate with clear, shatterproof cover
        Power Input100-240VAC 50-60Hz (see Options), 2.95-5.6 Watts depending on options
        Electrical Surge ProtectionSensor, 4-20mA and AC power input
        Description:
        • Continuously monitor, display, totalize and data log flow through any flume or weir. The OCF 5.0 includes a non-contacting ultrasonic sensor that mounts just 8" (203.2 mm) above the flowing water. It is accurate (±0.25%) and reliable. There is no obstruction to flow and no fouling. Use the built-in Keypad/menu system to select your flume or weir from the Menu and to choose measurement units (gallons, liters etc.)
        • The Greyline OCF 5.0 includes built-in 2-million point Data Logger and flow reporting system. Connect a flash memory stick to the flowmeter's USB output to download log files and then view your data in graph and table formats with 'Greyline Logger' software – supplied free with each OCF 5.0. Daily flow reports including minimum, maximum, average and total daily flow can be viewed directly on the backlit OCF 5.0 LCD display. New! Logger Download to USB Flash Drive
        • Use the isolated 4-20mA to transmit flow to remote chart recorders or displays, and the control relays are programmable for level/flow alarm, and flow proportionate pulse (for samplers, chlorinators or remote totalizers). An Intrinsic Safety Barrier is optional for sensor and cable installation in hazardous rated locations. The separate, watertight electronics/display enclosure is mounted at a convenient location within 500 ft (150 m) of the sensor.

        Features:
        • Non-Contacting Ultrasonic Sensor
        • Large, Backlit LCD Display
        • 12-Digit Totalizer
        • Isolated 4-20mA (1000 ohm)
        • 2 Programmable Control Relays
        • Automatic Sensitivity Adjustment
        • Built-in 5-Key Calibrator
        • Optional 2 million point Data Logger with USB output to Flash memory

        Other Details:
        • Non-Contacting Sensor: The OCF 5.0 uses a non-contacting ultrasonic sensor mounted over a flume or weir to measure flow. It is accurate, reliable and verifiable. The separate, watertight electronics/display enclosure can be mounted within 500 ft (150 m) of the sensor. The OCF 5.0 continuously displays, totalizes, transmits and data logs open channel flow.
        • Keypad Operating System: Use the built-in keypad for fast, easy calibration with menu selection of flume or weir and measurement units (e.g. gallons, liters etc.) Calibration values and data logs are password-protected and retained during power interruptions. The OCF 5.0 will display on-screen flow reports with daily total, minimum, maximum and average flow and will transfer data logs to a USB flash drive. PC software is included.


          Additional Information:

          • Item Code: OCF-5

          View Complete details

          get quote request a call back
          Portaflow PT400 Portable Transit Time Flow Meter

          Portaflow PT400 Portable Transit Time Flow Meter

          Price on Request

          Product Brochure

          Accuracy+/-2% of reading in most applications
          Repeatability+/-0.5%
          Flow Rate Range0.65 to 40 ft/sec (0.2 to 12 m/sec)
          Pipe Wall Thickness0.039 - 2.95'' (1 - 75 mm)
          Outputs0/4-20mA, 5V pulse (1 pulse/sec maximum)
          Totalizer12 digits - displays separate forward and reverse flow totals
          Data LoggerNot available (see model PT500)
          Carry CasePolypropylene with protective molded foam insert
          Electronics EnclosureRated IP54, ABS portable
          Fluid ApplicationRecommended for clean liquids with less than 2% solids or gas bubbles
          Pipe Size'A' Transducers - 0.51'' to 4.5'' Outside Diameter (13 mm to 115 mm)
          Description:
          • Recommended for clean fluids like water, glycol, oil and most chemicals. Sensors can be mounted without shutting down flow and there is no obstruction or pressure drop. The ultrasonic signal travels through all common metal and plastic pipe materials. Flow rate and totalizer are displayed continuously along with battery status, signal strength. Press one key to instantly change the units of flow measurement (e.g. from gallons to liters). Real time flow can be displayed in large numeric values or as a graph.
          • Portaflow calibration is easy with the onscreen menu system. Enter the pipe diameter, wall thickness and pipe material, and the PT400 calculates the optimum mounting method and separation distance for the sensors.
          • The Portaflow PT400 ultrasonic sensors clamp on the outside of vertical or horizontal pipes. Select a Sensor pair for the range of pipe sizes you will monitor:

          Select a Sensor pair for the range of pipe sizes you will monitor:
          • Transducers for 0.51" to 4.5" Outside Diameter (13 to 115 mm) or Transducers for 2” to 39.37” Outside Diameter (50 to 1000 mm)
          • Calibration parameters can be stored for up to twenty different sites so that operators can recall calibration setups from the Portaflow memory. Use the 5V pulse or 4-20 mA output to transmit to external devices like data loggers or recorders. The P400 includes 'A' or 'B' sensor pairs, stainless steel guide rail and mounting clamps, sensor cables, coupling compound and AC charger with a rugged polypropylene carry case. It operates up to 16 hours from internal batteries and recharges overnight.

          Features:

          • Clamp-on Ultrasonic Sensors
          • Choose Small Pipe or Large Pipe Sensors
          • Internal Battery and/or AC Powered
          • Easy Calibration and Set-up
          • Flow Proportionate Pulse Output
          • 4-20 mA Output

          Portable Ultrasonic Flow Meter Specifications:Scope:
          • This specification covers a portable, ultrasonic Transit Time flow meter by Greyline Instruments, Largo, Florida / Long Sault, Ontario. This portable instrument shall provide for non-intrusive flow measurement, indication, totalizing and transmitting of the flow rate in a full pipe.

          General:
          • Each portable Transit Time flow meter shall have the following design features and engineering specifications:

          Performance Specifications:Have an accuracy of ±2% of reading in most clean fluid applications. Have repeatability of ±0.5%.
          • Operate on clean liquids in full pipes with less than 2% solids or gas bubbles.
          • Operate on any sonic conducting pipe material such as carbon steel, stainless steel, galvanized steel, mild steel, copper, UPVC, PVDF, glass, brass and including pipes with bonded liners of epoxy, rubber or cement.
          • Operate on AC/DC power. Include an internal NiMH rechargeable battery with capacity for 16 hours continuous battery operation. Recharge and operate with power input of 100-260VAC 50-60Hz.
          • Ultrasonic Transducers:
          • Have a dual 2 MHz transmitting/receiving, clamp-on transducers.
          • The transducers shall be waterproof and operate continuously at temperatures from -4°F to 275°F (-20°C to 135°C).
          • The transducers shall be designed to install on pipes with inside diameter ranging from 0.51" to 4.5" OD (13 mm to 115 mm).
          • Have a 6 ft (2 m) long cable from the transducers to the electronics.
          • Shall include manufacturer's recommended sensor coupling compound.
          • Shall include stainless steel sensor mounting guiderails with clamps permitting installation and removal of transducers.
          • Shall include a transducer test block to allow the transducers and inter-connecting cables to be functionally checked.


          Additional Information:

          • Item Code: PT400

          View Complete details

          get quote request a call back
          Transit Time Flow Meter for Clean Liquid

          Transit Time Flow Meter for Clean Liquid

          Price on Request
          DisplayWhite, back light matrix
          BrandGreyline
          Totalizer14 digits
          CalibrationBuilt-in 5-key programmer
          OutputIsolated 4-20 mA (1000 ohm)
          Transit Time Flow Meter for Clean Liquid Accurately measure the flow rate of clean, non-aerated liquids like water, chemicals, and oils in full pipes. Ultrasonic transducers mount on the outside of a pipe without shutting down flow. Flow rate is displayed on the large, back light display along with totalizer and signal strength. Use the built-in control relays for flow alarms or flow proportionate pulse. Connect the isolated 4-20 mA output to PLC's or controllers. The TTFM 1.0 works on a wide range of pipe sizes and materials including carbon steel, stainless steel, ductile iron, cast iron, PVC, PVDF, fiberglass, copper, brass, aluminum and pipes with bonded liners including epoxy, rubber and Teflon. The TTFM 1.0 Transit Time Flow meter operates by measuring the “transit time” or “time of flight” for ultrasonic sound pulses transmitted from one transducer to another. Depending on the mounting configuration, the signal may cross the pipe once, twice or four times. To measure flow the transit time is compared between ultrasonic signals traveling upstream and downstream.

          Features:
          • Non-Contacting Clamp-on Ultrasonic Transducers
          • Works on Metal and Plastic Pipes
          • Large Back light Flow Rate Display and Totalizer
          • Isolated 4-20 mA Output
          • Built-in 5-Key Calibrator
          • 2 Programmable Control Relays
          • Optional 20 Million Point Data Logger

          Product Details:
          • pair SE16B ultrasonic transducers - clamp-on for 1/2” to 48” (12 mm to 1200 mm) pipes and rated nonincendive for Class I, Division 2, Groups A, B, C & D locations
          • Sensor cables - pair 25 ft / 7.6 m coaxial with BNC connectors
          • Flow rate range: ± 0.07 to 39 ft/sec (± 0.02 to 12 m/sec)
          • Installation - stainless steel transducer mounting brackets and clamps, alignment bar and silicone coupling compound kit
          • Enclosure - watertight, NEMA4X (IP66) polyester and polycarbonate
          • 2 control relays - 5 amp, SPDT - programmable for flow proportional pulse output, and/or flow alarm
          • Plug-and-play options including data logger and extra control relays
          • Electrical surge protection and RFI filters - AC, sensor, 4-20 mA


          Additional Information:

          • Item Code: TTFM-1

          View Complete details

          get quote request a call back
          Area Velocity Flow Monitor

          Area Velocity Flow Monitor

          Price on Request
          BrandGreyline
          Sensor Cable25 ft / 7.6 m submersible, shielded 3-coaxial
          EnclosureWwatertight, NEMA4X (IP66) polycarbonate
          Power Input100-160 VAC 50/60 Hz
          Electrical Surge Protection and RFI FiltersAC, sensor, 4-20 mA
          DisplaysFlow Rate Large 4-digit LCD - Totalizer/Menu/Status - 16-digit alphanumeric
          As a well-known trader and supplier in this domain, we are offering high quality Area Velocity Flow Monitor. Flow monitor offered by us is designed and manufactured by our vendors utilizing optimum quality raw material and latest technology. Rigorously tested on quality parameters to ensure its flawlessness, this flow monitor is obtainable in various specifications at most competitive price range.

          Features:
          • QZ02L sensor: Measures flow Velocity and Level
          • Calibration: Built-in 3-key programmer
          • Output: Three isolated 4-20mA (1000 ohm), Flow, Level and Velocity
          • 2 control relays: 5 amp, SPDT - programmable for flow proportional pulse output, flow and/or level alarm
          • 1 Manual: Installation and Operation

          Area-Velocity Flow Monitor Specifications:Scope:
          • This Specification Covers An Ultrasonic, Area-Velocity Flow Monitor As Manufactured By Grey line Instruments, Massena, New York / Long Sault, Ontario. The Instrument Shall Provide For Indicating, Transmitting, Totalizing Of The Flow Rate Through Partially Filled Or Surcharged Round Pipes Or Rectangular, Trapezoidal And Egg-Shaped Channels.

          General:
          • Flow Monitor To Consist Of A Submersible Ultrasonic Sensor, Connecting Cable, And Remote Enclosure With Indicating, Transmitting And Controlling Electronics. System Shall Have No Moving Parts
          • Level Measurement Accuracy Shall Be ±0.25% Of Range. Velocity Measurement Accuracy Shall Be ±2% Of Reading

          Sensing Element:
          • Ultrasonic Sensor Shall Be Designed For Continuous Submersion In Liquids
          • Using The Doppler Principle, The Sensor Shall Measure Fluid Velocities From 0.1 To 20 Ft/Sec (0.03 To 6.2 M/Sec)
          • Using Ultrasonic Echo-Ranging Principle, The Submerged Sensor Shall Measure Liquid Level From 1" To 15 Ft. (25.4 Mm To 4.57 M). Minimum Level Shall Not Be Greater Than 1" (25.4 Mm). Level Sensing Circuitry Shall Include A Temperature Sensor For Automatic Temperature Compensation
          • Sensor Shall Be Constructed Of Pvc And Epoxy Resin
          • Sensor Operating Temperature Shall Be 5°F To 150°F (-15°C To 65°C)


          Additional Information:

          • Item Code: AVFM-II

          View Complete details

          get quote request a call back
          Open Channel Flow Monitor

          Open Channel Flow Monitor

          Price on Request
          BrandGreyline
          Time DelayAdjustable, 0-60 seconds
          Power Input120 VAC 50/60 Hz
          EnclosureWatertight NEMA4X (IP 67) polycarbonate
          Sensor Cable20ft (6 m) shielded coaxial pair
          Features:
          • Sensor: Strap-on, single head ultrasonic
          • Installation: Sensor compound kit and stainless steel pipe clamp
          • 1 relay: 5 amp DPDT
          • Set point: ON/OFF adjustment 0.25 to 10 ft/sec (0.076 to 3 m/sec)
          • Failsafe mode: Switch selectable
          • Indication: Relays and signal strength LED's
          • Sensitivity: Adjustable
          • Electrical surge protection
          • 1 manual: Installation and Operation

          Open Channel Flow Monitor Specifications:Scope: 
          • This Specification Covers An Ultrasonic, Echo-Ranging Type Open Channel Flow Meter As Manufactured By Grey line Instruments, Massena, New York / Long Sault, Ontario. This Instrument Shall Provide For Indicating, Transmitting, Totalizing And Data Logging Of The Flow Rate Through A Flume, Weir, Or Other Primary Measuring Device.

          General:
          • Flow Monitor To Consist Of An Non-Contacting Ultrasonic Sensor, Connecting Cable, And A Remote Enclosure With Indicating, Transmitting, Controlling And Data Logging Electronics
          • Measurement Accuracy Shall Be ±0.25% And Shall Be Automatically Temperature Compensated
          • Sensor Cable Length Shall Be As Required By Installation, Not To Exceed 500 Ft (152 M)
          • System Shall Have No Moving Parts And Shall Not Contact Flowing Water

          Sensing Element:
          • Sensor Shall Withstand Accidental Submersion To 20 Psi
          • Sensor Minimum Range Shall Be 8" (203.2 Mm) And Maximum Range Shall Be 15 Ft (4.57 M)
          • Sensor Shall Be Constructed Of Pvc
          • Sensor Operating Temperature Shall Be From -40°F To 150°F (-40°C To 65°C)
          • Sensor Shall Include Integral Temperature Sensor. Temperature Sensors Requiring Separate Mounting And Wire Runs Shall Not Be Accepted


              Additional Information:

              • Item Code: OCF-4

              View Complete details

              get quote request a call back
              Doppler Flow Meter

              Doppler Flow Meter

              Price on Request
              BrandGreyline
              SensorStrap-On,Single Head Ultrasonic For 1/2" to 180" (12.5 Mm to 4.5 M) Id Pipes
              Sensor Cable20 Ft / 6 M Shielded Coaxial Pair
              OutputIsolated 4-20 Ma (1000 Ohm)
              Power Input100-130 VAC 50/60 Hz
              Features:
              • Installation: Sensor Compound Kit: Pc3 Stainless Steel Sensor Mounting Clamp
              • Enclosure: Watertight Nema4X (Ip66) Polycarbonate
              • Displays: Flow Rate: Large 4-Digit Lcd: Totalizer/Menu/Status: 16-Digit Alphanumeric
              • Calibration: Built-In 3-Key Programmer
              • Sensitivity: Keypad Adjustable
              • Sensitivity: Keypad Adjustable
              • 3 Control Relays: 5 Amp Spdt: Programmable For Flow Proportional Pulse Output, And/Or Flow Alarm
              • Back flow Rejection: External, Voltage-Free Relay Input
              • Electrical Surge Protection And Rfi Filters: Ac Line, Sensor, 4-20Ma
              • 1 Manual: Installation And Operation

              Doppler Flow Meter SpecificationsScope: 
              • This Specification Covers A Non-Intrusive, Ultrasonic Doppler-Type Flow Meter As Manufactured By Grey line Instruments Inc., Massena, New York / Long Sault, Ontario. The Instrument Shall Provide For Velocity Or Volumetric Indicating And Transmitting Of The Flow Rate In A Full Pipe.

              Performance Specifications:
              • The Flow Meter Shall Operate With A Single-Head Flow Sensor Mounted Externally On Any Contiguous Pipe Material That Conducts Sound Including: Carbon Steel, Stainless Steel, Ductile Iron, Copper, Frp, Pvc, Abs, Or Cement Lined Pipe From 1/2" To 180" (12.5 Mm To 4.5 M) Id
              • Measure And Indicate Flow Rates Between 0.2 To 40 Ft/Sec (0.06 To 12.2 M/Sec) With Accuracy Of ±2% Of Full Scale On Liquids With Entrained Particles Or Gases Of 100 Microns Or Larger And Minimum Concentrations Of 75 Ppm

              Transducer (Flow Sensor):
              • The Flow Sensor Shall Be Single-Head, Ultrasonic In A Stainless Steel Housing. It Shall Be Installed On The Outside Of A Pipe Without Interrupting Flow. The Sensor Shall Be Capable Of Continuous Operation At Temperatures From -40°F To 200°F (-40°C To 93°C), And To Withstand Accidental Submersion Pressures To 10 Psi. Manufacturers Recommended Coupling Compound And Stainless Steel Mounting Clamp Shall Be Included
              • Shall Include 20 Ft (6M) Sensor Cable, Shielded Coaxial Pair
              • Shall Be Capable Of Extending Sensor Cable Up To 500 Ft (152M) Without Requirement For Operator Adjustment
              • Shall Be Transformer Isolated And Designed To Meet Intrinsic Safe Requirements. Shall Be Designed For Maximum Rfi Rejection, And Include Automatic High Voltage Bleeds For Nearby Lightning Strikes.


              Additional Information:

              • Item Code: DFM-40

              View Complete details

              get quote request a call back
              KTS 560 Bosch

              KTS 560 Bosch

              Price on Request
              Voltage8 VDC - 28 VDC
              BrandBosch
              Accuracy+-0.75 % of measured value,plus +-0.25 % of measuring range
              ConnectivityUSB 2.0
              Model Name/NumberKTS 560
              Product ConditionNew
              The sturdy new KTS equipment, KTS 560 and KTS 590, are based on the Bosch diagnostic application ESI[tronic] 2.0. Not only do they support all of today's relevant diagnosticprotocols, but also future protocols based on Ethernet.
              Apart from vehicle diagnosis, voltage, resistance, and current can be measured easily and efficiently.
              The KTS 590 is equipped with a two-channel oscilloscope, that provides visual indication and analyses of voltage and current over time.
              KTS 590 and KTS 560 can be used to measure vehicle signals from sensors and actuators.
              The device also has a powerful in-built Bluetooth@ hardware that enables wirelessconnection to any Windows-based PC.

              KTS 590 ECU diagnosis and measurement technology(1-chan nel multimeter)

              View Complete details

              get quote request a call back
              Level & Flow Monitor

              Level & Flow Monitor

              Price on Request
              SensorPZ32T, PVC and teflon, 32 ft / 10 m range
              OutputIsolated 4-20 mA (1000 ohm)
              Power Input100-130 VAC 50/60 Hz, 7 watts maximum
              Sensor Cable25 ft / 7.6m coaxial
              We are a remarkable entity, engaged in trading and supplying a superior quality Level & Flow Monitor. This monitor is designed to deliver specific results as per the applications. Offered monitor is manufactured by our vendors experienced professionals utilizing optimum quality raw material and up to date technology in sync with the international standards. In addition, our clients can avail this monitor from us at the most competitive price range.

              Features:
              • Enclosure: watertight, dust tight NEMA4X (IP66) polycarbonate
              • Programming: built-in 3 button keypad, Password protected
              • Calibration: Level, Range or Open Channel Flow
              • Displays: Level/Flow values: large 4-digit LCD Menu/Status/Totalizer: 16-digit alphanumeric
              • 3 relays: 5 ampere SPDT, programmable alarm and/or pump control modes, lead/lag pump
              • Temperature compensation: automatic
              • Electrical surge protection: sensor, AC power and 4-20 mA output
              • 1 PC software utilities disk
              • 1 Manual: Installation and Operation

              Level + Flow Monitor Specifications:Scope: 
              • This specification covers a non-contacting ultrasonic Level/Flow Monitor as manufactured by Grey line Instruments, Massena New York / Long Sault, Ontario. This instrument shall provide for indicating, transmitting and control of the material level in a vessel or proximity of a target to the instrument sensor, and indicating, transmitting, and totalizing of the flow rate through a flume, weir, or other primary measuring device.

              General:
              • Level/Flow Monitor to consist of an non-contacting ultrasonic sensor, connecting cable, and a remote enclosure with indicating, transmitting and controlling electronics
              • Measurement accuracy shall be ±0.25% of Range or 2 mm (0.08"), whichever is greater, and shall be automatically temperature compensated
              • Sensor cable length shall be as required by installation, not to exceed 500' (152 m
              • System shall have no moving parts and shall not contact the material being measured
              • Shall include PC software program disk to determine open channel flow calibration values for non-standard flumes and weirs

              Sensing Element:
              • Sensor shall be constructed of PVC and Teflon
              • The sensor shall have a minimum dead band or blanking of 12" (305 mm) and a maximum range of 32 ft.(10 m), and have an operating frequency of 42 kHz with an ultrasonic beam angle of 8 Degrees
              • sensor shall withstand accidental submersion to 20 psi
              • Sensor operating temperature shall be from -40°F to 150°F (-40°C to 65°C)
              • Sensor shall include integral temperature sensor. Temperature sensors requiring separate mounting and wire runs shall not be accepted

              Sensor Connecting Cable:
              • Provide RG 62 AU coaxial cable 25' (7.6 m) continuous length, with waterproof, potted bond to the Sensor head
              • Extended sensor cable shall be RG 62 AU coaxial to a maximum of 500' (152 m). Cable shall be spliced with screw terminal connections in manufacturer's recommended steel NEMA4 Junction Box
              • Level and temperature signals shall be conducted on one single coaxial cable. Separate or multiple-conductor cables shall not be accepted
              • Sensor cable shall be installed in grounded metal conduit


                Additional Information:

                • Item Code: SLT32

                View Complete details

                get quote request a call back
                Area Velocity Flow Monitor

                Area Velocity Flow Monitor

                Price on Request
                BrandGreyline
                Power Supply9-36 V DC
                Measurement Range50~ 2000 mm
                Flow Level4-20 mA Outputs
                Owing to our expertise in this domain, we are engaged in trading and supplying an excellent quality Area Velocity Flow Monitor. Our vendors’ skillful professionals design and manufacture this flow meter utilizing finer quality factor inputs and cutting-edge technology. Also, offered flow meter finds various applications such as municipal storm water, stream flow, irrigation water, raw sewage, sluice ways, water intake channels, cooling water discharges and industrial effluent. We offer this flow meter at market-leading price range to our valuable clients.

                Measures Velocity + Level to Monitor Flow with Multiple Ultrasonic Sensors:
                • Monitor flow through large open channels, partially full sewer pipes and surcharged pipes without a flume or weir. Designed for municipal storm water, stream flow, irrigation water, raw sewage, sluice ways, water intake channels, cooling water discharges and industrial effluent.
                • The AVMS 5.1 uses three submerged ultrasonic sensors to continuously measure both Velocity and Level in the channel. It is recommended for large channels or applications where velocity will vary across the width of the channel.
                • The sensors resist fouling, corrosion and abrasion. The flow meter can be configured with three standard submerged velocity-level sensors, or with three submerged velocity plus a separate non-contacting ultrasonic level sensor.

                Product Details:
                • For Large Open Channels and Pipes (6 ft / 2 m or larger)
                • Includes 3 Velocity Sensors for Average Velocity measurement
                • Measures Forward and Reverse Flow
                • 3 Isolated 4-20 mA Outputs (Flow, Level and Velocity)
                • Totalizer and 2 Control Relays
                • Simple 5-key Calibration
                • Optional built-in 2-million point
                • Data Logger and Software with USB output to Flash Drives


                Additional Information:

                • Item Code: AVMS-5-1

                View Complete details

                get quote request a call back
                Portable Doppler Flow Meter

                Portable Doppler Flow Meter

                Price on Request
                CalibrationBuilt-in 3-key programmer
                Outputs4-20 mA,RS232C with programmable baud rates up to 19,200
                Sensor Cable12ft / 3.5m shielded coaxial pair
                DisplaysLarge 4-digit LCD - Totalizer/Menu/Status 16-digit alphanumeric
                Features:
                • Sensor: Strap-on, single head ultrasonic for 1/2" - 180" (12.5 mm - 4.5 m) ID pipes
                • Installation: Sensor coupling compound and stainless steel Sensor mounting clamp for 0.6 - 32 in. (15-800 mm) OD pipes
                • Enclosure: Portable, aluminum (non-rated) in foam lined Cordura™ carry-case
                • Sensitivity: Keypad adjustable
                • Sensitivity: Keypad adjustable with signal strength indication
                • Power input: Built-in battery with internal charger - switch select 100-160 VAC 50/60 Hz or 200-260 VAC 50/60 Hz - 12 VDC (from external battery)
                • Data logger: 50,000 point with multi-session and flow report capability
                • PC software for data log retrieval by direct serial connection, or by dial-up connection with modems and telephone lines
                • 1 set cables and plugs - AC power, 4-20 mA, 12 VDC, RS232 1 Manual

                Doppler Flow Meter Specifications:Scope: 
                • This Specification Covers A Non-Intrusive, Ultrasonic Doppler-Type Flow Meter As Manufactured By Grey line Instruments Inc., Massena, New York / Long Sault, Ontario. The Instrument Shall Provide For Velocity Or Volumetric Indicating And Transmitting Of The Flow Rate In A Full Pipe.

                Performance Specifications:
                • The Flow Meter Shall Operate With A Single-Head Flow Sensor Mounted Externally On Any Contiguous Pipe Material That Conducts Sound Including: Carbon Steel, Stainless Steel, Ductile Iron, Copper, FRP, PVC, Abs, Or Cement Lined Pipe From 1/2" To 180" (12.5 Mm To 4.5 M) Id.
                • Measure And Indicate Flow Rates Between 0.2 To 40 Ft/Sec (0.06 To 12.2 M/Sec) With Accuracy Of ±2% Of Full Scale On Liquids With Entrained Particles Or Gases Of 100 Microns Or Larger And Minimum Concentrations Of 75 P pm

                Transducer (Flow Sensor):
                • The Flow Sensor Shall Be Single-Head, Ultrasonic In A Stainless Steel Housing. It Shall Be Installed On The Outside Of A Pipe Without Interrupting Flow. The Sensor Shall Be Capable Of Continuous Operation At Temperatures From -40°F To 200°F (-40°C To 93°C), And To Withstand Accidental Submersion Pressures To 10 Psi. Manufacturer's Recommended Coupling Compound And Stainless Steel Mounting Clamp Shall Be Included
                • Shall Include 20 Ft (6 M) Sensor Cable, Shielded Coaxial Pair
                • Shall Be Capable Of Extending Sensor Cable Up To 500 Ft (152 M) Without Requirement For Operator Adjustment
                • Shall Be Transformer Isolated And Designed To Meet Intrinsic Safe Requirements. Shall Be Designed For Maximum RFI Rejection, And Include Automatic High Voltage Bleeds For Nearby Lightning Strikes.


                  Additional Information:

                  • Item Code: PDFM-4

                  View Complete details

                  get quote request a call back
                  Blue-Point Tools Trolley

                  Blue-Point Tools Trolley

                  Rs 12,500  / PieceGet Best Price
                  BrandBlue-Point
                  MaterialMild Steel
                  ColorBlue
                  Number Of Drawers5
                  Load Capacity45 Kg
                  Weight65 Kg
                  • High grade steel plate with PE Powder painting for better flowingproperty to avoid peel• Fully-openable drawers can withstand up to 45 kg weight• Bigger sized with greater capacity at 508 kg• Tubular lock-stronger over molded key lock• Ribs added for enhanced strength to prevent cabinet deformation

                  View Complete details

                  get quote request a call back
                  Level Indicating Transmitter

                  Level Indicating Transmitter

                  Price on Request

                  Product Brochure

                  Accuracy+/-0.25% of Range or 2 mm (0.08''), whichever is greater
                  OutputIsolated 4-20mA, 1000 ohm load maximum
                  Approximate Shipping Weight6 lbs. (2.7 kg)
                  Power Input100-130VAC 50/60Hz, 5 watts maximum
                  Operating Temperature-13 to 140 deg F (-25 to 60 deg C) (electronics)
                  DisplayLarge (3/4 in, 19 mm high) 4 digit LCD
                  Electronics EnclosureWatertight, dust tight NEMA4X (IP 66) polycarbonate with clear, shatterproof cover
                  Electrical Surge ProtectionSensor, 4-20mA and AC power input
                  CalibrationSelectable Level or Range mode. Enter min. and max. distance in inches or cm
                  Description:
                  • This new Greyline Transmitter displays, controls and transmits level. Mount the non-contacting ultrasonic sensor at the top of your tank and the compact, watertight electronics/display enclosure at a convenient location nearby. Operators can calibrate the LIT25 with its 2-button Keypad, without climbing the tank. Use the built-in relay for level control or alarm, the large 4-digit display for local indication, and the isolated 4-20mA output to to transmit level to a PLC.
                  • The standard ultrasonic Sensor measures liquid levels up to 32 ft. (10 m), and includes automatic temperature compensation. Choose the optional all-Teflon sensor for chemical compatibility, or one rated to 50 ft (15.6 m) range. All ultrasonic sensors are available with optional intrinsic safety for installation in hazardous rated locations. The LIT25 can also be ordered with gauge-type pressure sensors for special applications.

                  Features:
                  • Simple Calibration with 2-button keypad
                  • Large 4-digit LCD display
                  • Non-Contacting, no maintenance sensor
                  • Isolated 4-20mA output (1000 ohm)
                  • Relay for alarm or control
                  • Automatic temperature compensation
                  • Watertight, dust tight enclosure
                  • Low Cost – High accuracy (±0.25%)

                  Other Details:
                  • Transmits: The LIT25 Level Indicating Transmitter features a 4-20mA output rated up to 1000 ohms. This output is isolated and ready for direct connection to your PLC or Controller.
                  • Displays: Mount the watertight display enclosure at a convenient location where the large, 4-digit LCD Display is visible to Operators. Use the built-in Keypad for calibration without climbing the Tank.
                  • Controls: Use the LIT25 signal Relay output to control pumps and alarms. Calibrate for level, echo loss or temperature alarm.



                  Additional Information:

                  • Item Code: LIT25

                  View Complete details

                  get quote request a call back
                  MantaRay Portable Area Velocity Flow Meter

                  MantaRay Portable Area Velocity Flow Meter

                  Price on Request

                  Product Brochure

                  Operating Temperature-5 deg to 140 deg F (-20 deg to 60 degC)
                  AccuracyLevel+/-0.25% of Range or 1 mm (0.04''). Velocity+/-2% of Reading Repeatability and Linearity+/-0.1%
                  Battery Charger6A (100W Max), 100-240VAC 50/60Hz input, UL and CE listed
                  DisplayWhite,backlit matrix-displays flow rate,totalizer,relay states, operating mode and calibration menu
                  ProgrammingBuilt-in 5-key calibrator with English, French or Spanish language selection
                  Approximate Shipping Weight15 lbs. (6.8 kg)
                  Electronics EnclosureWatertight, airtight, dust proof (IP 67) polycarbonate
                  Channel TypesRound pipe, Rectangular, trapezoid, egg or custom shapes
                  Breakout BoxConnections for charger input, external battery input, 2 relays, 4-20mA (0-5V)
                  BatteryInternal rechargeable NiMH, 12VDC, 10,000 mAh
                  Logger IntervalsProgrammable 10, 30 sec, 1, 2, 5, 10, 15, 30, 60 min
                  Description:
                  • The MantaRay Portable Area-Velocity Flow Meter measures flow in open channels, partially filled and surcharged pipes using an ultrasonic sensor. It's designed for monitoring stormwater, sewage, industrial effluent, irrigation water and natural streams. The MantaRay displays and datalogs flow rate and total flow and connects to samplers, SCADA and telemetry systems.
                  • Calibration is simple: enter the pipe diameter or channel dimensions and the MantaRay automatically computes and displays the flow rate and total on its backlit LCD display. Mount the sensor at the bottom of the pipe or channel and hang the IP67 electronics case above the high water level.

                  Hydrodynamic Ultrasonic Sensor:
                  • The MantaRay uses a submerged ultrasonic sensor to continuously measure flow or reverse flow in open channels, partially filled or surcharged pipes. The sensor is a completely sealed ultrasonic unit with no orifices or ports. It is hydrodynamically shaped and designed to shed deposits and stringers for reliable operation in sewage, stormwater and stream flow applications.
                  • The QZ02L sensor mounts inside the pipe or at the bottom of an open channel. No special compounds, tools or hardware are required. A stainless steel mounting bracket is included and a size range of optional pipe bands are available for sensor installation in manholes.

                  Features:
                  • Measures flow in partially filled pipes and open channels
                  • No flume or weir required
                  • 4-20mA and Relay outputs for connection to Samplers and SCADA
                  • Powered with built-in rechargeable NiMH batteries
                  • 2 million point data logger with USB output to Flash drives
                  • Backlit LCD display for flow rate, totalizer and menu system

                  Other Details:
                  • Portable Open Channel Flow Meter: Designed for flow surveys in open channels, partially full sewer pipes and surcharged pipes. MantaRay is ideal for stormwater, sewage, irrigation water and natural streams. 
                  • Hydrodynamic Ultrasonic Sensor: The MantaRay uses a submerged ultrasonic sensor to continuously measure both Velocity and Level in the channel. The sensor resists fouling, corrosion and abrasion. View realtime flowrate and total flow on the large backlit LCD display. Connect to samplers or SCADA and telemetry systems with the 4-20mA and relay outputs. Download flow log files to a USB memory stick.


                  Additional Information:

                  • Item Code: MantaRay

                  View Complete details

                  get quote request a call back
                  Stingray 2.0 Portable Level-Velocity Logger

                  Stingray 2.0 Portable Level-Velocity Logger

                  Price on Request

                  Product Brochure

                  DisplayLCD displays Level, Velocity, Water Temperature, Battery and Memory capacity
                  AccuracyLevel +/-0.25% of Range, Velocity +/-2% of Reading
                  Instrument Set upvia Greyline Logger software for Windows Logging Time Interval, Site Name
                  USB Cable3 1 shielded ft ( m)
                  Approximate Shipping Weight10 lbs. (4.5 kg)
                  Output CommunicationsUSB
                  Data Logger Capacity130,000 data points
                  Power4 Alkaline 'D' cell batteries
                  Operating Temperature Range-4 deg to 140 deg F (-20 deg to 60 deg C)
                  Electronics EnclosureWatertight, airtight, dust proof ( 67) polycarbonate IP
                  Description:
                  • Stingray 2.0 measures evel and elocity in open channels or pipes. No calibration is required. The sensor l v is a completely sealed ultrasonic unit with no orifices or ports. It mounts inside the pipe or at the bottom of a channel. The watertight electronics enclosure is hung in the manhole or at a convenient location. Sensor, mounting bracket, batteries, software and cables are included with each Stingray.
                  • Compact and Portable: Stingray 2.0 is a compact, battery-powered logger with an ultrasonic sensor. It data logs level, velocity and water temperature readings for flow monitoring through open channels, partially full sewer pipes and surcharged pipes. Use it for flow surveys, I & I studies, stormwater, irrigation water and sewage.
                  • Hydrodynamic Ultrasonic Sensor: Stingray 2.0 uses a submerged ultrasonic sensor to continuously measure both velocity and level in the channel. The sensor is a completely sealed ultrasonic unit with no orifices or ports. It is hydrodynamically shaped and designed to shed deposits and stringers for reliable operation in sewage, stormwater and stream flow applications. The QZ02L sensor mounts inside the pipe or at the bottom of an open channel. No special compounds, tools or hardware are required. A stainless steel mounting bracket is included.
                  • Powered by Standard Alkaline Batteries: With 4 standard Alkaline D-cell batteries the Stingray 2.0 will operate up to 4 years! These inexpensive Alkaline batteries are available in stores everywhere and with an extremely low self discharge rate they will reliably power the energy-efficient Stingray 2.0 for the duration of your flow study.
                  • Stingray 2.0 stores 130,000 data points including level, velocity and water temperature. Between readings it powers down to conserve energy.
                  • Stingray 2.0 Confidence Display: You can check operation with the built-in LCD bar graph display. It scrolls through level, velocity and temperature readings, plus remaining battery and logger storage capacity. The display turns off automatically after 60 seconds to conserve battery power.

                  Features:
                  • Logs Level and Velocity
                  • for Flow Studies
                  • Includes powerful
                  • Windows software for
                  • Flow analysis and reporting



                    Additional Information:

                    • Item Code: Stingray2.0

                    View Complete details

                    get quote request a call back
                    • PSL 5.0 Hybrid Pump Station Level Controller
                    • PSL 5.0 Hybrid Pump Station Level Controller
                    PSL 5.0 Hybrid Pump Station Level Controller

                    PSL 5.0 Hybrid Pump Station Level Controller

                    Price on Request

                    Product Brochure

                    DisplayWhite, backlit matrix - displays calibration menu, relay status, runtime reports and sensor status
                    Operating TemperatureElectronics -5 to 140 deg F (-20 to 60 deg C)
                    Accuracy+/-0.25% of Range or 2 mm (0.08'') whichever is greater
                    CalibrationLevel or Range mode in selectable units
                    Surge ProtectionAC power, 4-20mA and ultrasonic sensor
                    Power Input100-240VAC 50-60Hz (see Options), 3 Watts maximum (with standard features)
                    OutputsIsolated 4-20mA (1000 ohm)
                    Electronics EnclosureWatertight, dust tight NEMA4X (IP 66) polycarbonate with a clear, shatter-proof face
                    ProgrammingBuilt-in, 5-button keypad, password-protected
                    Description:
                    • Ideal for Level Control: Designed for pump stations, wet wells and tank level control the new Greyline PSL 5.0 Pump Station Level Controller has six independently programmable control relays for pump or valve control, level alarms, autodialers, temperature or fault alarms.
                    • No contact, No maintenance: Mount the non-contacting, ultrasonic sensor in the tank or wet well and install the watertight electronics in the control room or any location within 500 ft / 150 m. Use the simple menu system and built-in keypad to set up measurement range, relay set points and pump alternation sequence. A relay/pump run time report is updated and stored automatically for viewing on the instrument’s backlit LCD display
                    • New Dual-Technology Sensor Feature Redundant Level Sensing: Connect a submersible pressure sensor or other 4-20mA level transmitter
                    • to the PSL 5.0 for fail-safe hybrid sensing. The PSL 5.0 will auto-calibrate the redundant sensor and if signal is lost to the ultrasonic sensor, the redundant sensor will seamlessly take over monitoring until signal resumes from the ultrasonic. The redundant sensor is continuously monitored to ensure availability during primary sensor failure.

                    Features:
                    • Non-Contacting Ultrasonic Sensor
                    • Accepts Pressure Sensor Input for Redundant Monitoring
                    • 6 Control Relays with Programmable Pump Alternation
                    • Automatically Logs and Reports Relay Run Times for Pump
                    • Performance Evaluation
                    • Plug and Play Optional Data Logger
                    • Isolated 4-20mA Output



                    Additional Information:

                    • Item Code: PSL-5.0

                    View Complete details

                    get quote request a call back
                    DLT 2.0 Differential Level Transmitter

                    DLT 2.0 Differential Level Transmitter

                    Price on Request

                    Product Brochure

                    Accuracy+/-0.25% of Range or 2 mm (0.08'') whichever is greater, Repeatability and Linearity+/-0.1%
                    Operating Temperature-5 deg to 140 deg F (-20 deg to 60 deg C)
                    Approximate Shipping Weight15 lbs. (6.8 kg)
                    Electrical Surge ProtectionSensor, 4-20mA outputs and AC power input
                    ProgrammingBuilt-in 5-key calibrator with English, French or Spanish language selection
                    Power Input100-240VAC 50-60Hz (see Options), 3 Watts maximum (with standard features)
                    Electronics EnclosureWatertight and dust tight NEMA4X (IP 66) polycarbonate with clear, shatterproof cover
                    Description:
                    • Reduce costs and simplify instrumentation at treatment plant headworks. The DLT 2.0 can measure both differential level plus flow through a flume. Install one Sensor on each side of a mechanical barscreen to continuously monitor, transmit and control level. Use the built-in control relays or 4-20mA outputs to automatically activate the barscreen rake at preset levels.
                    • The DLT 2.0 is a simple solution for barscreen level control at wastewater treatment plants, pump stations and combined sewer systems. It includes two non-contacting ultrasonic sensors to measure level. With sensors positioned above a channel, up and downstream from the barscreen, the DLT 2.0 can display and transmit differential level. The downstream sensor can also be installed above a flume or weir to measure and totalize open channel flow.
                    • Three 4-20mA outputs are configured to transmit upstream level, downstream level (or flow) and differential level. Built-in relays can be calibrated for level control, differential level control or open channel flow.
                    • Other DLT 2.0 applications include two-tank inventory where you can monitor level in two tanks with one instrument. The DLT 2.0 will alternate display of level in both tanks plus transmit 4-20mA outputs. Use the built-in relays to activate alarms or level controls. This versatile dual-sensor instrument can also be configured as a submergence alarm for Parshall flumes.

                    Features:
                    • Measures Level, Differential Level and Open Channel Flow
                    • Two Non-Contacting Ultrasonic Sensors
                    • Large White Backlit LCD Display
                    • Three Isolated 4-20mA Outputs
                    • Built-in 5-Key Calibration
                    • 2 Programmable Control Relays
                    • Optional 2 Million Point Data Logger
                    • Optional Intrinsically Safe Sensors

                    Other Details:
                    • Versatile, Easy to Use: Install one Sensor on each side of a barscreen to continuously monitor, transmit and control level. Use the built-in control relays or 4-20mA outputs to automatically activate the barscreen rake at preset levels.
                    • One Instrument Does the Work of Three: The DLT 2.0 is a simple solution for barscreen level control at wastewater treatment plant headworks, pump stations and combined sewer systems. It includes two non-contacting ultrasonic sensors to measure level. With sensors positioned above a channel, up and downstream from the barscreen, the DLT 2.0 can display and transmit differential level. The downstream sensor can also be installed above a flume or weir to measure and totalize open channel flow.
                    • Three 4-20mA outputs are configured to transmit upstream level, downstream level (or flow) and differential level. Built-in relays can be calibrated for level control, differential level control or open channel flow.



                      Additional Information:

                      • Item Code: DLT-2.0

                      View Complete details

                      get quote request a call back
                      • DFS 5.1 Doppler Flow Switch
                      • DFS 5.1 Doppler Flow Switch
                      DFS 5.1 Doppler Flow Switch

                      DFS 5.1 Doppler Flow Switch

                      Price on Request

                      Product Brochure

                      Power Input100-240 V AC 50-60 Hz (+/-10%), 2 Watts
                      Control Relay5 ampere DPDT
                      Set PointsON/OFF adjustment from 0.25 to 10 ft/sec (0.075 to 3 m/sec)
                      Shipping Weight8 lbs (3.6 kg)
                      EnclosureWatertight, dust tight NEMA4X (IP 67) polycarbonate with a clear shatter-proof face
                      SensorSingle-head ultrasonic with 20 ft (6m) shielded cable
                      Pipe SizeAny pipe ID from 1/2'' to 180'' (12.5 mm to 4.5 m)
                      Sensor Operating Temperature-40 deg to 300 deg F (-40 deg to 150 deg C)
                      Electronics Operating Temperature-10 deg to 140 deg F (-23 deg to 60 deg C)
                      Accuracy+/-2%, requires solids or bubbles minim
                      Description:Flow Switch With Non-Contacting Sensor:
                      • Control Flow from outside a pipe. Recommended for "difficult liquids" including wastewater, cooling water, slurries, sludge, chemicals, viscous liquids and abrasives. The Greyline DFS 5.1 is ideal for pump protection or to activate flow/no-flow alarms.

                      Easy to Calibrate:
                      • The DFS 5.1 control relay can be set to turn ON and OFF at any flow rate between 0.25 and 10 ft/sec (0.075 to 3 m/sec). Insert two links for separate ON/OFF set points or just one link for a Hi or Lo flow alarm. Set the relay actuation time delay from 0 to 80 seconds.
                      • A bright LED indicator shows the relay state and a LED bargraph shows the flow rate. Electronics are housed in a watertight polycarbonate wall-mount enclosure.
                      • The clamp-on ultrasonic sensor mounts on the outside of metal or platic pipes without cutting the pipe or shutting down flow. It works on any pipe diameter 1/2" (12.5 mm) or larger and installs in minutes. There are no moving parts and no maintenance is required. The shielded sensor cable length is 20 ft. (6 m) and can be extended up to 500 ft. (152 m) with an optional Junction Box.

                      Doppler Flow Switch Specifications:Scope:
                      • This specification covers a non-intrusive, ultrasonic Doppler-type flow switch as manufactured by Greyline Instruments Inc., Largo, Florida / Long Sault, Ontario. The instrument shall provide for flow control at adjustable flow velocities.

                      Performance Specifications:
                      • The flow switch shall operate with a clamp-on ultrasonic sensor mounted externally on any contiguous pipe material that conducts sound including: carbon steel, stainless steel, ductile iron, copper, FRP, PVC, ABS, or cement lined pipe from 1/2" to 180" (12.5 mm to 4.5 m) diameter.
                      • Shall operate on liquids with entrained particles or gases of 100 microns or larger and minimum concentrations of 75 ppm.
                      • The control ON and OFF set-points shall be independently adjustable for flow rates between 0.25 ft/sec (0.076 m/sec) and 10 ft/sec (3 m/sec).

                      Transducer (Sensing Element):
                      • The flow sensor shall be single-head, ultrasonic in a stainless steel housing. It shall be installed on the outside of a pipe without interrupting flow. The sensor shall be capable of continuous operation at temperatures from -40°F to 300°F (-40°C to 150°C), and to withstand accidental submersion pressures to 10 psi.
                      • Manufacturer's recommended coupling compound and stainless steel pipe clamp shall be included.
                      • Shall connect to separate electronics housing with 20 ft (6m) shielded coaxial cable pair with waterproof, potted bond to the Sensor head.
                      • Shall be capable of extending sensor cable up to 500 ft (152m) without adjustment and with no reduction in performance or signal strength.

                      Electronics/Controller:
                      • Shall be housed in a wall-mount watertight, dust tight NEMA4X (IP 66) polycarbonate enclosure with a gasketed shatter proof window.
                      • Have a power input of 100–240VAC 50-60Hz (±10%), 2.0 W Max.
                      • Shall include one 5 ampere DPDT control relay.
                      • Shall operate in Hi or Lo alarm mode, or with separate ON/OFF set points individually adjustable between 0.25 and 10 ft/sec (0.076 to 3 m/sec).
                      • The controller shall include an indicator LED to display relay status and a LED bargraph to display flow rate.
                      • The controller shall include relay time delay adjustment from 0 to 80 seconds.
                      • The flow switch electronics/controller shall operate at temperatures from -10° to 140°F (-23° to 60°C).
                      • Shall be designed for maximum RFI rejection.


                      Additional Information:

                      • Item Code: DFS-5.1

                      View Complete details

                      get quote request a call back
                      BAT 131 Bosch Battery Tester

                      BAT 131 Bosch Battery Tester

                      Price on Request
                      Operating Temperature0 deg C - 40 deg C
                      Cca Test Range100-2000A
                      Battery Nominal Voltage6V/12V
                      DimensionsApprox. 270 x 113 x 50 mm
                      BrandBosch
                      ModelBAT 131
                      ApplicationPassenger CarsC/ Commercial vehicles/SUVs/ Motorcycles
                      WeightApprox. 700 g
                      Battery TypesStandard,AGM (flat & spiral), Gel
                      Starting Charging Test System12V/24V
                      Description:
                      • The new portable battery tester – BAT 131 from Bosch is perfectly suitable for testing 6V and 12V starter batteries (lead-acid, gel and fleece batteries/AGM). The load-free test procedure provides fast, precise and reliable measurement results. The battery tester has a specially designed robust housing considering workshop requirements. The enhanced user interface enables simple and intuitive operation.

                      Features:
                      • Load free test for 6V and 12V lead acid batteries
                      • Test Range 100-2000 CCA
                      • Display wrong polarity messages
                      • Menu-guided intuitive operation, with results on large LCD screen
                      • Stores up to 100 test reports in easily understandable excel format
                      • USB port for report downloads and future software updates
                      • 3M replaceable cable for flexible diagnosis
                      • Testing possible in new/un-used/in-stock batteries
                      • Starter and Alternator test
                      • Integrated printer with latest feature for print option
                       
                      Benefits:
                      • Easy-to-use robust housing; fast and accurate test results
                      • Wide range of vehicle applications and testing norms
                      • Maintain history of service records for future follow-up with customers
                      • Various menu languages, “easy-to-understand” printouts for end customers
                      • Updating of software is possible with USB port


                      Additional Information:

                      • Item Code: BAT131

                      View Complete details

                      get quote request a call back
                      Pump Station Level Controller

                      Pump Station Level Controller

                      Price on Request
                      BrandGreyline
                      DisplaysLevel large 4-digit LCD; Menu/Reports/Status 16-digit alphanumeric
                      SensorPZ 34, PVC, 32 ft / 10 m range
                      Sensor Cable25ft / 7.6m coaxial
                      Power Input100-130 VAC 50/60 Hz, 8 watts maximum
                      Our immense domain expertise and market knowledge assist us to trade and supply the finest quality Pump Station Level Controller. Our vendors’ experts design and manufacture this level controller utilizing higher quality raw material at par with industry standards. The manufacturing process of this level controller is vigilantly examined at each step to ensure its dependability. Also, offered level controller is available in various specifications to our precious clients as per their precise requirement.

                      Features:
                      • Temperature compensation: Automatic
                      • Enclosure: Watertight, dust tight NEMA 4 X (IP 66) polycarbonate
                      • Programming: Built-in 3 button keypad, Password protected and "PSL Remote" Windows software
                      • Calibration: Level or Range mode in selectable units
                      • 6 relays: 5 ampere SPDT, programmable alarm and/or pump control modes, pump alternation/sequencing, failsafe/echo-loss, sensor temperature alarm
                      • Outputs: Isolated 4-20 mA (1000 ohm), RS232
                      • Report logger: Pump Run Time report
                      • Electrical surge protection: Sensor, AC power, 4-20 mA and RS 232 outputs
                      • 1 PC software: "PSL Remote" for Windows™ - calibrate and save as disk file, real-time PSL monitoring by RS 232 or modem connection
                      • 1 Manual: Installation and Operation

                      Pump Station Level Controller Specifications:Scope:
                      • This specification covers a non-contacting ultrasonic Pump Station Level Controller as manufactured by Grey line Instruments, Massena New York / Long Sault, Ontario. This instrument shall provide for indicating, transmitting of wet well or tank level, and control of up to six pumps or alarms.

                      General:
                      • Pump Station Level Controller to consist of an non-contacting ultrasonic sensor, connecting cable, and a remote enclosure with indicating, transmitting and controlling electronics
                      • Measurement accuracy shall be ±0.25% of Range or 2 mm (0.08"), whichever is greater, and shall be automatically temperature compensated
                      • Sensor cable length shall be as required by installation, not to exceed 500' (152 m)
                      • System shall have no moving parts and shall not contact the material being measured
                      • Shall include a built-in keypad and simple menu system for calibration, and Windows™ software for calibration and monitoring by modems or direct RS232 connection

                      Sensing Element:
                      • Sensor shall be constructed of PVC
                      • The sensor shall have a minimum dead band or blanking of 16" (407 mm) and a maximum range of 32 ft. (10 m), and have an operating frequency of 46 kHz with an ultrasonic beam angle of 8 Degrees
                      • Sensor shall withstand accidental submersion to 20 psi
                      • Sensor operating temperature shall be from -40°F to 150°F (-40°C to 65°C)
                      • Sensor shall include integral temperature sensor. Temperature sensors requiring separate mounting and wire runs shall not be accepted

                      Sensor Connecting Cable:
                      • Provide RG 62 AU coaxial cable 25' (7.6 m) continuous length, with waterproof, potted bond to the Sensor head
                      • Extended sensor cable shall be RG 62 AU coaxial to a maximum of 500' (152 m). Cable shall be spliced with screw terminal connections in manufacturer's recommended steel NEMA 4 Junction Box
                      • Level and temperature signals shall be conducted on one single coaxial cable. Separate or multiple-conductor cables shall not be accepted
                      • Sensor cable shall be installed in grounded metal conduit


                      Additional Information:

                      • Item Code: PSL

                      View Complete details

                      get quote request a call back
                      Tuning Fork Level Switch

                      Tuning Fork Level Switch

                      Price on Request
                      Working PressureLess than 2 MPA
                      Density of MediumMin.05 g/cm3
                      Wetted MaterialSS 304,SS 316 L,Coated with PTFE
                      Electrical ConnectionM 20 x 1.5
                      Connection1" NPT (M)
                      We are offering our valuable clients a wide range of Tuning Fork Level Switch. Manufactured utilizing finest quality raw material and is precisely designed under the supervision of adroit professionals, we resourced this level switch from the authentic vendors of the industry. Our clients can avail this level switch in various specifications and can be customized as per their specific requirements at market leading price range.

                      Features:
                      • Complete electrical design circuit, without maintenance after operation
                      • without effect of foam powder
                      • special tuning fork design and its inherent vibration characteristic which ensure the function of automatic elimination and maximally prevent material hanging.

                      Applications:
                      • Liquids, solids, particles and power with good fluidity in various fields

                      Working Principle:
                      • The electric circuit signal energies the crystal in the fork which makes the probe of the tuning fork vibrate at a certain rate. When the probe is completely whelmed by the material measured, the vibration frequency of the fork will be changed, then the electric of the meter can automatically detect the difference and transfer it into switch will be output by the relay for on-spot alarming and remote control; when the material departs from the probe, the meter restores to the normal working condition to detect the changes of material level. 

                      Product Details:
                      ModelSD-YCO 1 SA-LM-200
                      SD-YC 71
                      (Explosion proof type)
                      Power Supply24 VAC/DC (Standard)
                      220 VAC, 110 VAC(Optional)
                      Contact Capacity220 VAC 5A, DPDT
                      Medium Temperature-10 °C~80°C (high temperature type:max 150° C)

                      View Complete details

                      get quote request a call back
                      Radar type Level Indicator Transmitter

                      Radar type Level Indicator Transmitter

                      Price on Request
                      Output Signal4~20 mA/HART
                      Ambient Temperature-40~+60
                      EnclosureIP-67
                      Repetition2 mm
                      Damping Period0~32 s adjustable
                      Power11~28.6 VDC (intrinsically-safe), 11~36 VDC (explosion proof)
                      Pressure25 kg/cm2 high pressureLess than and equal to MPa(i.e. 326 kg/cm2)
                      Load Resistance65 ohm
                      Data Updated30 ms
                      Humidity0~99% RH
                      By keeping track with the market development, we have been able to trade and supply a premium quality Radar Type Level Indicator Transmitter. Offered transmitter is designed and manufactured using exceptional quality raw material and highly developed technology at our vendor’s hi-tech manufacturing unit. In addition, this transmitter is obtainable in standard and customized options as per the particular requirements of the clients.

                      Features:
                      • Optimum performance
                      • Reliability
                      • Low maintenance cost
                      • Longer functional life

                      Product Details:
                      • Medium Density: normal temperature<=100, middle temperature 210, high temperature <=520
                      • Electric interface: default M 20 x 1.5, or as per customer request.
                      • Output accuracy: analogue:0.01 mA, Display: when measuring range <10 m Analog display is 1mm, when range >10 m is 10 mm.
                      • Precision: coaxial type 0.1% FS, other 5 mm
                      • Temperature influence: probe length change(-0.02%) as temperature change one centigrade User interface: 3 key+ LCD display
                      • Linearity: coaxial type/dual rod:<=0.1% probe length; Single rod:<=0.3% probe length
                      • Fault-diagnosis, warning: 3.6 mA, 22 mA, Hold

                      View Complete details

                      get quote request a call back
                      Tank Farm Transmitter

                      Tank Farm Transmitter

                      Price on Request

                      Product Brochure

                      Sensor Cable25 ft / 7.6 M coaxial
                      Power Input100-130 VAC 50/60 Hz, 7 watts maximum
                      SensorPZ 32 T, PVC and Teflon, 32 ft / 10 m range
                      OutputIsolated 4-20 Ma (1000 Ohm)
                      With our rich industry experience and knowledge, we are engaged in trading and supplying high quality Tank Farm Transmitter. Offered transmitter is designed and manufactured by our vendors utilizing quality approved raw material and advance technology in relevance to the industry standards. Also, our clients can avail this transmitter from us in certain specifications and can be customized as per their precise requirements.

                      Features:
                      • Enclosure: Watertight, dust tight NEMA 4 X (IP66) polycarbonate
                      • Programming: Built-in 3 button keypad, Password protected
                      • Calibration: Level, Range or Open Channel Flow
                      • Displays: Level/Flow values - large 4-digit LCD Menu/Status/Totalizer - 16-digit alphanumeric
                      • 3 relays: 5 ampere SPDT, programmable alarm and/or pump control modes, lead/lag pump
                      • Temperature compensation: Automatic
                      • Electrical surge protection: Sensor, AC power and 4-20mA output
                      • 1 PC software utilities disk
                      • 1 Manual: Installation and Operation


                          Additional Information:

                          • Item Code: TFT32

                          View Complete details

                          get quote request a call back
                          Fuel Oil Level Transmitter

                          Fuel Oil Level Transmitter

                          Price on Request
                          MaterialSS
                          Accuracy+/- 0.1%
                          Power Supply24 V DC
                          Range0-70380 mmH2O
                          With our rich industry experience and knowledge, we are engaged in trading and supplying high quality Fuel Oil Level Transmitter. Our vendors professional design and manufacture these transmitters utilizing exceptional quality raw material and modern technology. In addition, we offer this atta chakki in various specifications and can be customized according to the particular requirements of the clients.

                          Features:
                          • Superior performance
                          • Longer service life
                          • Durable finish
                          • User friendly

                          Applications:
                          • Diesel fuels
                          • Hydraulic oils
                          • Vegetable oils
                          • Chemical holding tanks
                          • MEK and other solvents
                          • Many other, non-conductive liquids

                          View Complete details

                          get quote request a call back
                          Hydrostatic Level Transmitter

                          Hydrostatic Level Transmitter

                          Price on Request
                          Accuracy0.25%FS standard
                          ApplicationIndustrial
                          Power Supply10~30 VDC, 0.5 V
                          Range0~1 mH2O-200 mH2O
                          We are known as the reputed organization in this field of operation, engaged in trading and supplying excellent quality Hydrostatic Level Transmitter. This transmitter is designed and manufactured by our vendor’s dexterous professionals using excellent quality raw materials and ultra-modern technology in consequence to the set industry norms. Offered transmitter is obtainable in various specifications to carry out the specific requirements of the clients

                          Features:
                          • Precise dimensions
                          • Compact design
                          • Sturdy construction
                          • High strength

                          View Complete details

                          get quote request a call back
                          Vibration Meter

                          Vibration Meter

                          Price on Request
                          Usage/ApplicationIndustrial
                          WeightUpto 900 g
                          CommunicationUSB2.0 Full Speed
                          Operation Temperature-10 deg C~ 50 deg C
                          StorageRAM 64M & Flash 1GB
                          We have gained immense recognition in the industry by trading and supplying quality assured Vibration Meter. This vibration meter is designed and manufactured using elevated quality raw material and contemporary technology underneath the direction of our vendors’ adroit professionals. Offered vibration meter is rigorously tested on assured quality parameters to ensure its consistency. Furthermore, we offer our clients this vibration master at industry leading price range.

                          Features:
                          • Compact design
                          • High strength
                          • Low maintenance

                          View Complete details

                          get quote request a call back
                          RF Admittance Point Level Switch

                          RF Admittance Point Level Switch

                          Price on Request
                          Power Consumption1.9 VA
                          Mains Voltage230/110 V AC (+/-15%), 50 Hz or 18-55 V DC or 65 to 265 V AC.
                          Switch Status DisplayGreen LED shows Normal, Red LED shows alarm, Yellow
                          Ambient Temperature0 deg C to +60 deg C
                          We are a distinguished trader and supplier of a wide range of RF Admittance Point Level Switch. Offered switches are designed and manufactured utilizing top quality raw material and latest technology at our vendors unit under the administration of skilled professionals. Thoroughly tested on varied parameters to find out its reliability, these switches are available at most competitive price range.

                          Features:
                          • High performance
                          • Less maintenance
                          • Energy efficiency
                          • Low running cost

                          The salient features of this level measuring instrument are as follow:

                          • Three Element Coat Guard Technology
                          • Can be configured either for High or Low Level point switching
                          • Ignores material build-up on the probe
                          • Suitable for the highly dusty environment
                          • High Reliability
                          • Fast and Easy Installation Simple Calibration
                          • Field selectable operation logic
                          • Provides economical solutions
                          • Various models not required

                          The specifications of these point level switch are as follow:
                          Switching Unit:
                          • Housing: Aluminum, weather proof, powder coated. Integral with The probe/ suitable for back panel mounting
                          • Output: 1/2 sets of potential free c/o contacts rated at 5 amps, 230 V AC for non-inductive loads
                          • Switching delay: Continuously adjustable From 1 to 20 sec. probe Free or probe covered (Optional)
                          • Safety operation: Field selected switch over for min. or max. (FSL/FSH) switching points
                          • LED shows power on condition

                          Coat Guard Sensing Probe:
                          • Mounting: Screwed 1 ½ BSP (standard) Or Flanged (optional)
                          • Sense rod: Stainless steel
                          • Shield: Stainless steel
                          • Insulation: PTFE (standard) other on request and as per application.
                          • Operating Temp: 100 deg for the integral switching vessel unit., 225° C for remote switching unit

                          View Complete details

                          get quote request a call back
                          Doppler Flow Switch

                          Doppler Flow Switch

                          Price on Request
                          Power Supply115/230 VAC or 24 VDC
                          OutputsForm C Relay, COM, NO, NC
                          Accuracy+/- 2% of Rate for velocities
                          Repeatability+/- 2%
                          Features:
                          • Easy Calibration
                          • Accurate and Repeatable
                          • 5 amp DPDT Control Relay
                          • Adjustable ON/OFF Set-Points
                          • Adjustable Time Delay
                          • Relay Status LED
                          • Intrinsic Safety Option


                          Doppler Flow Switch Specifications:

                          Scope:

                          • This Specification Covers A Non-Intrusive, Ultrasonic Doppler-Type Flow Switch As Manufactured By Grey line Instruments Inc., Massena, New York / Long Sault, Ontario. The Instrument Shall Provide For Flow Control At Adjustable Flow Velocities.


                          General:

                            Each Portable Transit Time Flow Meter Shall Have The Following Design Features And Engineering Specifications:


                              Performance Specifications:

                              • The Flow Switch Shall Operate With A Strap-On Flow Sensor Mounted Externally On Carbon Steel, Stainless Steel, Ductile Iron, Copper, FRP, PVC, Abs, Or Cement Lined Pipe, And On Liquids With Entrained Particles Or Gases Of 100 Microns Or Larger And Minimum Concentrations Of 75 Ppm
                              • The Control On And Off Set-Points Shall Be Independently Adjustable For Flow Rates Between 0.25 Ft/Sec (0.076 M/Sec) And 10 Ft/Sec (3 M/Sec), In Pipes 1/2" (12.5 Mm) Id Or Larger


                              Transducer (Sensing Element):

                              • The Flow Sensor Shall Be Single-Head, Ultrasonic In A Stainless Steel Housing. It Shall Be Installed On The Outside Of A Pipe Without Interrupting Flow. The Sensor Shall Be Capable Of Continuous Operation At Temperatures From -40°F To 200°F (-40°C To 93°C), And To Withstand Accidental Submersion Pressures To 10 Psi. Manufacturer Recommended Coupling Compound And Stainless Steel Pipe Clamp Shall Be Included
                              • Shall Include 20 Ft (6M) Shielded Coaxial Cable Pair With Waterproof, Potted Bond To The Sensor Head.
                              • Shall Be Capable Of Extending Sensor Cable Up To 500 Ft (152 M), Without Adjustment, And With No Reduction In Performance Or Signal Strength
                              • Shall Be Designed For Maximum RFI Rejection, And Include Automatic High Voltage Bleeds For Nearby Lightning Strikes


                                Additional Information:

                                • Item Code: DFS-II

                                View Complete details

                                get quote request a call back
                                Conductivity Point Level Switch

                                Conductivity Point Level Switch

                                Price on Request
                                Response Time0.5 Sec
                                Switch Status DisplayGreen LED shows Normal,Red LED shows alarm.
                                Ambient Temperature0 deg C to +60 deg C
                                Power Consumption1.9 VA
                                With our rich industry experience, we trade and supply a supreme quality range of Conductivity Point Level Switch. These switches are designed and manufactured utilizing finest quality raw material and latest techniques at our vendors end. Stringently tested on diverse parameters by quality controllers to make certain its dependability, we provide these switches to our esteemed clients in different specifications as per their requirements.

                                Product Details:
                                • No moving part, free of maintenance.
                                • No special cable required for signal transmission, Economical to install.
                                • Long cable connection permissible between probe and evaluation unit.
                                • AC on probes for prevention of electrolytic deterioration of electrodes.
                                • Low voltage on probe for operational safety.
                                • Variety of control functions and installation system available, beside single point switching.
                                • 1 Two point action for automatic pump control.
                                • 2 Two point independent switching.
                                • 3 Three point switching, two points with pump control logic and one independent point.
                                • 4 Four point switching having two-pump control logic.
                                • 5 Multichannel -4 point independent switching available for various process conditions
                                • Variety of probes available for various process conditions.

                                Technical Specifications (Standard):
                                Switching Unit:
                                • Housing: Aluminum, weather proof, powder coated. for back panel mounting /DIN Rail mounting
                                • Cable entry: - As per housing option.
                                • Mains Voltage: 230/110 V AC (+/-15%), 50 Hz or 24 V DC ,Or 65 to 265 V Ac
                                • Output: 1 / 2 sets of potential free c/o contacts rated at 10 amps, 250 V AC for non-inductive loads.
                                • Safety operation: Field selected switch over for min. or max. (FSL/FSH) switching points.

                                View Complete details

                                get quote request a call back
                                TDR Level Transmitter

                                TDR Level Transmitter

                                Price on Request
                                Measuring Range30 m
                                Output Signal4-20 mA
                                Accuracy+/-3 mm
                                Power Supply24 V DC/220 V AC
                                We are an unparalleled name, engaged in trading and supplying a premium quality TDR Level Transmitter that is widely used in various industries like food processing, chemical, pharmaceutical, and many more. Offered transmitter is designed and manufactured using finer quality raw material, procured from the authentic vendors of the market. Also, we offer this transmitter to our precious client’s at most competitive price range.

                                Features:
                                • Precise size
                                • High durability
                                • Fine finish
                                • Easy installation

                                View Complete details

                                get quote request a call back
                                Boot Level Switch

                                Boot Level Switch

                                Price on Request
                                Operating Temperature-40 deg C~+135 deg C
                                Contact CapacityAC 220 VA,DC 50 W
                                Medium DensityMore than 0.45 g/cm3
                                WeightUpto 500 gm
                                Fostered with immense years of industry experience and market understanding, we are trading and supplying an excellent quality Boot Level Switch. Offered level switches are designed and manufactured using premium quality raw material and advance techniques at our vendor’s hi-tech manufacturing unit. In addition, our clients can avail these level switches from us at industry leading price range.

                                Features:
                                • Sturdy structure
                                • Compact design
                                • Easy installation
                                • Durability

                                View Complete details

                                get quote request a call back
                                Diesel Tracking System

                                Diesel Tracking System

                                Price on Request
                                WeightUpto 325 g
                                UseAutomotive
                                Power12 V/24 V
                                ModuleGPS and GSM
                                Leveraging on our vast industry experience, we are trading and supplying our clients a finest quality Diesel Tracking System. These systems are designed and assembled utilizing finest quality factor inputs and advance technology by our vendors. Meticulously tested on certain parameters to ascertain their reliability, offered systems are available in different specifications and can be customized as per the specific requirements of the clients.

                                Features:
                                • Smart Remote Monitor.
                                • Avoids Pilferage of fuel.
                                • Built in Flow meter.
                                • Running Hours Meter (KWH Optional).
                                • SMS Facility for real time fuel level.
                                • Low level fuel Alarm (SMS Facility).
                                • Maintenance Schedules (SMS Facility).
                                • Data Transfer.
                                • Software.
                                • Easy to install.

                                Benefits:
                                • Today the market demand for effective fuel management derives from the requirement of generator operators to control and monitor fuel usage by generators. Fuel theft and unauthorized use can cause significant financial losses. More careful monitoring of fueling and generator performance can also helps in detecting mechanical and operational problems in generator thereby improving efficient fuel use.
                                • In response to these market demands, we have introduced DTS--12 (Diesel Tracking System) product that use wireless GSM Technology which enables generator operators and owners to monitor and control generator fuel usage and efficiency.
                                • The system records the quantity of fuel filled, fuel consumption of the generator, running hours and maintenance schedules.
                                • Whenever the fuel is filled in the generator the system sends an SMS to the Programmed mobile phones like the Quantity of fuel filled, Present level in the tank, Quantity consumed from the last fueling, Hours run from the last fueling, No of power outages and Fuel and Running Hours Totalizers.

                                View Complete details

                                get quote request a call back

                                EXPLORE MORE CATEGORIES